1 Source S1-TBEU22P7S Installation Instructions Manual

Manual is about: Heat/Cool & Heat Pump 7-Day Programmable Digital Thermostat

Summary of S1-TBEU22P7S

  • Page 1

    Model commercial s1-tbeu22p7s hvac service parts tm installation instructions installation instructions backlit display use with most heat pump systems: 2-heat, 2-cool digital thermostat digital thermostat heat/cool & heat pump 7-day programmable heat/cool & heat pump 7-day programmable • stages: 2-...

  • Page 2: Contents

    Page 2 contents page # remove old thermostat safety warnings preparation warranty test operation troubleshooting wire connections installation instructions s1-tbeu22p7s.

  • Page 3: Safety Warnings

    Caution follow installation instructions carefully. Disconnect power to the heater - air conditioner before removing the old thermostat and installing the new thermostat. Warning page 3 safety warnings p/n s1-tbeu22p7s installation instructions this device complies with part 15 of the fcc rules. Ope...

  • Page 4: Preparation

    Page 4 these tools will be required: flat blade screwdriver wire cutter & stripper make sure your heater/air conditioner is working properly before beginning installation of the thermostat. Carefully unpack the thermostat. Save the screws and instructions. Proper installation of the thermostat will ...

  • Page 5: Remove & Replace

    Remove the cover of the old thermostat. If it does not come off easily check for screws. Loosen the screws holding the thermostat base or subbase to the wall, and lift away. Disconnect the wires from the old thermostat. Tape the ends of the wires as you disconnect them, and mark them with the letter...

  • Page 6: Wire Connections

    Page 6 wire connections if the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below or the wiring diagrams that follow. Thermal insulating sheet fig. 1 wire slots a label is provided on the backplate that prevents drafts originating inside t...

  • Page 7: Sample Wiring Diagrams

    Hp o elec jp 1 jp 2 jp 3 gas gas b page 7 sample wiring diagrams 5 conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment. Fan g compressor y 5 wire, single stage heat pump (o reversing valve) residential heat pumps, split systems & package units, with no auxiliary heat. Inst...

  • Page 8: Sample Wiring Diagrams

    Page 8 sample wiring diagrams 6 conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment. Fan g power r w2 auxiliary heat compressor y reversing valve o 6 wire, single stage heat pump with auxiliary heat (o reversing valve) residential heat pumps, split systems & package units,...

  • Page 9: Sample Wiring Diagrams

    Page 9 sample wiring diagrams 7 conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment. Fan g power r w2 auxiliary heat compressor y reversing valve o 7 wire, two stage heat pump with auxiliary heat (o reversing valve) residential heat pumps, split systems & package units, wi...

  • Page 10: Sample Wiring Diagrams

    Page 10 sample wiring diagrams 5 conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment. Fan g compressor y 5 wire, single stage gas furnace residential gas heat, electric cool, split systems & package units. Installation instructions model : s1-tbeu22p7s made in china lis te...

  • Page 11: Sample Wiring Diagrams

    Page 11 sample wiring diagrams 6 conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment. Fan g power r w2 auxiliary heat compressor y installation instructions model : s1-tbeu22p7s made in china lis ted 4z95 24v . 60hz nec class 2 c r y1 w1/o/b g w2 y2 enclosed energy man age...

  • Page 12: Sample Wiring Diagrams

    Page 12 sample wiring diagrams 7 conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment. Fan g power r w2 auxiliary heat compressor y installation instructions model : s1-tbeu22p7s made in china lis ted 4z95 24v . 60hz nec class 2 c r y1 w1/o/b g w2 y2 enclosed energy man age...

  • Page 13: Sample Wiring Diagrams

    Page 13 sample wiring diagrams 5 wire, single stage electric heat residential electric heat units with a separately controlled fan. Installation instructions elec gas jp 1 jp 2 jp 3 o b hp gas 5 conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment. Fan g compressor y model ...

  • Page 14: Test Operation

    Page 14 turn on the power to the hvac unit. Test operation two stage operation - the 2nd stage on the thermostat, press the mode button until heat is displayed. Press the cooler or warmer button until the set temperature is 10 degrees above room temperature. The hvac unit should energize in the heat...

  • Page 15: Test Operation

    Page 15 test operation on the thermostat, press the mode button until off is displayed. Press the fan button until fan on is displayed.The fan should turn on and run continuously. On the thermostat, press the mode button until cool is displayed. Press the cooler or warmer button until the set temper...

  • Page 16: Trouble Shooting

    Page 16 trouble shooting installation instructions symptom: the cooling does not attempt to turn on. Cause: the cooling setpoint is set too high or the thermostat is not in the cool mode. Section in the owner’s manual to: lower the cooling setpoint place the thermostat into the cool mode remedy: con...

  • Page 17: Warranty

    Page 17 warranty one-year warranty - this product is warranted to be free from defects in material and workmanship. If it appears within one year from the date of original installation, whether or not actual use begins on that date, that the product does not meet this warranty, a new or remanufactur...