  • Page 1

    801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 page 1 of 28 hydrotap g4 user guide ® • tap operation..................(pages 2-10) • lcd screen & menu .......(pages 11-22) • maintenance.................... (pages 23-26) • home menu icons............(page 27) • contact details........

  • Page 2: Tap Safety

    Page 2 of 28 801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 the safety lock feature is provided to prevent boiling water flowing if the hot lever is inadvertently operated. This function can be activated and deactivated from either the tap or from the touch screen display (located...

  • Page 3: Elite Tap:

    801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 page 3 of 28 elite tap: the elite tap uses touch sensitive controls, to dispense boiling, chilled and sparkling water. When operating the tap, ensure the touch surface is dry as moisture may interfere with the sensor touch control. Th...

  • Page 4: Tap Functions

    Page 4 of 28 801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 3. Tap functions mixertap: lifting the handle up will decrease the flow rate and lowering the handle will increase the flow rate. Raise the handle all the way up to turn the tap off. When the handle is moved towards the b...

  • Page 5: Tap Operation

    801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 page 5 of 28 arc/cube tap 3. Tap operation hydrotap classic and all-in-one taps: depressing the “blue” lever allows the dispensing of chilled water. Pulling forward the blue lever allows the tap to operate in a “no-touch” mode. Water ...

  • Page 6: Tap Operation

    Page 6 of 28 801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 3. Tap operation to dispense boiling water: (with the safety on) hydrotap classic: depress the red lever, while simultaneously covering the safety lock button with a second finger. These two actions need to occur simultan...

  • Page 7: Tap Operation

    801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 page 7 of 28 tap operation hydrotap classic and all-in-one taps: depressing both the ‘red’ an d the ‘blue’ levers allows the dispensing of sparkling water. Pulling forward both levers allows the tap to operate in a in a “no-touch” mod...

  • Page 8: Tap Lights

    Page 8 of 28 801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 tap lights warning: (all) flashing warning light: when the indicator light flashes fast and continuous, a system fault has occurred. Check for details on the faults screen. If unable to rectify, call a qualified service a...

  • Page 9: Filter Light:

    801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 page 9 of 28 filter light: classic; elite & aio filter light off: this indicates the filter is operating within its normal specified lifespan. Filter change light flashing slowly: the light will flash slowly when the filter is due for...

  • Page 10

    Page 10 of 28 801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 light intensity varies from site to site, therefore it is recommended that a re-calibration be performed at the time of the installation. All direct natural sun light must be shaded from the hydrotap, during the calibrat...

  • Page 11: Lcd Screen

    801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 page 11 of 28 note: as an energy saving feature, the home screen will turn off after 5 minutes of non use. Touching the darkened lcd panel will reactivate the home screen. Zenith hydrotap g4 introduces a ‘touch’ screen for easy setup ...

  • Page 12: Lcd Screen Menu

    Page 12 of 28 801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 3 lcd screen menu main menu sub menu sub menu options section language • english • deutsch a • product info • system faults • event log • product serial no. • lists b information installation • filter flush • filter rese...

  • Page 13

    801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 page 13 of 28 a set language b system information in this section, you can find product information, system faults and check the filter logs of your product. Lcd screen operation - section a lcd screen operation - section b 1. Press [...

  • Page 14: C           Install

    Page 14 of 28 801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 c install once your zenith hydrotap g4 unit has been installed, select the install menu to configure the system settings for your product. 1. - filter flush lcd screen operation - section c open position closed position ...

  • Page 15: 2. - Filter Reset

    801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 page 15 of 28 after replacing the filter, the counters should be reset 2. - filter reset lcd screen operation - section c 1. Press the [menu] button for main menu. 2. Press the [install] button. 3. Press the [filter reset] button. 4. ...

  • Page 16: 6 - Lux Sensor Calibration

    Page 16 of 28 801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 lcd screen operation - section c this section is reserved for service technicians only note : in australia call a licensed electrician, plumber,or zenith office on 1800-638-633, for assistance, service, spare parts, or e...

  • Page 17: E            Security

    801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 page 17 of 28 e security the zenith hydrotap g4 allows the appliance coordinator to set up a pass- word to protect against users changing the preferred system settings. To set a password 1. Press [menu] button for main menu. 2. Press ...

  • Page 18: Settings

    Page 18 of 28 801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 g settings 3. Lcd screen operation - section g g i nstructions 1. Press [menu] button for main menu. 2. Press [settings] button. 4. Then enter your 4-digit password. 1. Press [menu] button for main menu. 2. Press [settin...

  • Page 19: Filter

    801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 page 19 of 28 1. Press [menu] button for main menu. 2. Press [temperature] button. 3. To adjust the temperature, press the relevant temperature button and then use the up and down arrows. 3. Lcd screen operation - section g t to edit ...

  • Page 20: Energy Modes

    Page 20 of 28 801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 3. Lcd screen operation - section g this mode allows the hydrotap to enter into energy saving mode. There are two options available: ‘sleep’ mode and ‘on/off’ mode. To activate the sleep mode: 1. Press [menu] button for ...

  • Page 21

    801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 page 21 of 28 lcd screen operation - section g 1. Press group 1 or group 2 option 2. Press button to enable / disable group set. When the enable box is ticked, this allows each individual day to have an “on/off” time. 3. Press [on/off...

  • Page 22: Safety

    Page 22 of 28 801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 safety lcd screen operation - section g b c a c * to set the tap safety setting: • press [menu] button for main menu. • press [setting] button. • press [safety] button. • press button - yes to allow the safety setting to...

  • Page 23: To Change The Filter:

    801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 page 23 of 28 to change the filter: (see also section c) • open the door of the under sink unit. • relieve system pressure via the filter flush stop cock, a quick open and close will do. Use the bucket to catch the discharge. • grasp ...

  • Page 24: Filter Maintenance

    Page 24 of 28 801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 filter maintenance air inlet filter the zenith hydrotap air filter is conveniently located on the outside of the condenser. The filter screen is a sliding fit in the plastic housing on the side of the under sink unit. Th...

  • Page 25: 2.6Kg Gas Bottle Change

    801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 page 25 of 28 2.6kg gas bottle change 1. Turn the co 2 bottle, black knob, off (clockwise). 2. Turn the regulator, grey knob, all the way out (anti clockwise). 3. Dispense sparkling water for 30 seconds, until the water flow is free o...

  • Page 26: Cleaning

    Page 26 of 28 801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 cleaning general cleaning do not use strong, corrosive, spray or abrasive cleaners. Clean with a soft damp cloth and mild soap. Under sink units must never be located near, or cleaned with water jets. Avoid using airborn...

  • Page 27: Home Menu Icons

    801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 page 27 of 28 home menu icons safety switch is locked. The hydrotap will not dispense any boiling water. See page 2 for safety switch operation safety switch is unlocked. Boiling water may be dispensed. See page 5 for tap operation de...

  • Page 28: Contact Details

    Page 28 of 28 801912nz - g4 bcs, bcsha commercial user guide - aug 2015 - v2.00 the terms “zenith” and “hydrotap” are registered trade marks of zip heaters (aust) pty ltd. Zenith products described in this publication are manufactured under one or more of the following patents: au675601, au637412, a...