13
3.1.1.3 TECHNICAL INFORMATION, DC2033
Chemical structure:
NiMH
Nominal Voltage:
3.6 V
Nominal Capacity:
2100 mAh
Usage temperature:
-25°C to +55°C
Storage temperature:
-55°C to +70°C
Notice: Remove the battery pack from the main unit if it should not be
used in a month’s time, or longer.
Charging temperature:
+5°C to +45°C
Charging time:
Up to 12 hours at 20°C
Notice: It is normal that the battery may become warm during charging or use. At first
time use, or after long time storage, it may take three to five full charging cycles to reach
full battery capacity.
Battery life time:
Approximately 250 charge cycles.
Notice: The battery capacity will decrease after many recharge cycles
or as the battery pack ages.
Weight:
Approximately 100 g
3.1.2 CHARGER/HOLDER DC2064
The battery pack DC2033 must be charged in a main unit; DC2811, DC2812 or DC2815.
Charging is indicated with a red LED on the charger. When the LED turns green, the charging is finished. An initial flashing
red/green LED indicates that the charger unit is detecting/analysing a newly inserted battery.
3.1.2.1 TECHNICAL DATA, CHARGER/HOLDER DC2064
Input voltage: 9 V DC
Charging time of DC2033 in a main unit: Up to approximately 12 hours
Charging temperature interval: +5°C to +45°C
NOTICE! No other power source than the Peltor DECT-Com II mains adapter DC2061 (included in the package at delivery)
may be used together with the charger/holder DC2064! It is equipped with exchangeable European, UK and US type mains
connectors, for the input of 100 ─ 240 Volt AC, 50/60 Hz.