Zebra SAC400-1000CR User manual
Introduction
The SAC400-1000CR Single Slot Battery Charger charges the ES400
1540 mAh and 3080 mAh batteries.
Charging a Battery
To charge a battery:
1. Open the cover.
2. Insert the battery into the charger slot. Note the correct position of
the battery contacts.
1. Close the cover and ensure that it snaps closed.
2. Connect the microUSB end of the USB Rapid Charge Cable or
Auto Charge Cable to the microUSB connector on the bottom of the
charger.
3. Connect the other end of the cable to the power supply, host
computer or cigarette lighter socket.
The LED indicates the status of the battery charging. The 1540 mAh
battery fully charges in less than three hours and the 3080 mAh battery
fully charges in less than six hours.
Removing the Battery
To remove the battery:
1. Disconnect the cable from the bottom of the charger.
2. Open the cover.
3. Pull the battery out of the charger.
Regulatory Information
This guide applies to Model Number SAC400-1000.
All Zebra devices are designed to be compliant with rules and
regulations in locations they are sold and will be labeled as required.
Local language translations are available at the following website:
http://www.zebra.com/support.
Any changes or modifications to Zebra equipment, not expressly
approved by Zebra could void the user’s authority to operate the
equipment.
For use only with Zebra approved and UL Listed mobile computers.
Zebra approved and UL Listed accessories and/or Zebra approved and
UL Listed/Recognized battery packs.
Declared maximum operating temperature 40ºC.
Power Supply
Use ONLY a LISTED, Type no. 86-124306 (5 VDC, 1.2 A) or PWRS-
124306 (5 VDC, 1.2 A), direct plug-in power supply, marked Class 2 or
LPS (IEC60950-1, SELV). Use of alternative power supply will
invalidate any approvals given to this unit and may be dangerous.
Batteries
Taiwan - Recycling
EPA (Environmental Protection Administration)
requires dry battery producing or importing
firms in accordance with Article 15 of the Waste
Disposal Act are required to indicate the
recycling marks on the batteries used in sales,
giveaway or promotion. Contact a qualified Taiwanese recycler for
proper battery disposal.
Battery Information
Use only Zebra approved batteries. Accessories which have battery
charging capability are approved for use with the following battery
models:
•
Zebra 82-118523-xx (3.7 VDC, 1540 mAh)
•
Zebra 82-118524-xx (3.7 VDC, 3080 mAh)
Zebra rechargeable battery packs are designed and constructed to the
highest standards within the industry.
However, there are limitations to how long a battery can operate or be
stored before needing replacement. Many factors affect the actual life
cycle of a battery pack, such as heat, cold, harsh environmental
conditions and severe drops.
When batteries are stored over six (6) months, some irreversible
deterioration in overall battery quality may occur. Store batteries at half
of full charge in a dry, cool place, removed from the equipment to
prevent loss of capacity, rusting of metallic parts and electrolyte
leakage. When storing batteries for one year or longer, the charge level
should be verified at least once a year and charged to half of full
charge.
Replace the battery when a significant loss of run time is detected.
Standard warranty period for all Zebra batteries is one year, regardless
if the battery was purchased separately or included as part of the
mobile computer. For more information on Zebra batteries, please visit:
http://www.zebra.com/batterybasics
Battery Safety Guidelines
•
The area in which the units are charged should be clear of debris
and combustible materials or chemicals. Particular care should be
taken where the device is charged in a non commercial
environment.
•
Follow battery usage, storage, and charging guidelines found in the
user's guide.
•
Improper battery use may result in a fire, explosion, or other
hazard.
•
To charge the mobile device battery, the battery and charger
temperatures must be between +32 ºF and +104 ºF (0 ºC and
+40 ºC)
•
Do not use incompatible batteries and chargers. Use of an
incompatible battery or charger may present a risk of fire,
explosion, leakage, or other hazard. If you have any questions
about the compatibility of a battery or a charger, contact Zebra
support.
•
To enable authentication of approved batteries, as required by
IEEE1725 clause 10.2.1, the batteries contain a Zebra hologram.
Do not install any battery without checking it has the Zebra
authentication hologram.
•
Do not disassemble or open, crush, bend or deform, puncture, or
shred.
•
Severe impact from dropping any battery-operated device on a
hard surface could cause the battery to overheat.
•
Do not short circuit a battery or allow metallic or conductive objects
to contact the battery terminals.
•
Do not modify or remanufacture, attempt to insert foreign objects
into the battery, immerse or expose to water or other liquids, or
expose to fire, explosion, or other hazard.
LED Status
Description
Off
Indicates that the charger is not connected
to power and the battery is not charging.
Slow Blinking Green
(1 blink every 2 seconds)
Indicates that the battery is charging.
Solid Green
Indicates that the battery is fully charged.
Fast Blinking Red
(2 blinks/second)
Indicates charging error.
LED Indicator
Battery
Contacts
NOTE
USB wall chargers and USB auto chargers must supply
a minimum of 750 mA.
caution
Do NOT attempt to charge damp/wet batteries.
All components must be dry before connecting
to an external power source.