3M Touch Systems Proprietary Information
20
3M Dynapro ET 3170 Terminal User’s Installation Guide
Steps
To mount the terminal in a panel or wall cutout:
1.
Use the full-scale cutout template that came with your unit to mark the
dimensions and screw holes on the panel or wall (for cutout dimensions, see
Appendix A).
2.
Make the cutout and drill the holes.
If you are mounting the terminal in an enclosed cabinet, make sure that there
is a minimum of 1 inch (25.4 mm) clearance behind the unit for proper air
circulation. In warm working environments, the depth of the enclosure
should be increased to provide better air circulation.
3.
Bring the power cable and the communication cables up to the cutout.
Figure 8: Side view: Panel cutout mount (without seal)
4.
If applicable, insert optional security screws (security screws and
screwdriver are available from 3M Touch Systems).
5.
Attach communication cables. For instructions, see “Typical installation”
beginning on page 9.
6.
After making sure that the power at the source is off, connect power to the
terminal.
7.
Place the terminal in the cutout. You may need assistance to hold it in place.
8.
Attach the terminal to the panel from the back. Two lengths of screws
(½-inch and ¾-inch) are provided with the terminal. Use the screw length
appropriate for the thickness of your panel. Tighten the screws to a torque of
12 inch-pounds.
If neither of the screw sizes supplied is adequate, use size #10-32 screws,
that are long enough to extend through the panel surface but will not intrude
more than ¼-inch into the holes in the bezel.
9.
Connect power to the terminal at the source.
Summary of Dynapro ET 3170 Terminal Series B
Page 1
Et 3170 terminal (series b) user’s installation guide read and understand all safety information before installing and using this product. 3m touch systems proprietary information.
Page 2
Copyright this manual is © 3m 2002. All rights reserved. Reproduction of the contents of this copyrighted manual in whole or in part, by any means, electronic or mechanical, for any purpose, without written permission of 3m touch systems, a subsidiary of 3m, is prohibited. Notice given the variety o...
Page 3: Important Safety Information
3m touch systems proprietary information i important safety information read and understand all safety information before using the 3m dynapro tm et 3170 terminal. Follow all instructions marked on the product and described in this document. Pay close attention to the statement of intended use and t...
Page 4
3m touch systems proprietary information ii 3m dynapro et 3170 terminal user’s installation guide warning to reduce the risks associated with electrical shock or fire which, if not avoided, could result in death or serious injury and/or property damage: ! Provide a clean, reliable grounding. ! When ...
Page 5
3m touch systems proprietary information iii important safety information safety labels the following safety symbols appear on your 3m dynapro industrial product and its packaging materials: symbol meaning consult user instructions. Caution: risk of electric shock. Caution: item is susceptible to el...
Page 7: Information Importante
Données brevetées 3m touch systems v information importante sur la sécurité lire les renseignements de sécurité et les comprendre avant d’utiliser le terminal dynapro et 3170 de 3m. Suivre toutes les instructions indiquées sur le produit et décrites dans le présent manuel. Prêter une attention spéci...
Page 8
Données brevetées 3m touch systems vi guide d’installation et d’utilisation du terminal dynapro et 3170 de 3m avertissement pour réduire les risques d’incendie et d’électrocution susceptibles, faute de précau- tion, de causer la mort, des blessures graves ou des dommages matériels : fournir une mise...
Page 9
Données brevetées 3m touch systems vii information importante sur la sécurité Étiquettes de sécurité les symboles de sécurité suivants apparaissent sur le produit industriel dynapro de 3m et sur son emballage : symbole signification des symboles consulter le mode d’emploi. Avertissement : risque d’é...
Page 11: Belangrijke
Informatie aangaande eigendomsrechten 3m touch systems i x belangrijke veiligheidsinformatie voordat de 3m dynapro™ et 3170 terminal wordt gebruikt, moet alle veilig- heidsinformatie zijn gelezen en begrepen. Volg alle op het product aangegeven en in dit document beschreven instructies op. Besteed e...
Page 12
Informatie aangaande eigendomsrechten 3m touch systems x installatiehandleiding 3m dynapro et 3170 terminal voor de gebruiker waarschuwing neem het volgende in acht om de risico’s van elektrische schokken of brand te redu- ceren die, indien deze niet worden voorkomen, ernstig letsel, de dood en/of s...
Page 13
Informatie aangaande eigendomsrechten 3m touch systems xi belangrijke veiligheidsinformatie veiligheidslabels de volgende veiligheidssymbolen staan op het industriële 3m dynapro product en de verpakkingsmaterialen: voorzichtig neem het volgende in acht om de risico’s van brand te reduceren die, indi...
Page 15: Wichtige Sicherheitshinweise
3m touch systems firmeneigene informationen xiii wichtige sicherheitshinweise bevor sie das 3m dynapro™ et 3170 terminal benutzen, müssen sie alle si- cherheitshinweise gelesen und verstanden haben. Befolgen sie alle am produkt angebrachten und in diesem dokument beschriebenen anweisungen. Achten si...
Page 16
3m touch systems firmeneigene informationen xiv bedienungsanleitung für 3m dynapro et 3170 warnhinweise um elektroschock- und brandgefahr mit möglichen schweren verletzungs- oder to- desfolgen und/oder sachschäden zu vermeiden: bei der installation des et-geräts die betriebsumgebung (z.B. Thermische...
Page 17
3m touch systems firmeneigene informationen xv wichtige sicherheitshinweise sicherheitssymbole die folgenden sicherheitssymbole sind auf ihrem 3m dynapro und dessen ver- packung abgebildet: vorsicht um brandgefahr mit möglichen sachschäden zu vermeiden: nur das im lieferumfang enthaltene installatio...
Page 19: Sicurezza
Informazioni sui sistemi 3m touch soggette a diritti di proprietà xvii importanti informazioni sulla sicurezza si prega di leggere ed assimilare bene tutte le norme di sicurezza prima di utiliz- zare il terminale dynapro™ et 3170 di 3m. Seguire tutte le istruzioni indicate sul prodotto e descritte n...
Page 20
Informazioni sui sistemi 3m touch soggette a diritti di proprietà xviii guida all’installazione del terminale et 3170 dynapro di 3m per l’utente avvertenza per ridurre i rischi associati ad incendio ed esplosione che, se non evitati, possono causare la morte o il ferimento grave di persone e/o il da...
Page 21
Informazioni sui sistemi 3m touch soggette a diritti di proprietà i x importanti informazioni sulla sicurezza etichette di sicurezza sul vostro prodotto industriale dynapro 3m e sul relativo materiale da imballag- gio saranno esposti i seguenti simboli: attenzione per ridurre i rischi associati ad i...
Page 23: Información Importante De
Información patentada de 3m touch systems xxi información importante de seguridad lea y comprenda la información completa de seguridad antes de utilizar la termi- nal 3m dynapro™ et 3170. Siga las instrucciones marcadas en el producto y que se describen en este documento. Preste mucha atención a la ...
Page 24
Información patentada de 3m touch systems xxii guía del usuario para la instalación de la terminal 3m dynapro et 3170 advertencia para reducir los riesgos asociados con choque eléctrico o incendios, los cuales, si no se evitan, pueden ocasionar la muerte o serias lesiones o daños a la propiedad: pro...
Page 25
Información patentada de 3m touch systems xxiii información importante de seguridad etiquetas de seguridad los siguientes símbolos de seguridad aparecen en el producto industrial y en los materiales de empaque de 3m dynapro: precauciÓn para reducir los riesgos asociados con contaminación ambiental, ...
Page 27
3m touch systems ϧֵ᳝ᙃ xxv 䞡㽕ᅝֵܼᙃ 䞡㽕ᅝֵܼᙃ 䞡㽕ᅝֵܼᙃ 䞡㽕ᅝֵܼᙃ Փ⫼ 3m dynapro tm et 3170 terminal Пࠡ 䇋䯙䇏ᑊ⧚㾷᠔᳝ᅝֵܼ ᙃ 䇋ᣝ✻ѻકϞᴀ᭛Ёᷛ䆄ⱘՓ⫼䇈ᯢ䖯㸠᪡ ᑨ⡍߿⊼ᛣ⫼䗨 ᅝܼџ乍ⱘໄᯢ ⫼䗨 ⫼䗨 ⫼䗨 ⫼䗨 䖲ࠄЏᴎৢ 3m dynapro tm et 3170 terminal ৃҹЎ⾡ᎹϮᑨ⫼ᦤկ 㾺ᩌሣࡳ㛑 et 3170 terminal ϡ㛑ॅ䰽എড়ЁՓ⫼ བ䍙䖛㾘ᅮⱘ ᴵӊϟՓ⫼ᴀ㒜ッ ֱׂᇚ༅ᬜ Ϩ⫼᠋乏㞾㸠ᡓᢙ亢䰽䋷ӏ et 3170 terminal ᰃϔϾ㒘ӊ...
Page 28
3m touch systems ϧֵ᳝ᙃ xxvi 3m dynapro et 3170terminal ⫼᠋ᅝ㺙ᣛफ 䄺ਞ 䄺ਞ 䄺ਞ 䄺ਞ ሑৃ㛑䙓ܡ㾺⬉☿♒㗠ᓩ䍋Ҏ䑿Ӹѵ 䋶ѻᤳ༅ ሑৃ㛑䙓ܡ㾺⬉☿♒㗠ᓩ䍋Ҏ䑿Ӹѵ 䋶ѻᤳ༅ ሑৃ㛑䙓ܡ㾺⬉☿♒㗠ᓩ䍋Ҏ䑿Ӹѵ 䋶ѻᤳ༅ ሑৃ㛑䙓ܡ㾺⬉☿♒㗠ᓩ䍋Ҏ䑿Ӹѵ 䋶ѻᤳ༅ ᑨᦤկᅠܼ ৃ䴴ⱘഄ ᔧᅝ㺙 et 䆒ᯊ ⊼ᛣϡ㽕䍙ߎ⬉⑤⬉䏃䖛⬉⌕ֱᡸ䜡㒓㾘㣗 䇋Փ⫼᮴⸈ᤳ ᳝ᬜⱘ nema 4x/ip66 ൿᴹℷ⹂ᅝ㺙 et 䆒 བᵰ䳔㽕Փ⫼ nema 4x/ip66㒱㓬ሖ Ԛet䆒ϡヺড়nema 4x/ip...
Page 29
3m touch systems ϧֵ᳝ᙃ xxvii 䞡㽕ᅝֵܼᙃ ᅝܼᷛᖫ ᅝܼᷛᖫ ᅝܼᷛᖫ ᅝܼᷛᖫ ϟ߫ᅝܼヺোߎ⦄ᙼⱘ 3m dynapro ᎹϮѻકঞ݊ࣙ㺙ᴤ᭭Ϟ ヺো ヺো ヺো ヺো ᛣН ᛣН ᛣН ᛣН 䇋খ䯙⫼᠋䇈ᯢк ᇣᖗ ᳝㾺⬉ॅ䰽 ᇣᖗ བᵰϡџܜ䞛প䗖ᔧⱘ乘䰆ᮑ ৃ㛑Ӯߎ⦄䴭⬉䞞ᬒ (6' ⦄䈵 ᦤछॅ䰽.
Page 31: Contents
3m touch systems proprietary information xxix contents before you start about the user’s installation guide.......................................... 1 about this guide.................................................................................................... 1 related documents...............
Page 33: List of Tables
3m touch systems proprietary information xxxi list of tables table a: com a rs-232 connector pin-out .................................................... 12 table b: com a rs-422 connector pin-out (full duplex) ............................... 13 table c: com a rs-485 connector pin-out (half duplex) ...
Page 35: List of Figures
3m touch systems proprietary information xxxiii list of figures figure 1: enclosure dimensions .......................................................................... 7 figure 2: terminal connectors........................................................................... 11 figure 3: connecting...
Page 37: Guide
3m touch systems proprietary information 1 before you start about the user’s installation guide about this guide who should read this guide the 3m dynapro tm et 3170 terminal user’s installation guide is a resource for the installation and use of the 3m dynapro et 3170 terminal (series b). This guid...
Page 38
3m touch systems proprietary information 2 3m dynapro et 3170 terminal user’s installation guide what is included here is a summary of topics covered in the manual: related documents there are other documents that provide additional information on the terminal. Service guide for qualified service pe...
Page 39
3m touch systems proprietary information 3 about the user’s installation guide 3m touch systems support services 3m touch systems provides extensive support services through our web site and technical support organization. Visit www.3mtouch.Com, to download touch screen software and drivers, obtain ...
Page 40
3m touch systems proprietary information 4 3m dynapro et 3170 terminal user’s installation guide 3m touch systems worldwide offices all offices can be reached through the web site: www.3mtouch.Com. Country telephone united kingdom 978-659-9000 united states 978-659-9000 australia +61 395-82-4799 can...
Page 41
3m touch systems proprietary information 5 chapter 1 introducing the et 3170 terminal about this chapter this chapter provides an overview of the 3m dynapro tm et 3170 terminal (series b), including: ! Features of the terminal. ! Options available for configuring (customizing) the terminal for your ...
Page 42
3m touch systems proprietary information 6 3m dynapro et 3170 terminal user’s installation guide communications the following communication connectors are at the rear of the terminal. ! Rs-232/rs-422/rs-485 serial port ! Standard 101-key interface with an industry-standard at-type keyboard connector...
Page 43: Unpacking The Terminal
3m touch systems proprietary information 7 chapter 2 unpacking the terminal unpacking the terminal the following items ship with all terminals. If you ordered options, check the contents label on the box to be sure they are included. ! Et 3170 terminal figure 1: enclosure dimensions ! Et 3170 user’s...
Page 45: Installing The Terminal
3m touch systems proprietary information 9 chapter 3 installing the terminal about this chapter this chapter outlines: ! How to do a typical installation of the et 3170 terminal ! How to connect a serial device ! How to connect a keyboard ! How to connect ac power typical installation this section e...
Page 46
3m touch systems proprietary information 10 3m dynapro et 3170 terminal user’s installation guide summary of installation steps 1. Decide where you want to install the terminal. For guidelines on locating the terminal, see “guidelines” on page 17. 2. Determine what communication devices you will be ...
Page 47
3m touch systems proprietary information 11 installing the terminal 5. Connect power to the power source. 6. Mount the terminal in its final location (for details on mounting, see chapter 4). Connectors communication and power connections are at the back of the terminal. You can use standard cables ...
Page 48
3m touch systems proprietary information 12 3m dynapro et 3170 terminal user’s installation guide connecting a serial device the terminal has one asynchronous serial port that can be used to connect to your host system. This port is 16550 uart-based and can transmit data at speeds up to 19,200 baud....
Page 49
3m touch systems proprietary information 13 installing the terminal rs-422 communication for rs-422 communications, make a cable using the pin-out in table b. For maximum cable length, refer to the eia rs-422 specification standard. Rs-485 communication for rs-485 communication, make a cable using t...
Page 50
3m touch systems proprietary information 14 3m dynapro et 3170 terminal user’s installation guide the keyboard port can also be used to connect a bar code reader or magnetic stripe card reader. Connecting ac power use an ac power cable that is appropriate for the power scheme in your country or regi...
Page 51
3m touch systems proprietary information 15 installing the terminal figure 3: connecting power: ac power cable with iec connector 3. Connect the other end of the power cable to a standard 15-ampere (or less) branch circuit. Connecting ac power: fixed field wiring to connect the power supply with fix...
Page 52
3m touch systems proprietary information 16 3m dynapro et 3170 terminal user’s installation guide 5. Using a 1/8-inch flathead screwdriver, turn the terminal block’s screw clockwise until the neutral cable wire is firmly attached to the terminal. Figure 4: connecting ac power cable wires to connecto...
Page 53: Mounting
3m touch systems proprietary information 17 chapter 4 mounting about this chapter this chapter provides: ! Overview of methods for mounting the et 3170 terminal. For detailed information on mounting methods, consult the mounting installation instructions that came with your mounting kit (and which a...
Page 54
3m touch systems proprietary information 18 3m dynapro et 3170 terminal user’s installation guide ergonomics to help prevent undo physical stress on users of the terminal, follow these guidelines. Position the terminal so that: ! It is at a level that is suitable for most users. If the unit is place...
Page 55
3m touch systems proprietary information 19 mounting standard mounting methods there are two standard panel mounting methods possible for the terminal: ! Panel cutout mount. Using this method, you can attach the terminal to a wall or panel with rear-mounted screws. ! Panel gasket mount. Using the ne...
Page 56
3m touch systems proprietary information 20 3m dynapro et 3170 terminal user’s installation guide steps to mount the terminal in a panel or wall cutout: 1. Use the full-scale cutout template that came with your unit to mark the dimensions and screw holes on the panel or wall (for cutout dimensions, ...
Page 57
3m touch systems proprietary information 21 mounting panel gasket mount the nema 4x panel gasket kit ships with the terminal. When properly installed between the bezel and a wall or panel and when the installation instructions are followed, the panel gasket provides a nema 4x/ip66 seal around the fr...
Page 58
3m touch systems proprietary information 22 3m dynapro et 3170 terminal user’s installation guide nema 4x hatch (and nema 4x extended hatch) if you need a seal over both the communication and power connections of the terminal, a nema 4x hatch kit is available from 3m touch systems. This kit comes wi...
Page 59
3m touch systems proprietary information 23 mounting desktop stand an optional stand is available from 3m touch systems for mounting the terminal on a desktop, bench, or table. Figure 12: desktop stand boom (or post) mount the boom mount kit consists of a special hatch and coupling for mounting the ...
Page 60
3m touch systems proprietary information 24 3m dynapro et 3170 terminal user’s installation guide figure 14: boom (or post) mount hatch and gasket the boom mount hatch comes with a precut opening that matches the coupling supplied with the kit. The hatch supplied in the boom mount kit is fastened wi...
Page 61: Configuring
3m touch systems proprietary information 25 chapter 5 configuring about this chapter after the et 3170 terminal is mounted firmly in place and the power and communication cables have been properly attached, it can be configured (customized) for everyday use with your application. This chapter explai...
Page 62
3m touch systems proprietary information 26 3m dynapro et 3170 terminal user’s installation guide calling up and exiting the setup screen use either the setup switch or an optional keyboard to call up the setup screen. The setup switch is a defined touch space as shown in figure 15. Figure 15: locat...
Page 63
3m touch systems proprietary information 27 configuring each touch key in the display action area identifies a keyboard key or key combination so that you can use either the touch screen or an optional keyboard. The function of each touch key is shown in table e. Figure 16: setup screen table e: tou...
Page 64
3m touch systems proprietary information 28 3m dynapro et 3170 terminal user’s installation guide ! Parameter list area (right side of the display) lists all of the setup parameters and their current values. The highlighted parameter is the one most recently changed since the terminal was last reset...
Page 65
3m touch systems proprietary information 29 configuring ! Expansion memory is volatile ! Self-tests ok, expansion memory ! For the et 3170 terminal, the term expansion memory refers to the user- accessible memory for storing screens and dynamic fonts. Changing and saving setup parameters to select a...
Page 66
3m touch systems proprietary information 30 3m dynapro et 3170 terminal user’s installation guide parameters defaults the first time that power is applied to the terminal, each setup parameter is set to its original, factory-programmed default value (see table f). Programmable parameters that can be...
Page 67
3m touch systems proprietary information 31 configuring foreground color (remote programmable) sets foreground color of the touch screen. For instructions on setting foreground color, see the application developer’s guide (available for download at www.3mtouch.Com). ! 37 (default) background color (...
Page 68
3m touch systems proprietary information 32 3m dynapro et 3170 terminal user’s installation guide nrc (remote programmable), the national replacement code parameter, enables you or the host to select a substitute set of international characters for screen display. The nrc parameter options are: ! Of...
Page 71
3m touch systems proprietary information 35 configuring address allows you to set the following addresses: ! Rs-232 (default) ! Rs-422 (rs-422 is also the setting for rs-485) a multi-drop address is not available with the et 3170 terminal. Baud rate setsthe data transmission and reception speed to o...
Page 72
3m touch systems proprietary information 36 3m dynapro et 3170 terminal user’s installation guide ! Parity sense the terminal uses either odd (default) or even parity checking: ! Odd (default): the parity bit and the data bits together contain an odd number of binary 1s. For example, for the data bi...
Page 73
3m touch systems proprietary information 37 configuring xon/xoff parameter determines how the terminal handles flow control when communicating with the host. ! On (default): when this parameter is set to on, the terminal can use either xon and xoff codes or dedicated control lines for automatic flow...
Page 74
3m touch systems proprietary information 38 3m dynapro et 3170 terminal user’s installation guide new line (remote programmable) permits the following settings: ! Off (default) ! On: the new line parameter selects the control code or codes that the terminal transmits when you press the return key an...
Page 75
3m touch systems proprietary information 39 configuring in rs-232 systems, both cts and dsr must be asserted before the transmission occurs. In three-wire systems (rx, tx, and gnd) where cts and dsr are not supported, the h/w handshake parameter must be set to none or the et 3170 terminal will not t...
Page 76
3m touch systems proprietary information 40 3m dynapro et 3170 terminal user’s installation guide the terminal tests are described in the following sections. Contact your local service representative if the terminal fails any of these tests. Figure 17: test screen: first page table k: tests availabl...
Page 77
3m touch systems proprietary information 41 configuring figure 18: test screen: second page touch panel integrity test the touch panel integrity test checks the touch cells to ensure they are working correctly. Use the following procedure to test the touch panel: 1. To begin the test, touch the touc...
Page 78
3m touch systems proprietary information 42 3m dynapro et 3170 terminal user’s installation guide figure 19: touch panel integrity test screen 3. Press the touch key positions along one row and one column in the touch cell matrix to quickly check the touch panel for opens, shorts, or decoding errors...
Page 79
3m touch systems proprietary information 43 configuring standard character set test the standard character set test provides a detailed view of the contents of the standard character set. To begin the test, touch the standard characters touch key on the test screen, or press shift/4 on the optional ...
Page 80
3m touch systems proprietary information 44 3m dynapro et 3170 terminal user’s installation guide figure 20: keyboard test screen (example) to verify correct operation of the keys, touch each key on the keyboard except the setup key. (the setup key is tested when it is pressed to exit the keyboard t...
Page 81
3m touch systems proprietary information 45 configuring if the test is activated, it can be exited by touching the setup switch on the touch screen or by pressing the setup key on the keyboard. Stored screens test you can display all the screens currently stored in expansion memory with the stored s...
Page 82
3m touch systems proprietary information 46 3m dynapro et 3170 terminal user’s installation guide the left side of the stored screens directory contains a touch key for each stored screen, identified by screen number. If there are more than 96 stored screens, the directory has multiple pages. In tha...
Page 83
3m touch systems proprietary information 47 configuring static ascii character font test the static ascii character font test provides programmers with a detailed view of the static ascii character font that resides in rom. To begin the test, touch the ascii font touch key on the second page of the ...
Page 84
3m touch systems proprietary information 48 3m dynapro et 3170 terminal user’s installation guide figure 23: static special character font test screen the test remains active until you press the keyboard setup key or touch the setup switch. This returns the terminal to the test screen. Dynamic chara...
Page 85: Maintaining
3m touch systems proprietary information 49 chapter 6 maintaining about this chapter typical tasks for maintaining the et 3170 terminal include regularly cleaning the touch screen and enclosure and replacing the fuse. Cleaning cleaning the touch screen front surface of touch screen although the fron...
Page 86
3m touch systems proprietary information 50 3m dynapro et 3170 terminal user’s installation guide back of touch screen do not attempt to clean the back of the touch screen (inside the enclosure). This task may be performed only by qualified service personnel. Cleaning the enclosure exterior clean th...
Page 87
3m touch systems proprietary information 51 maintaining for terminal with ac fixed field wiring to change the fuse of a terminal that has fixed field wiring, follow these steps: 1. Turn off the power to the terminal at the source. 2. Find the fuse on the back of the terminal (figure 5 on page 16). 3...
Page 89: Troubleshooting
3m touch systems proprietary information 53 chapter 7 troubleshooting about this chapter if you have trouble with your terminal, try the troubleshooting strategies outlined below. Troubleshooting strategies warning to reduce the risks associated with electrical shock which, if not avoided, could res...
Page 90
3m touch systems proprietary information 54 3m dynapro et 3170 terminal user’s installation guide terminal powers up but the display does not seem to function. 1. If the display activity configuration was changed recently, press the setup key or setup switch to change display activity configuration ...
Page 91
3m touch systems proprietary information 55 appendix a specifications and certifications enclosure components the enclosure of the 3m dynapro tm et 3170 terminal consists of the following main components: ! Bezel/touch screen/display assembly ! Core electronics assembly ! Main enclosure ! Rear acces...
Page 92
3m touch systems proprietary information 56 3m dynapro et 3170 terminal user’s installation guide enclosure dimensions figure 25: enclosure dimensions imperial metric active touch area (wide x high) 10.5" x 9.2" 267 mm x 234 mm overall size (wide x high x deep) 14.0" x 12.55" x 5.48" 356 mm x 319 mm...
Page 93
3m touch systems proprietary information 57 specifications and certifications cutout dimensions chemical resistance the microtouch tm near field imaging tm (nfi) touch screen is made of glass and will withstand most chemicals and their concentrations that do not corrode glass. If the touch screen’s ...
Page 94
3m touch systems proprietary information 58 3m dynapro et 3170 terminal user’s installation guide display specifications serial communications ac power supply fuse memory non-volatile memory for storing frequently used screens and dynamic character fonts. Battery lithium. Operating life of more than...
Page 95
3m touch systems proprietary information 59 specifications and certifications operating conditions non-operating conditions documentation the following documents ship with the terminal: ! Et 3170 terminal user’s installation guide and service guide ! Installing the nema 4x panel gasket these documen...
Page 96
3m touch systems proprietary information 60 3m dynapro et 3170 terminal user’s installation guide dust and moisture resistance fcc compliance this equipment has been tested and found to comply with the limits for a class a digital device, pursuant to part 15 of the fcc rules. These limits are design...
Page 97
3m touch systems proprietary information 61 specifications and certifications electromagnetic emission standards product certifications en55022 class a ices-003 class a fcc cfr 47, part 15, subpart b, class a ul information technology equipment — united states c-ul information technology equipment —...
Page 99
3m touch systems proprietary information 63 appendix b request identification command about the request identification command [da] (remote) the request tcs identification command allows the host computer to determine the following information about the tcs: ! Type of tcs with which it is communicat...
Page 100
3m touch systems proprietary information 64 3m dynapro et 3170 terminal user’s installation guide is a reserved parameter. Example an example of a tcs identification sequence sent to the host in response to this command is: [2;10;98304;0;0;0c the tcs type is model 1030 (2), with firmware version 1.0...
Page 101: Terms and Acronyms
3m touch systems proprietary information 65 appendix c terms and acronyms terms the following terms relate to the et 3170 terminal. This term refers to: bezel the front rim of the terminal, containing the touch screen and the faceplate. Boom mount an extended hollow arm on the end of which the termi...
Page 102
3m touch systems proprietary information 66 3m dynapro et 3170 terminal user’s installation guide abbreviations and acronyms the following abbreviations and acronyms are used in this manual. Ascii american standard code for information interchange bios basic input output system cpu central processin...
Page 104: Index
3m touch systems proprietary information 69 index a abbreviations and acronyms ! 66 ac power supply ! 14 address parameter ! 35 auto wrap parameter ! 38 b backlights replacing ! 50 battery operating life of ! 58 boom/post mounting ! 23 c cleaning enclosure ! 50 touch screen ! 49 communications types...
Page 105
3m touch systems proprietary information 70 3m dynapro et 3170 terminal user’s installation guide s safety notices ! I standards ! 59 security screws ! 18 serial communication ! 12 setup parameters changing ! 29 saving ! 29 volatility of ! 29 setup screen ! 25 soft reset ! 29 specifications ! 55 dus...
Page 108: Et 3170 Terminal
Et 3170 terminal (series b) service guide 3m touch systems proprietary information read and understand all safety information before installing and using this product..
Page 109
Copyright this manual is © 3m 2002. All rights reserved. Reproduction of the contents of this copyrighted manual in whole or in part, by any means, electronic or mechanical, for any purpose, without written permission of 3m touch systems, a subsidiary of 3m, is prohibited. Notice given the variety o...
Page 110: Important Safety Information
3m touch systems proprietary information i important safety information read and understand all safety information before using the 3m dynapro tm et 3170 terminal. Follow all instructions marked on the product and described in this document. Pay close attention to the statement of intended use and t...
Page 111
3m touch systems proprietary information ii 3m dynapro et 3170 terminal service guide warning to reduce the risks associated with electrical shock or fire which, if not avoided, could result in death or serious injury and/or property damage: ! Provide a clean, reliable grounding. ! When installing t...
Page 112
3m touch systems proprietary information iii important safety information safety labels the following safety symbols appear on your 3m dynapro industrial product and its packaging materials: symbol meaning consult user instructions. Caution: risk of electric shock. Caution: item is susceptible to el...
Page 114: Contents
3m touch systems proprietary information v contents chapter 1 about the service guide ................................................ 1 who should read this service guide ...................................................... 1 what it’s about ..........................................................
Page 116: About The Service Guide
3m touch systems proprietary information 1 chapter 1 about the service guide who should read this service guide the et 3170 terminal service guide is for qualified service personnel who need to make adjustments inside the enclosure of the 3m dynapro tm et 3170 terminal. What it’s about this service ...
Page 118: Setting Jumpers
3m touch systems proprietary information 3 chapter 2 setting jumpers about this chapter this chapter explains how to: ! Set jumpers on the logic board for rs-232, rs-422, and rs-485 communications. To be sure that you have the correct version of the logic board, check the series number of the termin...
Page 119
3m touch systems proprietary information 4 3m dynapro et 3170 terminal service guide to set the jumpers on the logic board: 1. Put on a grounding strap. 2. Disconnect power to the terminal. 3. Remove security screws, if there are any installed. 4. Use the allen key to open the enclosure (figure 1), ...
Page 120
3m touch systems proprietary information 5 setting jumpers figure 2: location of logic board jumpers 7. Using needle nose pliers, pull the jumper off the header. 8. Use the pliers to install the jumper at another position on the header (figure 3). The position of the jumper will configure the serial...
Page 121
3m touch systems proprietary information 6 3m dynapro et 3170 terminal service guide setting jumpers on the i/o filter board this procedure is necessary only if you wish to add jumpers on the i/o filter board. These jumpers add 100 ohm termination resistors across the tx+, tx- or rx+, rx- signal lin...
Page 122
3m touch systems proprietary information 7 setting jumpers 6. Locate the two headers marked j1 and j2. They are found on the component side of the i/o filter board. Figure 4: location of jumpers on i/o filter board 7. Using needle nose pliers, push the first jumper on j1 and the second jumper on j2....
Page 123
3m touch systems proprietary information 8 3m dynapro et 3170 terminal service guide connector pin-outs and cable diagrams the following illustrations show the suggested connector pin-outs and cable diagrams for rs-422 and rs-485 communications. Your host system may have a different pin-out than pre...
Page 124
3m touch systems proprietary information 9 setting jumpers rs-232 communication use a standard cable for rs-232 communications. Alternatively, make a cable for rs-232 communications using the pin-out shown in table a. The maximum cable length is 50 feet. Rs-422 communication to make a cable for rs-4...
Page 125
3m touch systems proprietary information 10 3m dynapro et 3170 terminal service guide rs-485 communication to make a cable for rs-485 communications, use the pin-out shown in table c. For maximum cable length, refer to the eia rs-485 specification standard. Table c: com a rs-485 connector pin-out (h...