1 Source S1-TBEU22P7S Installation Instructions Manual - Test Operation
Page 15
Test Operation
On the thermostat, press the Mode button until
OFF is displayed. Press the Fan button until
Fan On is displayed.The fan should turn on
and run continuously.
On the thermostat, press the Mode button
until COOL is displayed. Press the
COOLER or WARMER button until the set
temperature is 10 degrees below room
temperature. The HVAC unit should
energize in the cooling mode
(page 7 of the
Owner’s Manual)
.
INSTALLATION INSTRUCTIONS
TWO STAGE OPERATION - The 2nd stage
Heat or Cool
Setpoint
Deadband
Deadband
db 1
db 2
(adj. 1-6 )
1st Stage
turn on
2nd Stage
turn on
Heating
(non-adj. 2 )
Deadband
db 1
(adj. 1-6 )
1st Stage
turn on
Cooling
Deadband
db 2
(non-adj. 2 )
2nd Stage
turn on
of cooling is turned on when the room
temperature is equal to or greater than:
the setpoint plus the 1st stage deadband
(one degree, adjustable), plus the 2nd
stage deadband (two degrees, non-
adjustable).
Note: You may need to wait up to five minutes
for cooling to energize due to the compressor
lockout feature.
S1-TBEU22P7S