A&D UA-767NFC Instruction Manual

Other manuals for UA-767NFC: Instruction Manual
Manual is about: Digital Blood Pressure Monitor

Summary of UA-767NFC

  • Page 1

    Digital blood pressure monitor model ua-767nfc instruction manual 1wmpd4002380

  • Page 2: Contents

    1 contents dear customers.................................................................... 2 preliminary remarks ............................................................. 2 precautions........................................................................... 2 parts identification..............

  • Page 3: Dear Customers

    2 dear customers congratulations on purchasing a state-of-the-art a&d blood pressure monitor, one of the most advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen. We recommend that you read through this manual caref...

  • Page 4: Parts Identification

    3 parts identification battery compartment arm cuff dc jack air connector plug air socket pressure bar indicator memory systolic pressure diastolic pressure pulse rate battery indicator heart mark 1.5v batteries (r6p, lr6 or aa) clock display clock button i.H.B. Symbol (irregular heartbeat symbol) s...

  • Page 5: Symbols

    4 symbols symbols that are printed on the device case symbols function / meaning recommended action standby and turn the device on. Sys. Systolic blood pressure in mmhg dia. Diastolic blood pressure in mmhg pul./min. Pulse per minute battery installation guide direct current sn serial number 2010 da...

  • Page 6: Symbols

    5 symbols symbols function / meaning recommended action full battery the battery power indicator during measurement. Low battery the battery is low when it blinks. Replace all batteries with new ones when the mark blinks. Unstable blood pressure due to movement during measurement. Take another measu...

  • Page 7: Operation Mode

    6 operation mode 1. Normal measurement press the start button. Blood pressure is measured and the data is stored in memory. 2. Memory function this monitor can store the last 100 measurements in memory. When the measurement exceeds 100, the oldest data will be deleted automatically and the most rece...

  • Page 8: Using The Monitor

    7 using the monitor installing / changing the batteries 1. Slide the battery cover up to open it. 2. Remove the used batteries and insert new batteries into the battery compartment as shown, taking care that the polarities (+ and -) are correct. Use only r6p, lr6 or aa batteries. 3. Slide the batter...

  • Page 9: Using The Monitor

    8 press press and hold press and hold 12-hour clock 24-hour clock using the monitor notes on the built-in clock the monitor displays the clock as long as power is connected. Adjust the clock prior to use. The current clock setting will be cleared if the batteries are removed, or power is not connect...

  • Page 10: Using The Monitor

    9 press and hold year month day hour minute 12-hour clock 24-hour clock using the monitor adjusting the clock 1. Press and hold the button until the year starts blinking. 2. Select the year using the button. Press the button to set the current year and move to month/day selection. The date can be se...

  • Page 11: Using The Monitor

    10 using the monitor selecting the correct cuff size using the correct cuff size is important for an accurate reading. If the cuff is not the proper size, the reading may yield an incorrect blood pressure value. The arm size is printed on each cuff. The index and proper fit range, on the cuff, tell ...

  • Page 12: Using The Monitor

    11 using the monitor symbols that are printed on the cuff symbols function/meaning recommended action artery position mark set the mark on the artery of the upper arm or in line with the ring finger on the inside of the arm. ▲ index ref catalog number proper fit range for adult cuff it's printed on ...

  • Page 13: Measurements

    12 start measurements before measurement, read “notes for proper measurement” on the next page. Normal measurement 1. Place the cuff on the arm (preferably the left arm). Sit quietly during measurement. 2. Press the start button. The number of data stored in memory is displayed. Zero (0) is displaye...

  • Page 14: Measurements

    13 start measurements measurement with the desired systolic pressure model ua-767nfc is designed to detect the pulse and to inflate the cuff to a systolic pressure level automatically. Use this method when re-inflation occurs repeatedly or when the results are not displayed even if the pressure decr...

  • Page 15: Memory Data Transmission

    14 near field communication (nfc) function to transmit data to or from the blood pressure monitor, communication devices that comply with the communication specifications of the blood pressure monitor are required. Examples of communication devices that comply nfc-enabled cellular phone personal com...

  • Page 16: Pressure Bar Indicator

    15 caution on using the nfc function the ua-767nfc blood pressure monitor has an nfc forum type 3 tag wireless interface module built in. When the monitor is used near wireless communication devices which use the same frequency as that of the monitor (13.56 mhz) or use its harmonic frequencies, elec...

  • Page 17: About Blood Pressure

    16 about blood pressure what is hypertension and how is it controlled? Hypertension, an abnormally high arterial blood pressure, if left unattended, can cause many health problems including stroke and heart attack. Hypertension can be controlled by altering lifestyle, avoiding stress, and with medic...

  • Page 18: Troubleshooting

    17 troubleshooting problem possible reason recommended action batteries are drained. Replace all batteries with new ones. Nothing appears on the display, even when the power is turned on. Battery terminals are not in the correct position. Reinstall the batteries with negative and positive terminals ...

  • Page 19: Maintenance

    18 maintenance do not open the device. It uses delicate electrical components and an intricate air unit that could be damaged. If you cannot fix the problem using the troubleshooting instructions, contact the authorized dealer in your area or our customer service department. The a&d customer service...

  • Page 20

    A&d company, limited 1-243 asahi, kitamoto-shi, saitama 364-8585 japan telephone: [81] (48) 593-1111 fax: [81] (48) 593-1119 a&d instruments ltd. Unit 24/26 blacklands way, abingdon business park, abingdon, oxfordshire ox14 1dy united kingdom telephone: [44] (1235) 550420 fax: [44] (1235) 550485 a&d...