2N Helios IP Uni Installation Manual
Summary of Helios IP Uni
Page 1
2n ® helios ip uni door access intercom brief installation manual version: 1.0.2 www.2n.Cz.
Page 3: 1.1 Before You Start
Before you start 1.1 1.1 before you start product completeness check please check the contents of your 2n ® helios ip uni delivery: 1 2n ® helios ip uni (selected model) 1 torx 10 / torx 20 double-ended wrench 1 2n ® helios ip uni installation manual 1 mounting template 1 cd 1 a5 transparent name pl...
Page 4: Mountiong Type Overview
Mechanical installation 1.2 1.2 mechanical installation mountiong type overview refer to the table below for a list of mounting types and necessary components. Flush mounting – classic bricks (also hollow bricks, thermally insulated walls, etc.) what you need: a properly cut hole plaster, mounting g...
Page 5: Common Mounting Principles
Mechanical installation 1.2 caution the warranty does not apply to the product defects and failures arisen as a result of improper mounting (in contradiction herewith). The manufacturer is neither liable for damage caused by theft within an area that is accessible after the attached electric lock is...
Page 6: Flush Mounting
Mechanical installation 1.2 flush mounting – classic bricks 1. Cut a wall hole using the template enclosed. Make sure that all the required cables are available in the hole. 2. Unpack the plastic mounting box. Break out the cable holes as necessary and make sure that the wall hole is big enough for ...
Page 7: Flush Mounting
Mechanical installation 1.2 flush mounting – plasterboard tip if this is your first plasterboard installation, check the function of the intercom side clamps. Loosen and then re-tighten the clamp screw to see how it turns automatically and starts moving forwards in its slot. Remember to return the c...
Page 8: 1.3 Electric Installation
Electric installation 1.3 1.3 electric installation this subsection describes how to connect 2n ® helios ip uni into your local area network (lan) and how to connect supply voltage and the electric lock. Pcb connectors description of connectors lan lan connector out1 12v/700 ma switched output relay...
Page 9: Lan Connection
Electric installation 1.3 lan connection 2n ® helios ip uni is connected to the lan via a rj-45 terminated (connector x11) utp/stp cable (of category cat 5e or higher). The system is equipped with the auto- mdix function and so both the straight and crossed cable versions can be used external power ...
Page 10: 1.4 Button Tags
Button tags – insertion and replacement 1.4 1.4 button tags – insertion and replacement tag printing 1. Every name plate includes a piece of foil, which can be written over manually, using a waterproof permanent marker. Note always use waterproof foil (enclosed or other) for the tags. Never use pape...
Page 11: 1.5 2N
2n® helios ip uni configuration 1.5 1.5 2n ® helios ip uni configuration 2n ® helios ip uni use a pc equipped with any web browser to configure: launch your web browser (internet explorer, firefox, etc.). Enter the ip address of your intercom ( http://192.168.1.100/ , e.G.). Log in using the admin u...
Page 12: 1.6 Maintenance
Maintenance 1.6 1.6 maintenance cleaning if used frequently, 2n® helios ip uni gets dirty. To clean it, use a piece of soft cloth moistened with clean water. We recommend you to obey the following principles while cleaning: never use aggressive detergents (such as abrasives or strong disinfectants)....
Page 13: 1.7 Technical Parameters
Technical parameters 1.7 1.7 technical parameters signalling protocol sip (udp) buttons button design transparent, white backlit buttons with easily replaceable name tags button count 1 or 2 audio microphone 1 integrated microphone amplifier 1w (class d) loudspeaker 1w volume control adjustable with...
Page 16
2n telekomunikace a.S. Modřanská 621, 143 01 prague 4, czech republic tel.: +420 261 301 500, fax: +420 261 301 599 e-mail: sales@2n.Cz web: www.2n.Cz 1815.