Zehnder Rittling ComfoAir 160 User Manual

Summary of ComfoAir 160

  • Page 1

    Comfoair 160 user manual.

  • Page 2

    En - ii all rights reserved. This manual has been compiled with the utmost care. The publisher cannot be held liable for any damage caused as a result of miss- ing or incorrect information in this manual. In case of dis putes the dutch version of these instructions will be binding..

  • Page 3: Table of Contents

    Iii - en table of contents preface ............................................................................................................................................................ 1 1 introduction ..............................................................................................

  • Page 4

    En - iv en - iv.

  • Page 5: 1  Introduction

    1 - en 1 - en preface carefully read this manual before use. This manual provides all the information required for safe and optimal installation and maintenance of the com- foair 160. It is also intended as a reference for servicing, so that this can be carried out in a responsible manner. The devic...

  • Page 6

    En - 2 en - 2 1.2 safety 1.2.1 safety regulations always comply with safety regulations in this manual. Non-compliance with the safety regulations, warnings, notes and instructions in this manual can cause personal injury or damage to the comfoair. • the comfoair may only be installed, connected, re...

  • Page 7: 2  For The User

    3 - en 3 - en 2 for the user congratulations, you are the owner of a comfoair 160, a heat recovery unit from zehnder. We wish you lots of comfort. 2.1 glossary the comfoair features: • balanced ventilation; • heat recovery; • bypass for free cooling; • frost protection; • open fi re programme; • wir...

  • Page 8

    En - 4 2.1.7 enthalpy (optional) it is possible to fit the comfoair with an enthalpy ex- changer. An enthalpy exchanger helps to regulate hu- midity levels in the dwelling. In addition to heat recovery, the enthalpy exchanger also ensures moisture recovery. Moisture recovery means that moisture from...

  • Page 9

    5 - en setting the ventilation using 3-position switch(es) a 3-position switch can be used to set 3 different ventila- tion positions. • position 1 g low. - use for low ventilation levels. • position 2 normal. - use when present and no extra ventilation is needed. • position 3 high. - use during coo...

  • Page 10

    En - 6 day and time actual ventilation setting automatic or manual ventilation signal to replace internal (i) or external (e) filter supply air and/or exhaust air open or closed bypass open [ ] or closed. Actual temperature, selection or setting this button allows you to switch to the highest ventil...

  • Page 11

    7 - en 2.3 operating the cc ease panel the cc ease panel is used for the following: • reading and setting the day and time; • reading and setting the comfort temperature; • reading and setting the ventilation volume; • switching boost on; • switching the supply and exhaust fan on/off; • setting a pe...

  • Page 12

    En - 8 setting the ventilation volume the ventilation volume can also be set manually by in- creasing or decreasing it. A total of 4 ventilation volumes/ levels can be set. They are: • setting a ¨ absent. - use when house is unoccupied. At setting a, the house is ventilated using the minimum prescri...

  • Page 13

    9 - en 3. Press " " again (third time) to switch the supply and exhaust fans on again. Bear in mind that switching off the supply or exhaust fan will temporarily immobilize your balanced ventilation system. 2.3.6 setting a personal ventilation programme the comfoair has a factory default ventilation...

  • Page 14

    En - 10 the user can only access p menus p1, p2 and p9 to set additional programmes. The remain- ing p menus (p3 to p8) are for use by the in- staller only. Accessing the p menus 1. Press " " and " " for two seconds simultane- ously. - wait until "p 2" appears on the display. 2. Select the desired p...

  • Page 15

    11 - en 2.3.8 p menus for the user menu p1 ¨ status of programmes status sub- menu description activated p11 is menu 21 currently active? Yes (1) / no (0) p12 is menu 22 currently active? Yes (1) / no (0) p13 is menu 23 currently active? Yes (1) / no (0) p14 is menu 24 currently active? Yes (1) / no...

  • Page 16

    En - 12 time delay values sub-menu description minimum maxi- mum general reset p26 note: only applies to systems fit- ted with an rf switch. Overrun timer for ventilation setting 3 " using ". • after pressing " " continuously (> 2 sec.), the comfoair will switch to the high setting for ‘x’ minutes a...

  • Page 17

    13 - en 2.4 maintenance by the user the following maintenance must be carried out by the user: • replacing the filters; • cleaning the valves (in the dwelling). A concise explanation of these maintenance activities is given in the paragraphs below. Failure to carry out (periodic) maintenance on the ...

  • Page 18

    En - 14 the installer will have set all the valves to ensure the op- timum performance of the ventilation system. Therefore, do not change the setting of the valves. After cleaning, make sure that all valves are placed back with the same setting (and in ex- actly the same ventilation hole in the wal...

  • Page 19

    15 - en 3 eec declaration of conformity zehnder group nederland b.V. Lingenstraat 2 8028 pm zwolle-nl tel.: +31 (0)38-4296911 fax: +31 (0)38-4225694 company register zwolle 05022293 eec declaration of conformity machine description : heat recovery units: comfoair 160 series complies with the followi...

  • Page 20

    Zehnder group nederland b.V. Lingenstraat 2 8028 pm zwole nederland tel.: (038) 429 69 11 fax.: (038) 422 56 94 internet: www.Jestorkair.Nl e-mail: info@jestorkair.Nl © zehnder group nederland b.V . 849050968-0112.