Zareba G752 Installation Manual - page 27
27
Step 5
Replace the battery access cover.
Step 6
Check to see that the DIP switch settings match by
pressing the transmitter button. If the gate moves, the
DIP switch settings match.
If the gate does not move, adjust the transmitter DIP
switch settings to match the RF receiver DIP switch set-
tings. Then press the transmitter button to verify that
the gate moves.
Step 7
Replace the RF receiver box cover.
Setting The Gate’s Closed Limit Position
Next you must set the gate opener’s CLOSED limit set-
ting. (limit setting: the desired stopping point for your
gate) This will vary depending on if you are using a
pull-to-close (standard set up) or push-to-open (alterna-
tive set up, see page 22) arrangement for your opener.
Pull-to-Close Closed Limit Setting
Step 1
Turn the power ON to energize the system.
Step 2
Make sure both gates are in the fully open position.
Press the transmitter button and the gates will begin to
close. Be prepared to stop the gates when the desired
limit has been reached by the first gate opener
(actuator) that closes first.
Step 3
If Opener 2 was the first gate to close, set Dual Mode
DIP switch 4 to the ON position. If Opener 1 was the
first gate to close, set Dual Mode DIP switch 4 to the
OFF position. Then press and hold the SET LIMIT button
for two seconds (fig. 41). The STATUS light will turn on
momentarilly, then turn off.
Figure 41
Step 4
Press the button of the transmitter and the gates should
move to the fully open position. The first gate opener’s
(actuator) closed position is now set for the opener that
closed first.
Step 5
Now press the transmitter button again. Your gates
should begin to close. The opener that closes first will
stop at the closed limit position you programmed in the
previous steps. The other gate will continue to close
until you press the transmitter button again. The sec-
ond gate should close firmly up to the first gate without
excessive pressure against the first gate.
Step 6
If Opener 2 was the second gate to close, set Dual
Mode DIP switch 4 to the ON position. If Opener 1 was
the second gate to close, set Dual Mode DIP switch 4 to
the OFF position. Then press and hold the SET LIMIT
button for two seconds. The STATUS light will turn on
momentarilly, then turn off.
Step 7
Using the handheld transmitter return the gates to the
fully open position. Both gates’ closed position stops
are now set.
Step 8
Again, using the handheld transmitter close the gates to
verify they meet the desired location. Note: If the gates
did NOT reach the desired limit proceed to Step 9.
Step 9
Clearing the closed limit setting for Opener 1:
a) Return the gate to the fully open position.
b) Set Dual Mode DIP switch 4 to the OFF position.
c) Press and hold the SET LIMIT button for five sec-
onds. When the green STATUS light comes on, the
closed limit setting has been reset to factory
defaults.
Clearing the closed limit setting for Opener 2:
a) Return the gate to the fully open position.
b) Set Dual Mode DIP switch 4 to the ON position.
c) Press and hold the SET LIMIT button for five sec-
onds. When the green STATUS light comes on, the
closed limit setting has been reset to factory
defaults.