2N Helios Force Installation Manual

Other manuals for Helios Force: Installation Manual, Installation Manual
Manual is about: Door Access Intercom

Summary of Helios Force

  • Page 1

    Www.2n.Cz version 2n ® helios force/safety door access intercom installation manual 1.0.0

  • Page 2: Content

    The 2n telekomunikace a.S. Is a czech manufacturer and supplier of telecommunications equipment. The product family developed by 2n telekomunikace a.S. Includes gsm gateways, private branch exchanges (pbx), and door and lift communicators. 2n telekomunikace a.S. Has been ranked among the czech top c...

  • Page 3: Content

    Content 1. Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1 product description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.2 upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Page 4: 1. Product Overview

    4 2n telekomunikace a.S., www.2n.Cz ® 1. Product overview in this section, we introduce the and products, 2n helios ® force 2n helios ® safety outline its application options and highlight the advantages following from its use. Here is what you can find in this section: 1.1 product description 1.2 u...

  • Page 5: 1.1 Product Description

    5 2n telekomunikace a.S., www.2n.Cz ® 1.1 product description basic features 2n helios force/safety ® is a highly resistant and reliable door access intercom provided with a lot of useful above-standard functions. Can 2n helios force/safety ® work as a standard or emergency door access intercom for ...

  • Page 6: 1.2 Upgrade

    6 2n telekomunikace a.S., www.2n.Cz ® 1.2 upgrade the manufacturer reserves the right to modify the product in order to improve its qualities. Version changes 1.0 –.

  • Page 7: Basic Units

    7 2n telekomunikace a.S., www.2n.Cz ® 1.3 components and associated products basic units part no. 9151201-e 2n helios force ® 1 button part no. 9151201k-e 2n helios force ® 1 button with keypad part no. 9151204-e 2n helios force ® 4 buttons part no. 9152101-e 2n ® helios safety 1 button is designed ...

  • Page 8: Electric Locks

    8 2n telekomunikace a.S., www.2n.Cz ® part no. 9151001 brick flush mounting box part no. 9151002 plasterboard flush mounting box part no. 9152000 mounting frame orange aluminum gsm and voip connection accessories part no. 501303e gsm gateway easygate part no. 91341711e analogue/voip gateway electric...

  • Page 9: Other Accesories

    9 2n telekomunikace a.S., www.2n.Cz ® other accesories part no. 91341481e 12 v / 2 a adapter note: ac power supply is not applicable..

  • Page 10: 1.4 Terms and Symbols

    10 2n telekomunikace a.S., www.2n.Cz ® 1.4 terms and symbols the following symbols and pictograms are used in the manual: safety abide by this information to prevent persons from injury. Always warning abide by this information to prevent damage to the device. Always caution important information fo...

  • Page 11

    11 2n telekomunikace a.S., www.2n.Cz ® 2. Description and installation in this section we describe the products and its installation. 2n helios force/safety ® here is what you can find in this section: 2.1 before you start 2.2 mechanical installation 2.3 electric installation 2.4 button tags – inser...

  • Page 12: 2.1 Before You Start

    12 2n telekomunikace a.S., www.2n.Cz ® 2.1 before you start product completeness check please check the contents of your delivery: 2n helios force/safety ® 1× (selected model) 2n helios force/safety ® 1 frame ( only) × 2n helios force ® 1 torx 10 / torx 20 double-ended wrench × bushings (enclosed): ...

  • Page 13: 2.2 Mechanical Installation

    13 2n telekomunikace a.S., www.2n.Cz ® 2.2 mechanical installation mounting type overview refer to the table below for a list of mounting types and necessary components. Wall mounting (concrete and steel structures, entry barrier columns, etc.) what you need: just your unit (the 2n helios force/safe...

  • Page 14

    14 2n telekomunikace a.S., www.2n.Cz ® flush mounting – thermally insulated wall what you need: longer screws (depending on the thermal insulation thickness) for : 2n helios safety ® mounting frame, part no. 9152000 flush mounting – hollow bricks what you need: brick flush mounting box, part no. 915...

  • Page 15: Common Mounting Principles

    15 2n telekomunikace a.S., www.2n.Cz ® common mounting principles wall mounting wall (surface) mounting is used where flush mounting is inapplicable (in concrete and steel structures, entry barrier columns, etc.). The frame is not used. Caution the warranty does not apply to the product defects and ...

  • Page 16

    16 2n telekomunikace a.S., www.2n.Cz ® 1. 2. 3. 4. 5. 6. Select the position 2n helios force/safety ® with respect to the supply cables. Where the cables are installed inside a structure or wall, use the hole at the intercom bottom. Drill holes of the depth of 70 mm for dowels in the wall as shown i...

  • Page 17

    17 2n telekomunikace a.S., www.2n.Cz ® flush mounting – classic bricks 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. If you use the brick flush mounting box, follow the instructions included in the box. If you do not use the mounting box, follow the instructions below: make a hole using the template. Suppose that ...

  • Page 18

    18 2n telekomunikace a.S., www.2n.Cz ® suppose that all the required cables have been carried into the drilled hole. Now follow the instructions applicable for classic brick flush mounting. However, remember that thermally insulated walls show less strength than classic brick walls. Flush mounting –...

  • Page 19: Use of Cable Bushings

    19 2n telekomunikace a.S., www.2n.Cz ® flush mounting – plasterboard use the plasterboard flush mounting box and follow the instructions included therein. Use of cable bushings the cable bushings included in the delivery are designed 2n helios force/safety ® for the following cables: big bushing: fo...

  • Page 20

    20 2n telekomunikace a.S., www.2n.Cz ® 1. 2. 3. 4. 5. 6. 7. How to pull a rj-45 terminated cable through a bushing unscrew the big bushing nut completely. Remove the sealing including the cover from the bushing. Cut either of the components as shown in the figures. Put the bushing nut on the cable a...

  • Page 21: 2.3 Electric Installation

    21 2n telekomunikace a.S., www.2n.Cz ® 2.3 electric installation this subsection describes how to connect to your pbx and 2n helios force/safety ® how to connect supply voltage and the electric lock. Pcb connectors figure below shows the lay-out of connectors on the printe 2n helios force/safety ® d...

  • Page 22: Compatibility

    22 2n telekomunikace a.S., www.2n.Cz ® 1. 2. 3. Number description 1 loudspeaker connector 2 to pushbuttons 3 microphone sensitivity attenuator: high (normal) low 4 microphone connector 5 line connection: rj-12 or screw terminals 6 dc power 12 v for power amplifier and for backlight 7 protecting gro...

  • Page 23

    23 2n telekomunikace a.S., www.2n.Cz ® 2n helios force/safety ® contains a solid-state switch, which is able to switch both ac and dc regardless of polarity. Make sure that the current and voltage values do not exceed limits (refer to the technical data) and that the technical parameters of the lock...

  • Page 24: Mounting Completion

    24 2n telekomunikace a.S., www.2n.Cz ® 1. 2. Mounting completion having connected all the wires, make sure that the bushings, if used, are tightened properly and the rj-45 connector is inserted in the pcb connector (if used). Replace the front cover carefully. Make sure that the wires inside the dev...

  • Page 25: Tag Printing

    25 2n telekomunikace a.S., www.2n.Cz ® 2.4 button tags – insertion and replacement tag printing every name plate includes a piece of foil, which can be written over manually, using a waterproof permanent marker. Tag inserting/replacing 1. 2. 3. 4. 2n helios uni ® provides an intuitive, easy access t...

  • Page 26: 3. Programming and Use

    26 2n telekomunikace a.S., www.2n.Cz ® 3. Programming and use in this section we describe the basic and extending functions of the 2n helios ® product. Force/safety here is what you can find in this section: 3.1 programming 3.2 full parameter chart.

  • Page 27: 3.1 Programming

    27 2n telekomunikace a.S., www.2n.Cz ® 3.1 programming all the intercom parameters, including the keypad ones, are set remotely using any tone-dialling telephone set (or a mobile phone). First call the intercom and enter the programming mode. The access to this mode is service password protected. A ...

  • Page 28: Programming Error

    28 2n telekomunikace a.S., www.2n.Cz ® switch password programming each switch can be controlled with up to 10 different passwords that are listed in the intercom memory. Passwords can be added to the list using function 811 and deleted with function 812 individually. The default status is a single ...

  • Page 29

    29 2n telekomunikace a.S., www.2n.Cz ® deleting all passwords, all memories, complete initialisation the following three functions facilitate your programming by clearing all previous settings: 997 – deletes the entire password list for switch including password 00. 998 – deletes memories of all but...

  • Page 30: 3.2 Full Parameter Chart

    30 2n telekomunikace a.S., www.2n.Cz ® 3.2 full parameter chart all parameters are described in table below. Parameter (function) parameter name range default note 011 to 016 button 01 memories up to16 digits blank note 1: button number 05–54 can be used to store pre-programmed numbers, accessable v...

  • Page 31

    31 2n telekomunikace a.S., www.2n.Cz ® 811 enter up to 10 switch passwords up to 16 digits 00 password 00 cannot be entered from the keypad! Up to 10 switch passwords delete passwords using function 812 812 delete valid switch passwords valid password deletes individual valid switch passwords. 813 s...

  • Page 32

    32 2n telekomunikace a.S., www.2n.Cz ® 934 transmission volume 0–15 7 15 = maximum transmission volume 935 message volume 0–15 7 15 = maximum message volume 936 beeping volume 0–12 12 12 = maximum tone volume 937 dtmf hearing (side tone) volume 0–3 3 3 = maximum dtmf volume 938 loudspeaker volume 0–...

  • Page 33

    33 2n telekomunikace a.S., www.2n.Cz ® 954 count of ringing periods 1–99 10 if the preset count of periods is exceeded, the call is terminated. If the preset count of periods is exceeded and automatic dialling is enabled, another attempt follows. In the event of automatic dialling wit , the ringing ...

  • Page 34

    34 2n telekomunikace a.S., www.2n.Cz ® 976 language selection for a message 0–8 1 0 = 1 = english 2–3 = 4 = german 5–7 = 8 = portuguese 9 = dutch10 ... 99 = silence note: see in survey of messages subs. 4.2 caution! Czech version has language order: 1 = czech, 2 = english 977 language selection for ...

  • Page 35

    35 2n telekomunikace a.S., www.2n.Cz ® explanation of some parameters explanation of parameters 951, 952, 953 ringing tone (example) explanation of parameters 942, 943, 944 busy tone example: the busy tone in the figure above is considerably longer than the pause time. Therefore, set parameter accor...

  • Page 36: 4. Function and Use

    36 2n telekomunikace a.S., www.2n.Cz ® 4. Function and use this section describes the basic and extending functions of the product. Here is what you can find in the section: 4.1 function description 4.2 section for advanced users 4.3 maintenance.

  • Page 37: 4.1 Function Description

    37 2n telekomunikace a.S., www.2n.Cz ® 4.1 function description from external user's view (visitor) like normal doorbells, intercom buttons are provided with labels. The visitor finds the appropriate button (e.G. Mr. Smith) and presses it. This activates the intercom, which then dials the number pre...

  • Page 38

    38 2n telekomunikace a.S., www.2n.Cz ® from internal user's view (survey of functions) calling to 2n helios force/safety ® you call the appropriate extension and the intercom makes the call and gives a confirmation tone after two rings (or as pre-programmed). Now you can speak and control the switch...

  • Page 39

    39 2n telekomunikace a.S., www.2n.Cz ® call extension the intercom beeps 10 seconds before the call end. To extend the call by 30 seconds press on your telephone (dtmf). You can use this function repeatedly. The visitor, however, cannot use this function! Programming the access to this mode is passw...

  • Page 40: Signals Overview

    40 2n telekomunikace a.S., www.2n.Cz ® 1. 2. 3. 4. 5. 6. 7. Signals overview signal name meaning confirmation sent immediately after line seizure for incoming calls (can be heard by the calling party); signals switch activation (by dtmf) – can be heard by the person "at the other end" who activated ...

  • Page 41: Code Lock

    41 2n telekomunikace a.S., www.2n.Cz ® code lock the electronic lock connected to intercom can not only be activated by the phone but also directly from the door using the keypad. In this mode, the keypad behaves like a standard code lock with the following features: both switches can be controlled ...

  • Page 42: Buttons Substitution

    42 2n telekomunikace a.S., www.2n.Cz ® buttons substitution this function is an analogy to memories in comfortable telephone sets. After two digits ranging between 01 and 54 (0 may not be omitted) are pressed, the call to the pre-programmed number is made. You can use intercom as if it had up to 54 ...

  • Page 43

    43 2n telekomunikace a.S., www.2n.Cz ® frequently asked questions about keypad function can any of the switches be activated permanently? Yes, the additional switch can be activated by one password and deactivated by another. Is it possible to arrange for the switch to be activated during the whole ...

  • Page 44

    44 2n telekomunikace a.S., www.2n.Cz ® intercom statuses and available operations operation hang-up outgoing call incoming call programming telephone mode button pressing – new call × — — call extension – dtmf — — call termination – dtmf — hang-up upon continuous, busy or ringing tone — switch activ...

  • Page 45

    45 2n telekomunikace a.S., www.2n.Cz ® pressing (but not vice versa!)..

  • Page 46

    46 2n telekomunikace a.S., www.2n.Cz ® 4.2 section for advanced users automatic multiple number dialling when you press an intercom button, you may find out that the called line is busy or the called party is absent. The intercom is able to identify these situations and solve them by automatic multi...

  • Page 47

    47 2n telekomunikace a.S., www.2n.Cz ® if the ringing tone stops before the predefined count of rings is achieved and the call is thus very short (e.G. 2 seconds), it is not clear whether the call should be regarded as successful. Therefore, a new type of automatic dialling has been added – type 4. ...

  • Page 48

    48 2n telekomunikace a.S., www.2n.Cz ® silent automatic multiple number dialling this mode fully conceals the fact that a telephone call is made. When a button is pressed, the loudspeaker is off and no pbx or dialling tone can be heard. The loudspeaker is switched on when the called subscriber confi...

  • Page 49: Survey of Messages

    49 2n telekomunikace a.S., www.2n.Cz ® survey of messages the table below includes a survey of language versions for standard announcements. English is selected by default. To select another language, use parameters 976 and 977. Value of parameter 976 language selection – english version end of call...

  • Page 50

    50 2n telekomunikace a.S., www.2n.Cz ® 1. 2. 3. 1. 2. How does switching work? Every button has memories for 6 numbers (intended primarily for automatic multiple number dialling). If the automatic multiple number dialling mode is , memory is used for the off 1 day mode and memory for the night mode....

  • Page 51: 4.3 Maintenance

    51 2n telekomunikace a.S., www.2n.Cz ® 4.3 maintenance cleaning if used frequently, the intercom gets dirty. To clean it, use a piece of soft cloth moistened with clean water. We recommend you to obey the following principles while cleaning: never use aggressive detergents (such as abrasives or stro...

  • Page 52

    52 2n telekomunikace a.S., www.2n.Cz ®.

  • Page 53: 5. Technical Parameters

    53 2n telekomunikace a.S., www.2n.Cz ® 5. Technical parameters in this section we describe the technical parameters of the 2n helios force/safety ® product. Telephone parameters.

  • Page 54: Other Electric Parameters

    54 2n telekomunikace a.S., www.2n.Cz ® parameters value conditions minimum required off-hook line current 15 ma off-hook minimum required on-hook line voltage 20 v hang-up dc voltage drop (off-hook) i = 25 ma i = 50 ma lead current while hang-up u = 60 v off-hook ac impedance 220 Ω + 820 Ω 115 nf pa...

  • Page 55: Buttons

    55 2n telekomunikace a.S., www.2n.Cz ® buttons button design: 2n helios force ® : 1 to 4 transparent, white backlit buttons with easily replaceable name tags : 2n helios safety ® one illuminated, stainless steel pushbutton audio microphone: 1 integrated microphone amplifier: optional – additional 0,...

  • Page 56: 6. Supplementary Information

    56 2n telekomunikace a.S., www.2n.Cz ® 6. Supplementary information this section provides supplementary information on the pro 2n helios force/safety ® duct. Here is what you can find in this section: 6.1 troubleshooting 6.2 directives, laws and regulations 6.3 general instructions and cautions.

  • Page 57: 6.1 Troubleshooting

    57 2n telekomunikace a.S., www.2n.Cz ® 6.1 troubleshooting for the most frequently asked questions refer to . Faq.2n.Cz.

  • Page 58: Europe

    58 2n telekomunikace a.S., www.2n.Cz ® 6.2 directives, laws and regulations europe 2n helios force/safety ® conforms to the following directives and regulations: directive 1999/5/ec of the european parliament and of the council, of 9 march 1999 – on radio equipment and telecommunications terminal eq...

  • Page 59

    59 2n telekomunikace a.S., www.2n.Cz ® 6.3 general instructions and cautions please read this user manual carefully before using the product. Follow all instructions and recommendations included herein. Any use of the product that is in contradiction with the instructions provided herein may result ...

  • Page 60

    60 2n telekomunikace a.S., www.2n.Cz ® electric waste and used battery pack handling do not place used electric devices and battery packs into municipal waste containers. An undue disposal thereof might impair the environment! Deliver your expired electric appliances and battery packs removed from t...

  • Page 61

    61 2n telekomunikace a.S., www.2n.Cz ® 2n telekomunikace a.S. Modřanská 621, 143 01 prague 4, czech republic phone: +420 261 301 500, fax: +420 261 301 599 e-mail: sales@2n.Cz web: www.2n.Cz xxx.