    Half facepiece respirator 6000 series user instructions for 3m™ 6100 (small), 07024 (small), 6200 (medium), 07025 (medium), 6300 (large), 07026 (large) half facepieces* important: keep these user instructions for reference. * 07024, 07025, 07026 are catalog numbers only. Niosh approved 3m™ 6100 (sma...

  • Page 2

    General safety information intended use the 3m™ 6000 series half facepiece respirators are niosh approved and designed to help provide respiratory protection against certain airborne contaminants when used in accordance with all use instructions and limitations and applicable safety and health regul...

  • Page 3

    Use instructions & limitations important before use, the wearer must read and understand these user instructions. Keep these user instructions for reference. Use for respiratory protection from certain airborne contaminants according to niosh approvals, osha limitations, in canada csa standard z94.4...

  • Page 4

    1. If respirator becomes damaged, leave contaminated area immediately and repair or replace the respirator. 2. Replace filters in accordance with the filter time use limitation. (see filter user instructions.) 3. Replace cartridges in accordance with an established change schedule or earlier if smel...

  • Page 5

    If the facepiece is to be used in air purifying mode (without using the 3m sa-1600 or sa-2600 breathing tubes), the inhalation valves must be replaced in the facepiece before use. Cartridge and filter selection and approvals before using any of these products, the user must read the specific use for...

  • Page 6

    Number ****aad description 504 07065 respirator cleaning wipes 601 quantitative fit test adapter 6889 exhalation valve 6893 07144 inhalation valve 6895 07145 inhalation gasket 6281 head harness assembly 6880 37002 bayonet cap caution failure to properly dispose of spent cartridges, filters, or respi...

  • Page 7

    Hydrogen sulfide, ammonia/methylamine, formaldehyde or hydrogen fluoride and particulates 1 60928 organic vapor/acid gas/p100 certain organic vapors, chlorine, hydrogen chloride, and sulfur dioxide or hydrogen sulfide or hydrogen fluoride and particulates. 2 60929 mercury vapor/chlorine gas/p100 mer...

  • Page 8

    5n11 particulate filter, n95 5p71 07194 particulate filter, p95 7093 particulate filter, p100 7093c 37173 particulate filter, p100, hydrogen fluoride with nuisance level organic vapor/acid gas relief 1 ****aad part numbers are catalog numbers only. Niosh approved as oh&esd part numbers 1 3m recommen...

  • Page 9

    Note: the 3m tm filter adapter 502, once installed on a 3m™ cartridge 6000 series, is not to be removed or reused. Removal or reuse may result in leakage, overexposure, sickness or death. 3m™ 2000 series and filters 7093/7093c with 3m™ filter adapter 502 place filter onto the filter holder so that f...

  • Page 10

    2. Attach 3m sa-1600 or sa-2600 breathing tubes to facepiece per the procedures outlined previously. The procedure is identical to the 3m sa-1500 and sa-2500 models. 3. Make a selection of cartridges and/or filters that meets your respiratory protection requirements, and attach to outer bayonets of ...

  • Page 11

    If you cannot achieve a proper fit, do not enter contaminated area. See your supervisor. Negative pressure seal check (with 6000 series cartridges) 1. Place palms of hands to cover face of cartridge or open area of 3m™ 501 filter retainer, when retainer is attached to the cartridge, to restrict air ...

  • Page 12

    Quantitative fit testing quantitative fit testing (qnft) can be conducted using a 3mtm 601 fit test adapter and p100 filters such as the 3m™ 2091 or 7093 p100 particulate filters. Qualitative fit testing qualitative fit testing (qlft) with the 3m™ ft-10 or ft-30 qualitative fit test apparatus can be...

  • Page 13

    3. Disinfect facepiece by soaking in a solution of quaternary ammonia disinfectant or sodium hypochlorite (1 oz. [30 ml] household bleach in 2 gallons [7.5 l] of water), or other disinfectant. 4. Rinse in fresh, warm water and air dry in non-contaminated atmosphere. 5. The cleaned respirator should ...

  • Page 14

    For more information in united states, contact: website: www.3m.Com/occsafety technical assistance: 1-800-243-4630 for other 3m products: 1-800-3m-helps or 1-651-737-6501 3m occupational health and environmental safety division 3m center, building 0235-02-w-70 st. Paul, mn 55144-1000 ©3m 2007 98-006...

  • Page 15

    15 fig. 1 fig. 2 fig. 3 fig. 4 fig. 5 fig. 6 fig. 7 fig. 8 fig. 9 fig. 10 fig. 11 fig. 12 fig. 13 fig. 14 fig. 15 fig. 16 fig. 17 fig. 18 fig. 19.