AAS EPOC-POE-100-IP User Manual - Application Diagram
4
Application Diagram
..
Hardware Installation
..
1.
Please turn off the signal source and the device's power; installation with power still
on may damage the device.
2.
Use network cable to connect PoE IN port of SV-Unit and PoE Ethernet switch (if it's
not PoE switch, then need to use 48-57V power supply for SV-Unit).
3.
Use another network cable or coaxial cable to connect Ethernet port of SV-Unit and
Ethernet port of IPC-Unit
4.
Use a network cable to connect IP camera with PoE OUT port of IPC-Unit.
5.
Check if the installation is correct and device is good; make sure all the connections
are reliable and power for the system.
6.
Make sure every network device has power supply and is working normally.
** Table 1 (The test data in Table 1 based on the test method in Application Diagram shown above)
Power Supply
PoE Ethernet Power Supply
54V DC Power Supply
SV IPC Cable
75-5
CAT5e
75-5
CAT5e
100m
Bandwidth (Mbps)
92.6
91.2
92.6
91.2
Load Capacity (W)
16.1
17.2
23
23
200m
Bandwidth (Mbps)
91
84.2
91
84.2
Load Capacity (W)
10
12
17
22
300m
Bandwidth (Mbps)
90.8
74.5
90.8
74.5
Load Capacity (W)
8
9.1
12
16
400m
Bandwidth (Mbps)
90.5
55.7
90.5
55.7
Load Capacity (W)
5
6.5
10
12
500m
Bandwidth (Mbps)
83.7
/
83.7
/
Load Capacity (W)
4.5
/
8
/
**Picture 1