A&D UA-767NFC Instruction Manual

Other manuals for UA-767NFC: Instruction Manual
Manual is about: Digital Blood Pressure Monitor

Summary of UA-767NFC

  • Page 1

    Digital blood pressure monitor model ua-767nfc instruction manual original manuel d ’ instructions traduction manual de instrucciones traducción manuale di istruzioni traduzione bedienungsanleitung Übersetzung 1wmpd4002380d.

  • Page 2: Contents

    English 1 contents dear customers ............................................................................................ 1 preliminary remarks...................................................................................... 2 precautions.......................................................

  • Page 3: Preliminary Remarks

    English 2 preliminary remarks this device conforms to the european directive 93/42 eec for medical products. This is made evident by the mark of conformity. (0123: the reference number to the involved notified body) the device is designed for use on adults only, not newborns or infants. Environment ...

  • Page 4: Parts Identification

    English 3 artery position mark pressure bar indicator memory systolic pressure diastolic pressure pulse rate clock display clock mark battery indicator heart mark i.H.B. Symbol (irregular heartbeat symbol) 1.5v batteries (r6p, lr6 or aa) start button proper fit range index mark clock button battery ...

  • Page 5: Symbols

    English 4 symbols symbols that are printed on the device case symbols function / meaning standby and turn the device on. Sys. Systolic blood pressure in mmhg dia. Diastolic blood pressure in mmhg pul./min. Pulse per minute battery installation guide direct current type bf: device, cuff and tubing ar...

  • Page 6: Symbols

    English 5 symbols symbols function / meaning recommended action full battery the battery power indicator during measurement. Low battery the battery is low when it blinks. Replace all batteries with new ones when the mark blinks. Unstable blood pressure due to movement during measurement. Take anoth...

  • Page 7: Operation Mode

    English 6 operation mode 1. Normal measurement press the start button. Blood pressure is measured. 2. Memory function when the memory setting is 100: this device will store the last 100 measurements in memory. When the measurement exceeds 100, the oldest data will be deleted automatically and the mo...

  • Page 8: Using The Monitor

    English 7 using the monitor installing / changing the batteries 1. Slide the battery cover up to open it. 2. Remove the used batteries and insert new batteries into the battery compartment as shown, taking care that the polarities (+ and -) are correct. Use only r6p, lr6 or aa batteries. 3. Slide th...

  • Page 9: Using The Monitor

    English 8 using the monitor connecting the air hose insert the air connector plug into the air socket firmly. Setting and adjusting the clock set or adjust the clock prior to use. 1. Press and hold the button until the year starts blinking. When inserting the batteries or connecting the ac adapter, ...

  • Page 10: Notes On The Built-In Clock

    English 9 notes on the built-in clock the device displays the clock as long as power is connected. Adjust the clock prior to use. During measurement, the clock adjustment is not available. When adjusting the clock, press the button to increase the value by one, or press and hold the button to change...

  • Page 11: Using The Monitor

    English 10 using the monitor selecting the correct cuff size using the correct cuff size is important for an accurate reading. If the cuff is not the proper size, the reading may yield an incorrect blood pressure value. The arm size is printed on each cuff. The index and proper fit range, on the cuf...

  • Page 12: Using The Monitor

    English 11 using the monitor applying the arm cuff 1. Wrap the cuff around the upper arm, about 1 - 2 cm above the inside of the elbow, as shown. Place the cuff directly against the skin, as clothing may cause a faint pulse, and result in a measurement error. 2. Constriction of the upper arm, caused...

  • Page 13: Measurements

    English 12 start at heart level measurement in progress systolic pressure diastolic pressure pulse rate exhausts remaining air automatically press pressurizing zero display starts inflation all of the display segments displayed measurements before measurement, read “notes for proper measurement” on ...

  • Page 14: Measurements

    English 13 measurements measurement with the desired systolic pressure model ua-767nfc is designed to detect the pulse and to inflate the cuff to a systolic pressure level automatically. Use this method when re-inflation occurs repeatedly or when the results are not displayed even if the pressure de...

  • Page 15: Notes For Proper Measurement

    English 14 notes for proper measurement sit down in a comfortable position. Place your arm on a table with your palm facing upward and the cuff at the same level as your heart. Relax for about five to ten minutes before taking a measurement. If you are excited or depressed by emotional stress, the m...

  • Page 16: Displaying The Memory Data

    English 15 press to increase the memory number by one. Press to decrease the memory number by one. Press to return to the clock display. Press and hold 1.5 seconds 1.5 seconds 1.5 seconds clock display memory number date time start start near field communication (nfc) function to transmit data to or...

  • Page 17

    English 16 data transmission 100 blinks. Data transmission initiate communication initiate communication 0 blinks. Switching the memory setting while the device displays the clock, hold the communication symbol of the nfc-enabled communication device close to the communication area ( ) of the device...

  • Page 18

    English 17 transmitting the memory data while the device displays the clock, hold the communication symbol of the nfc-enabled communication device close to the communication area ( ) of the device until “ ” appears. The memory data transmission is performed. If the clock of the device is not correct...

  • Page 19: Pressure Bar Indicator

    English 18 what is an irregular heartbeat the ua-767nfc provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs. An irregular heartbeat is defined as a heartbeat that varies by 25% from the average of all heartbeats during the blood pressure measurement. It is im...

  • Page 20: About Blood Pressure

    English 19 about blood pressure what is hypertension and how is it controlled? Hypertension, an abnormally high arterial blood pressure, if left unattended, can cause many health problems including stroke and heart attack. Hypertension can be controlled by altering lifestyle, avoiding stress, and wi...

  • Page 21: Troubleshooting

    English 20 troubleshooting problem possible reason recommended action batteries are drained. Replace all batteries with new ones. Nothing appears on the display, even when the power is turned on. Battery terminals are not in the correct position. Reinstall the batteries with negative and positive te...

  • Page 22: Maintenance

    English 21 maintenance do not open the device. It uses delicate electrical components and an intricate air unit that could be damaged. If you cannot fix the problem using the troubleshooting instructions, contact the authorized dealer in your area or our customer service department. The a&d customer...

  • Page 23

    English 22 useful life device: 5 years (when used six times a day) cuff: 2 years (when used six times a day) wireless communication nfc wireless interface module accessory ac adapter the adapter is to connect the device to a power source at home. Tb-233 please contact your local a&d dealer for purch...

  • Page 24

    1-243 asahi , kitamoto-shi, saitama 364-8585, japan telephone: [81] (48) 593-1111 fax: [81] (48) 593-1119 a&d instruments limited unit 24/26 blacklands way, abingdon business park, abingdon, oxfordshire ox14 1dy united kingdom telephone: [44] (1235) 550420 fax: [44] (1235) 550485 a&d engineering, in...