Installation and operating instructions for 3mdw201 full flow drinking water system 3m clean water solutions homeowner: please retain for operation and future maintenance instructions..
Safety information explanation of signal word consequences read, understand, and follow all safety information contained in these instructions prior to in- stallation and use of the 3mdw201 full flow drinking water system. Retain these instructions for future reference. Intended use: the 3mdw201 ful...
Parts and materials required for 3mdw201 undersink installation (included): 1. Filter head assembly 2. Filter items required (not included): • adjustablewrench • cordlessdrill • phillipsheadscrewdriver • razorknifeortubecutter • additionalinstallationpartsmay berequired • 3mdwiktinstallationkit gett...
1. Openfaucetandturnoffcoldwatersupplytorelievepressure. 2. Selectandmarkalocationunderthesinkthatallowsac- cessforfilterchange.Youwillbeconnectingtotheexisting linewith3/8”tubingandvariousfittingsnotsuppliedwith thisfilterassembly. 3. Usingfilterheadassemblyasaguide,fastenfilterheadas- semblytowall...
Filter replacement instructions 1. Placetowelunderfiltertocollectanyresidualwaterduringreplacementfilterchange-out. 2. Graspfilterandturntotheleft(counterclockwise)untilfiltercomestoacompletestop(waterautomaticallyturnsoff). Watermayleakmomentarilyfromventtube.Thisisnormal.Gentlypullfilterdownwardto...
Troubleshooting guide water leaks at push-in connections: pushtubinginasfarasitwillgo.Ifleakingcontinues,shutoffwateratthecoldwatersupplyvalveandremove waterlinebypushinginontheconnectorcollarwhilepullingthetubingaway.Inspecttubingforcracksand scratches.Iftubingiscrackedorscratched,simplycutthatport...
3misatrademarkof3mcompany. ©20093mcompany.Allrightsreserved. Instr80290909 manufacturedby3m 400researchparkway meriden,ct06450 1-877-238-9119 www.3mcleanerworld.Com.