3M Peltor DECT-Com II User Manual

Other manuals for Peltor DECT-Com II: Instruction Manual

Summary of Peltor DECT-Com II

  • Page 1

    Peltor ™ dect-com ii ™ the sound solution dect 1.8 ghz system.

  • Page 2

    1 antenna function indication ring headset connector [m] mode [+] up [–]down led (light emitting diode) ptt1 push-to-talk 1 ptt2 push-to-talk 2 ptt3 push-to-talk 3 attachment clip quick guide – peltor dect-com ii button function [m] switch dect-com ii unit on/off select function in the menu [+] incr...

  • Page 3: Index

    2 3 index 1 introduction 2 main units 2.1 switch a main unit on and off 2.2 base/portable unit 2.3 portable unit 2.4 log in to or out of a conference 2.5 main units controls 2.6 technical information, main units dc2811, dc2812, dc2815 3 power supply 3.1 batteries 3.2 fixed mounted power supply 4 ant...

  • Page 4: Peltor Dect-Com Ii

    2 3 peltor dect-com ii 1. Introduction peltor™ dect-com ii™ is a wireless duplex intercom system, operating on the 1.8 ghz dect-frequencies, which are license free in most countries. The products in the peltor dect-com ii family offer simple and efficient wireless duplex communication with up to 9 a...

  • Page 5

    4 5 when a base unit is ready for use, a voice message “base, group 1” is given. The led on the unit is flashing slower. When a portable unit is ready for use, a voice message “group 1” is given. The led on the unit is lit. Notice: all units are always started in listen only mode in group 1. 2.1.1 s...

  • Page 6

    4 5 notice: all units are always started in listen only mode in group 1. Last used alternative (base or portable) is remembered between sessions. 2.2.4 make a base unit ready for portables to be registered each portable unit should be registered to a base unit to be part of a dect-com ii conference....

  • Page 7

    6 7 notice: all main units are delivered open for registration from factory and a dect-com ii system can be started directly “out of the box” by first starting a base/portable unit as a base as described above and after that, all portable units, sequentially and continually, as described above. Afte...

  • Page 8

    6 7 2.3.7 select another base from a portable unit g in volume mode on a portable unit in listen mode; double press on the [m] button to enter base selection mode. A voice confirmation “base” is given, urging to select a base. G press [+] or [–] to cycle through the numbers of available bases and an...

  • Page 9

    8 9 2.5 main units controls 2.5.1 mode the mode button [m] controls functions of the unit. G step forward through the mode steps in the menu by pressing briefly on the [m] button. Voice messages “vox”, “microphone”, “volume” are given respectively to confirm the actual mode. G step backwards through...

  • Page 10

    8 9 2.5.1.3 microphone one of four microphone types (carbon, electret, dynamic or low impedance) can be chosen by the user, to adapt the amplification in the dect-com unit to the electrical signal level of the actually used microphone. G in microphone mode, use the [+] and [–] buttons to set the use...

  • Page 11

    10 11 2.6 technical information, main units dc2811, dc2812, dc2815 frequency range: 1880 – 1900 mhz operation mode: duplex output power: max. 250 mw, average 10 mw (portable) / 120 mw (base) current consumption: base/portable unit dc2812, dc2815 as base typ. 320 ma (4 portables system) as portable; ...

  • Page 12

    10 11 3.1 batteries 3.1.1 rechargeable battery pack a peltor rechargeable battery pack dc2033 is needed for the main units. 3.1.1.1 charging a battery pack a rechargeable nimh-battery pack dc2033 has to be charged in a main unit placed in a peltor charger/holder dc2064. It is sealed according to ip4...

  • Page 13

    12 13 3.1.1.3 technical information, dc2033 chemical structure: nimh nominal voltage: 3.6 v nominal capacity: 2100 mah usage temperature: -25°c to +55°c storage temperature: -55°c to +70°c notice: remove the battery pack from the main unit if it should not be used in a month’s time, or longer. Charg...

  • Page 14

    12 13 3.1.3 external battery carrier the external battery carrier dc2032 can be mounted on the back of the main unit. It offers extra energy for longer usage time. Any standard batteries (6 x 1.5 volts, type aa) or rechargeable batteries (6 x 1.2 volts, type aa) can be used. Notice: it is recommende...

  • Page 15: Antennas

    14 15 tighten the screw with a suitable tool. (caution: when tightening the screw, do not use your fingernail, it can be broken!) 3.1.3.3 rechargeable batteries in external battery carrier any rechargeable batteries in the battery carrier dc2032 must be taken out to be charged with an appropriate ex...

  • Page 16: Extension Of The System

    14 15 4.1 general antenna the external antenna dc2041, which is delivered with all dect-com ii main units, should normally be mounted on the main unit together with a plastic ring (see 4.1.1 unit function indicators below). 4.1.1 unit function indicators a package dc2048 with 3 differently coloured ...

  • Page 17

    16 17 in the list of accessories and spare parts (see below) you will find adapter cables for some common communication radios, a general telephone cable and a cable for ground mechanic. 5.1.1 further external equipment on demand, extension base/portable unit dc2815 can be equipped with a second con...

  • Page 18: Approvals

    16 17 6. Accessories and spare parts pleasecontactyourauthorized peltor dect-com ii dealer* ) dc2031 battery lid for use with 3xaa standard batteries in main unit. Dc2032 battery carrier for 6xaa auxiliary batteries (excl. Batteries) . Dc2033 rechargeable nimh-accumulator (2100 mah) dc2035 screw for...

  • Page 19: Warranty

    18 19 8. Warranty 3m guarantee conformity with the contractual specifications of the quality and performance of the goods. Full information about the peltor warranty is available on request from your local 3m office. “non-conformity goods“ should be returned to your authorized peltor dect-com ii dea...

  • Page 20

    18 19.

  • Page 21

    20

  • Page 22

    3m occupational health & environmental safety division 3m svenska ab box 2341, se-331 02 värnamo sweden phone: +46 (0) 370 65 65 65 fax: +46 (0) 370 65 65 99 email: peltorcommunications@mmm.Com internet: www.3m.Com/peltorcomms please recycle. Printed in sweden. © 3m 2010. All rights reserved. Fp####...