3M 724 User Manual - page 14
14
SECTION 4
Selection of Test Voltage and Resistance Limit
Tools required – Small blade, screwdriver.
The 3M
™
Workstation Monitor 724 allows for the selection of test voltages (9V
or 16V) and resistance limits (10 Megohms or 35 Megohms). The additional
ranges have been added to accommodate global ESD requirements. Selection of
the operating parameters are left up to the user’s discretion.
a) Select the desired resistance and voltage limit by moving the appropriate
slide switch (with screwdriver) on the side of the Workstation Monitor 724
to the desired position (Figure 2).
SECTION 5
Mounting the 3M Workstation Monitor 724 and
3M
™
Dual Conductor Remote Input Jack 732
a) Mount or position the Workstation
Monitor 724 so that the lamps
are easily viewed by the operator
(Figs. 10 and 11). Mount the
Workstation Monitor 724 to the
underside of a work bench top
or shelf through the two holes
located at the top rear of the case
using the two screws supplied. If
using the screws is not possible,
apply an appropriate amount of
durable, double-sided adhesive
foam tape to the case.
b) Locate the Dual Conductor
Remote Input Jack 732 so that
it is convenient for the operators
to attach their wrist strap ground
cord. Mount the remote with the
screws provided.
Figure 10 – 3M
™
Workstation Monitor 724
mounted on bench top.
Figure 11 – 3M
™
Workstation Monitor 724
mounted under shelf or bench.