2N Helios Uni Installation Manual

Other manuals for Helios Uni: Installation Manual
Manual is about: Door Access Intercom

Summary of Helios Uni

  • Page 1

    2n helios uni door access intercom installation manual version: 1.1 cie-group ltd, www.Cie-group.Com.

  • Page 2

    The 2n telekomunikace a.S. Is a czech manufacturer and supplier of telecommunications equipment. The product family developed by 2n telekomunikace a.S. Includes gsm gateways, private branch exchanges (pbx), and door and lift communicators. 2n telekomunikace a.S. Has been ranked among the czech top c...

  • Page 3

    Content: 1. Product overview 1.1 components and associated products 1.2 terms and symbols 2. Description and installation 2.1 before you start 2.2 mechanical installation 2.3 electric installation 2.4 button tags 3. Function and use 3.1 programming 3.2 full parameter chart 3.3 function description 3...

  • Page 4

    1. Product overview in this section, we introduce the product, outline its application options 2n helios uni ® and highlight the advantages following from its use. Here is what you can find in this section: 1.1 components and associated products 1.2 terms and symbols basic features 2n helios uni ® i...

  • Page 5

    Advantages of use additional amplifier for higher volume water resistant (without any additional roof) high-quality "marine grade" stainless steel front panel variable mounting options (brick/plasterboard flush mounting, wall mounting) no special brick/plasterboard flush mounting accessories needed ...

  • Page 6

    1.1 components and associated products basic units part no. 9153201-e 2n helios uni ® 1 button, analogue part no. 9153202-e 2n helios uni ® 2 buttons, analogue 2n helios uni ® is designed for outdoor applications and requires no additional roof. All units can be flush mounted without requiring any a...

  • Page 7

    Mounting accessories part no. 9153003 wall mounting box (al casting) brick flush mounting box (included in the delivery) cie-group ltd, www.Cie-group.Com 07 / 63.

  • Page 8

    Gsm/umts connection accessories part no. 501303e gsm gateway 2n ® easygate part no. 511333e gsm gateway with battery backup easygate pro 2n ® cie-group ltd, www.Cie-group.Com 08 / 63.

  • Page 9

    Electric locks part no. 932070 befo 1211 12 v / 600 ma part no. 932080 befo 1221 with momentary pin part no. 932090 befo 1211mb with mechanical blocking cie-group ltd, www.Cie-group.Com 09 / 63.

  • Page 10

    Other accessories part no. 91341481e 12 v / 2 a adapter 100–240 v / 12 v / 2 a part no. 932928e 12 v transformer 230 v / 12 v part no. 9134148e siemens adapter ® this is required when connecting to a siemens hipath telephone system cie-group ltd, www.Cie-group.Com 10 / 63.

  • Page 11

    1.2 terms and symbols the following symbols and pictograms are used in the manual: safety always abide by this information to prevent persons from injury. Warning always abide by this information to prevent damage to the device. Caution important information for system functionality. Tip useful info...

  • Page 12

    2. Description and installation in this section we describe the product and its installation. 2n helios uni ® here is what you can find in this section: 2.1 before you start 2.2 mechanical installation 2.3 electric installation 2.4 button tags cie-group ltd, www.Cie-group.Com 12 / 63.

  • Page 13

    Product completeness check please check the contents of your delivery: 2n helios uni ® 1× (selected model) 2n ® helios uni 1× torx 10 / torx 20 double-ended wrench 1× installation manual 2n ® helios uni 1× mounting template 1× cd 1× a5 transparent name plate foil 1× spare name plate 1× brick flush m...

  • Page 14

    2.2 mechanical installation content common mounting principles flush mounting - classic bricks flush mounting - plasterboard wall mounting common mounting principles tip select flush mounting where possible to make your product elegant looking, more vandal resistant and more secure. Caution stainles...

  • Page 15

    1. 2. 3. 4. 5. Caution the warranty does not apply to the product defects and failures arisen as a result of improper mounting (in contradiction herewith). The manufacturer is neither liable for damage caused by theft within an area that is accessible after the attached electric lock is switched. Th...

  • Page 16

    6. 7. 8. 9. 10. 11. You can use the cable tie for connection as shown: mounting completion – after electric installation! Insert the intercom in the mounting box in the wall. Tighten the intercom with the stainless steel screws included in the delivery. As the screw holes are oval, you can perfect t...

  • Page 17

    1. Hole dimensions for flush mounting flush mounting – plasterboard what you need: just a properly cut hole tip if this is your first plasterboard installation, check the function of the intercom side clamps. Loosen and then re-tighten the clamp screw to see how it turns automatically and starts mov...

  • Page 18

    1. 2. 3. 4. 5. 6. 7. Cut a hole 100 (w) × 180 (h) mm. Unscrew the front panel from the door intercom. Connect the cables in the hole to the terminals or rj connector as described in the . Electric connection subsection mounting completion – after electric installation! Insert the intercom in the hol...

  • Page 19

    1. 2. 3. 4. 5. 6. 7. Wall mounting use the wall (surface) mounting box, part no. , and follow the instructions 9153003 enclosed. (concrete and steel structures, entry barrier columns, etc.) what you need: wall mounting box part no. 9153003 mounting instructions: a) if the cable wall outlets are loca...

  • Page 20

    Dimension for wall (surface) mounting cie-group ltd, www.Cie-group.Com 20 / 63.

  • Page 21

    2.3 electric installation this subsection describes how to connect into your local area 2n helios uni ® network (lan) and how to connect supply voltage and the electric lock. Pcb connectors description of connectors: line – an analogue telephone line with any polarity, or an rj connector or terminal...

  • Page 22

    1. 2. 3. Compatibility 2n helios uni ® is designed for conventional, analogue telephone lines and works regardless of polarity and line parameters.(refer to the technical parameters) and uses tone (dtmf) or pulse dialling to be programmed. Normally, it is connected to a pbx line however it can also ...

  • Page 23

    Caution if the lock power supply fails and the telephone system carries on working, the intercom is unaware of the failure the switch will be password-activated and the activation is acoustically signalled, but the electric lock will not work because of the lack of power. Ground connection is mandat...

  • Page 24

    1. 2. 1. 2. 3. 4. 2.4 button tags tag printing every delivery includes a sheet of translucent foil, which can be 2n helios uni ® laser-printed. Cut the printed foil and insert the tags in the name plates. Every name plate includes a piece of foil, which can be written over manually, using a waterpro...

  • Page 25

    Cie-group ltd, www.Cie-group.Com 25 / 63.

  • Page 26

    3. Function and use in this section we describe the basic and extending functions of the 2n helios uni ® product. Here is what you can find in this section: 3.1 programming 3.2 full parameter chart 3.3 function description 3.4 section for advanced users 3.5 maintenance 3.6 downloads cie-group ltd, w...

  • Page 27

    3.1 programming ll the intercom parameters, including the keypad ones, are set remotely using any tone- dialling telephone set (or a mobile phone). First call the intercom and enter the programming mode. The access to this mode is service password protected. A voice menu is available in the programm...

  • Page 28

    Contents (excluding passwords). Now you can enter new data – of variable meaning and length depending on the parameter selected (refer to the full parameter chart). Finally, press again for confirmation. The intercom confirms the data saving. Repeat this procedure for each parameter. Switch password...

  • Page 29

    If you do not press any button within a predefined timeout, the intercom sends a hang-up signal and hangs up. The timeout is 5 seconds; every character is followed by 30 seconds for you to think over your setting. The 5-second limit starts when the intercom has read all that relates to the current u...

  • Page 30

    If you forget the service password if you forget the service password, contact the manufacturer. The manufacturer can change your service password to 12345 remotely without altering any other parameter. Tip keyboard letters facilitate password remembering. For example, it is easier to remember a 9-l...

  • Page 31

    3.2 full parameter chart parameter (function) parameter name range default note 011 to 016 button 01 memories up to16 digits blank 021 to 026 button 02 memories up to16 digits blank digits 0–9 can only be entered directly into the memories. Special characters are entered additionally using function ...

  • Page 32

    Parameter (function) parameter name range default note 811 enter up to 10 switch passwords up to 16 digits 00 password 00 cannot be entered from the keypad! Up to 10 switch passwords delete passwords using function 812 812 delete valid switch passwords valid pass- word deletes individual valid switc...

  • Page 33

    Parameter (function) parameter name range default note 912 max. Call duration 1–99 12 = 120 s range of 10 s – 990 s 913 log-in timeout 1–99 3 3 = 30 seconds 915 hang-up time between calls 5–99 15 = 1,5 s 931 microphone power-up level 0–3 2 0 = maximum microphone sensitivity 932 automatic response sp...

  • Page 34

    Parameter (function) parameter name range default note 941 minimum continuous tone time 10– 99 20 = 2s if the tone is longer, the intercom hangs up. 942 minimum busy tone or pause duration 0– 255 8 = 0.08 s these parameters control the busy tone detection. They are used for call termination and auto...

  • Page 35

    Parameter (function) parameter name range default note 951 minimum ringing tone time 1– 200 50 = 0,5 s 2) the longest ringing period pause must be in the interval between parameters 952 and 953. Warning! As these parameters also detect incoming calls, an incorrect setting may result in the intercom ...

  • Page 36

    Parameter (function) parameter name range default note 964 possibility to dial the next number by pressing 2nd button 0 = no 1 = yes 1 971 count of message repetitions 0–9 3 there is a 3-second pause between every two messages. 974 intercom identification number 16 digits - the number enables interc...

  • Page 37

    Parameter (function) parameter name range default note 976 language selection for a message 0–8 1 0 = 1 = english 2–3 = 4 = german 5–7 = 8 = portuguese 9 = dutch10 ... 99 = silence note: see in subs. 4.2 survey of messages caution! Czech version has language order: 1 = czech, 2 = english 977 languag...

  • Page 38

    Notes terminology: for the purpose hereof, means a that is parameter value stored in the intercom memory and can be re-programmed. Is function a means of execution of another service such as initialisation, software version identification and so on. 1) types 3 and 4 of automatic dialling without con...

  • Page 39

    Example: the busy tone in the figure above is considerably longer than the pause time. Therefore, set parameter according to the pause, to 200 ms, e.G., and parameter 942 according to the tone, to 600 ms, for example. In this case, however, the default 943 values can be maintained for both the param...

  • Page 40

    3.3 function description from external user's view (visitor) like normal doorbells, intercom buttons are provided with labels. The visitor finds the appropriate button (e.G. Mr. Smith) and presses it. This activates the intercom, which then dials the number pre-programmed for that button, the visito...

  • Page 41

    From internal user's view (survey of functions) calling to 2n ® helios uni you call the appropriate extension and the intercom makes the call and gives a confirmation tone after two rings (or as pre-programmed). Now you can speak and control the switch, program the intercom (see later), and listen t...

  • Page 42

    Programming the access to this mode is password-protected. For details refer to the programming section. The voice menu helps you considerably with programming the intercom. Having entered the programming mode, you can also alter any parameter and memory settings. Caution the above mentioned functio...

  • Page 43

    1. 2. 3. 4. 5. 6. Signal name meaning "attention, your call is being terminated" signals that the preset maximum call time will elapse within 10 seconds. "wait, please" optional message during call establishing. "communicator number ... Is calling" optional message for intercom identification voice ...

  • Page 44

    2n ® helios uni statuses and available operations operation hang- up outgoing call incoming call programming button pressing – new call y × — — call extension – dtmf — y y — call termination – dtmf — y y y hang-up upon continuous, busy or ringing tone — y y y switch activation – dtmf password — × × ...

  • Page 45

    3.4 section for advanced users automatic multiple number dialling when you press an intercom button, you may find out that the called line is busy or the called party is absent. The intercom is able to identify these situations and solve them by automatic multiple number dialling if one of three aut...

  • Page 46

    Situation intercom action ringing tone, which is terminated before 10 rings are made (the count of rings is variable) regarded as a successful call, continues for the maximum timeout (maximum call duration). For details refer to the text under the table. Ringing tone, 10 rings are made (the count of...

  • Page 47

    Evaluation of situations in audible automatic dialling with confirmation situation intercom action busy tone hangs up in approximately 2 seconds and dials the next number. Call or silence waits for the preset timeout (log-in time), then hangs up and dials the next number. Ringing tone waits for the ...

  • Page 48

    Silent automatic multiple number dialling this mode fully conceals the fact that a telephone call is made. When a button is pressed, the loudspeaker is off and no pbx or dialling tone can be heard. The loudspeaker is switched on when the called subscriber confirms connection (by pressing on its tele...

  • Page 49

    Dtmf character function or call . Termination to these digits are interpreted as a password beginning – for switch control. Notes these commands do not work in the automatic multiple number dialling mode without confirmation! The above-mentioned commands due to poor may not be accepted connection if...

  • Page 50

    Survey of messages the table below includes a survey of language versions for standard announcements. English is selected by default. To select another language, use parameters 976 and 977. Value of parameter 976 language selection – english version end of call message outgoing call message id messa...

  • Page 51

    Value of parameter 977 language selection – english version outgoing call message note 0 tone signal off to play this message, parameter 975 must start with digit 5. Parameter 977 has a range 0–99. On customer's request, additional messages can be added; e.G. Other languages or more alternative mess...

  • Page 52

    1. 2. 3. 1. 2. How does switching work? Every button has memories for 6 numbers (intended primarily for automatic multiple number dialling). If the automatic multiple number dialling mode is , memory is used for the off 1 day mode and memory for the night mode. This is a simple two-number 3 switchin...

  • Page 53

    3.5 maintenance cleaning if used frequently, the intercom gets dirty. To clean it, use a piece of soft cloth moistened with clean water. We recommend you to obey the following principles while cleaning: never use aggressive detergents (such as abrasives or strong disinfectants). Alcohol-based cleane...

  • Page 54

    Templates nametags cie-group ltd, www.Cie-group.Com 54 / 63.

  • Page 55

    4. Technical parameters telephone parameters parameters value conditions minimum required off-hook line current 15 ma off-hook minimum required on-hook line voltage 20 v hang-up dc voltage drop (off-hook) i = 25 ma i = 50 ma lead current while hang-up u = 60 v off-hook ac impedance 220 Ω + 820 Ω 115...

  • Page 56

    Parameters value conditions 350 to 500 hz busy tone detection speed variable 350 to 500 hz continuous tone detection speed variable 350 to 500 hz ringing tone detection speed variable 350 to 500 hz overvoltage protection – common mode 1000 v 8 / 20 μs overvoltage protection – between a, b conductors...

  • Page 57

    Physical properties cover: abs plastic, high-quality stainless steel working temperature: −25°c to +55°c working relative humidity: 10% to 95% (non-condensing) storing temperature: −40°c to 70°c dimensions: (193 × 115 × 39) mm (197 × 119 × 47) mm flush box (193 × 115 × 57) mm for wall mounting weigh...

  • Page 58

    5. Supplementary information this section provides supplementary information on the product. 2n helios uni ® here is what you can find in this section: 5.1 troubleshooting 5.2 directives, laws and regulations 5.3 general instructions and cautions cie-group ltd, www.Cie-group.Com 58 / 63.

  • Page 59

    5.1 troubleshooting for the most frequently asked questions refer to . Faq.2n.Cz cie-group ltd, www.Cie-group.Com 59 / 63.

  • Page 60

    Europe 2n helios uni ® conforms to the following directives and regulations: directive 1999/5/ec of the european parliament and of the council, of 9 march 1999 - on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity directive 2006/95/ec of the eu...

  • Page 61

    5.3 general instructions and cautions please read this user manual carefully before using the product. Follow all instructions and recommendations included herein. Any use of the product that is in contradiction with the instructions provided herein may result in malfunction, damage or destruction o...

  • Page 62

    The consumer shall, without delay, change the access password for the product after installation. The manufacturer shall not be held liable or responsible for any damage incurred by the consumer in connection with the use of the original password. The manufacturer also assumes no responsibility for ...

  • Page 63

    Cie-group ltd, www.Cie-group.Com 63 / 63.