  • Page 1

    Installation, administration and maintenance of the sip-dect solution aastra telecom © june 2007 - all rights reserved no part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or information storage and retrie...

  • Page 2

    Installation, administration and maintenance aastra telecom page: 2 (47) table of contents 1 overview ........................................................................................................................................................... 4 1.1 p urpose ..............................

  • Page 3

    Installation, administration and maintenance aastra telecom page: 3 (47) 5.1 c ommunications r egulation i nformation for a astra p hone 142 us ........................................ 44 5.2 c ommunications r egulation i nformation for rfp 32 or rfp 34 (na) ...................................... 45.

  • Page 4

    Installation, administration and maintenance aastra telecom page: 4 (47) 1 overview 1.1 purpose this document describes the installation, configuration and maintenance of the aastra sip-dect solution. 1.2 abbreviations and definitions 1.2.1 abbreviations ac authentication code adpcm adaptive differe...

  • Page 5

    Installation, administration and maintenance aastra telecom page: 5 (47) • the standard (ets 300 175) essentially specifies the air interface, known as the radio interface. Voice and data can both be transmitted via this interface. • its technical key characteristics for europe are: • frequency rang...

  • Page 6

    Installation, administration and maintenance aastra telecom page: 6 (47) handover handover a handover is similar to roaming, but occurs during an ongoing call. A handover normally takes place “in the background”, without disrupting the call (seamless handover). Ipei international portable equipment ...

  • Page 7

    Installation, administration and maintenance aastra telecom page: 7 (47) /9/ rfc 2833, rtp payload for dtmf digits, telephony tones and telephony signals, may 2000 /10/ rfc 3261, session initiation protocol (sip), june 2002 /11/ rfc 3264, an offer/answer model with session description protocol (sdp)...

  • Page 8

    Installation, administration and maintenance aastra telecom page: 8 (47) 2 introduction 2.1 about the aastra sip-dect solution the aastra sip-dect solution comprises the following components: • aastra sip-dect access points (also known as radio fixed parts (rfp’s)) being distributed over an ip netwo...

  • Page 9

    Installation, administration and maintenance aastra telecom page: 9 (47) 2.2 about the access points (rfp’s) aastra has two versions of access points, indoor and outdoor models rfp32 and rfp34 respectively. Rfp references apply to both models. In general all rfps have the same hardware and software ...

  • Page 10

    Installation, administration and maintenance aastra telecom page: 10 (47) rfp only mode within this mode the rfp converts ip protocol to dect protocol and then transmits the traffic to and from the handsets over a dect time slot. On air the rfp has 12 available time slots, 8 can have associated dsp ...

  • Page 11

    Installation, administration and maintenance aastra telecom page: 11 (47) 2.3 openmobility manager the openmobility manager (omm) performs the following tasks: • signalling gateway (sip dect). • media stream management. • managing sync-over-air functions between rfps. • facilitating system configura...

  • Page 12

    Installation, administration and maintenance aastra telecom page: 12 (47) media server media gateway signalling rfp control interface rtp/rtcp omm (rfp in omm mode) a call from one pp to another that resides on the same rfp will loop back within the rfp, if no media gateway is involved. So the call ...

  • Page 13

    Installation, administration and maintenance aastra telecom page: 13 (47) if the pp user is moving, the pp detects that another rfp has a better signal strength and, therefore, it starts the handover process. The media stream from the ip phone cannot move to the secondary rfp, so the primary rfp use...

  • Page 14

    Installation, administration and maintenance aastra telecom page: 14 (47) media server media gateway signalling rfp control interface rtp/rtcp sip-phone omm (rfp in omm mode) primary rfp new secondary rfp 2.5 rfp synchronization to guarantee a seamless handover if a caller moves from one rfp zone of...

  • Page 15

    Installation, administration and maintenance aastra telecom page: 15 (47) an ip dect installation is more reliable if a rfp can receive the signal from more than only one rfp, because the other signals are also used for synchronization. R 111 r 110 r 109 r 108 r 106 r 101 r 102 r 103 r 104 r 105 r 1...

  • Page 16

    Installation, administration and maintenance aastra telecom page: 16 (47) 2.7 about the portable parts portable part (pp) is dect standard terminology and in the context of the sip-dect solution is interchangeable with aastra dect 142 handset. Please be aware of differences in regulatory requirement...

  • Page 17

    Installation, administration and maintenance aastra telecom page: 17 (47) 3 installation and configuration to establish and maintain an ip dect installation, a network infrastructure is assumed, which comprises at least the following components: • rfps • pps • ip pbx/media server (e.G. Asterisk) the...

  • Page 18

    Installation, administration and maintenance aastra telecom page: 18 (47) application after starting the application image the rfp checks the local network settings in its internal flash memory once again. If no settings are available or if they are disabled it starts a dhcp client to determine the ...

  • Page 19

    Installation, administration and maintenance aastra telecom page: 19 (47) 3.1.3.1.2 dhcp offer the dhcp client selects the dhcp server according to the following rules: • the public options (code 224) has a value equal to the string “openmobility”. Or • the file field in the dhcp message has a sub s...

  • Page 20

    Installation, administration and maintenance aastra telecom page: 20 (47) yiaddr ip-address of the ip-rfp yes code 66 parameter named boot server host name with value as the ip-address of the tftp server yes code 67 parameter named bootfile name with value of the path (optional) and name of the appl...

  • Page 21

    Installation, administration and maintenance aastra telecom page: 21 (47) each application sw comes with the latest released booter sw. The application sw will update the booter automatically as long as the major release number of the booter sw has not changed, e.G booter sw 2.1.2 will not be automa...

  • Page 22

    Installation, administration and maintenance aastra telecom page: 22 (47) state led state remarks booter (tftp) red flashing 2.5 hz downloading the application image application (dhcp) orange on launching dhcp request and waiting for dhcp reply application (init) green flashing 0.5 hz rfp is initial...

  • Page 23

    Installation, administration and maintenance aastra telecom page: 23 (47) 3.1.6 state graph of the start up phases start-up wait for link up led red on retry wait for 60 seconds led red flashing 0,25 hz application init application connect to omm application synchronize dect application up & running...

  • Page 24

    Installation, administration and maintenance aastra telecom page: 24 (47) 3.2 static local configuration of an rfp as an alternative to dhcp configuration, the rfps/omm may be individually statically configured using the om configurator tool. For a static local configuration you must use the java co...

  • Page 25

    Installation, administration and maintenance aastra telecom page: 25 (47) the recommended parameters that should be configured through the openmobility configurator tool are: • use local configuration: yes • ip address • subnet • tftp server address • tftp file name • omm ip address • router address...

  • Page 26

    Installation, administration and maintenance aastra telecom page: 26 (47) 3.3 configuring the openmobility manager the omm runs on a designated rfp within a sip-dect deployment. The omm is designated via dhcp options or statically declared via the om configurator tool. All other rfps in the deployme...

  • Page 27

    Installation, administration and maintenance aastra telecom page: 27 (47) after login there are the following options available: ƒ configuration of general sip-dect system parameters. ƒ administration of the attached rfps. ƒ administration of the pps. If no user action takes place the omm logs out t...

  • Page 28

    Installation, administration and maintenance aastra telecom page: 28 (47) 3.3.2.1 system settings the system settings cover global settings for the openmobility manager like: • system name • dect authentication code. The authentication code is used during initial pp subscription as a security option...

  • Page 29

    Installation, administration and maintenance aastra telecom page: 29 (47) • after a specific time to update date and time 3.3.2.1.1 restarting the omm to restart the omm select “system settings” from the navigation tree and then select ‘restart’. There is also the option to reset the configuration d...

  • Page 30

    Installation, administration and maintenance aastra telecom page: 30 (47) if encryption is enabled and another rfp variant connects to the omm, its dect air interface will not be activated. Note: the pps have to support dect encryption which is not a mandatory feature. 3.3.2.1.3 regulatory domain to...

  • Page 31

    Installation, administration and maintenance aastra telecom page: 31 (47) you have a session border controller in your network, then you would normally set its address here. Optional. • outbound proxy port the proxy port on the proxy server to which the omm sends all sip messages. Optional. • explic...

  • Page 32

    Installation, administration and maintenance aastra telecom page: 32 (47) 3.3.2.3 user account after initial installation or after removing the configuration file the openmobility service is accessible via a build-in user account with user “ omm ” and password “ omm ”. These settings which are case ...

  • Page 33

    Installation, administration and maintenance aastra telecom page: 33 (47) openmobility manager startup. The “default” button sets all time zones back to the default values and deletes the changed time zone rules in the configuration file. With the “configure time zone” dialog the standard time and t...

  • Page 34

    Installation, administration and maintenance aastra telecom page: 34 (47) 3.3.2.5 backup the web service interface allows to save a copy of the current configuration on the local host (host where the browser application is executed) as well as to restore an older configuration. Restoring a previousl...

  • Page 35

    Installation, administration and maintenance aastra telecom page: 35 (47) when the rfps are connecting the omm they submit their hw type. This type is displayed on the rfp list web page. New rfps can be added to the system by pressing the “new” button. A popup window appears providing the configurat...

  • Page 36

    Installation, administration and maintenance aastra telecom page: 36 (47) 3.3.3.1 dect configuration the dect functionality for each rfp can be switched on/off. If dect is active the rfp can be added to a cluster. 3.3.3.2 states of a rfp for each rfp the state of the dect subsystem is displayed. The...

  • Page 37

    Installation, administration and maintenance aastra telecom page: 37 (47) message. Moreover a global error message is displayed on the rfp list web page if at least one version mismatch has been found..

  • Page 38

    Installation, administration and maintenance aastra telecom page: 38 (47) 3.3.4 configuration of portable parts at the portable parts web page all configured dect handsets are sorted by their number. To keep the list concise, the complete list is split up into sub lists containing up to 100 handsets...

  • Page 39

    Installation, administration and maintenance aastra telecom page: 39 (47) subscribing portable parts to the sip-dect system after adding a pp configuration to the omm the pp must be subscribed. The omm must first be enabled to allow subscriptions to be take place from pp handsets. This is done by pr...

  • Page 40

    Installation, administration and maintenance aastra telecom page: 40 (47) the user can enter the handsets’ number or ipei. At least one parameter has to be set. The entered number or ipei has to match exactly with a handset’s number or ipei. If number and ipei are given then a handset has to exist i...

  • Page 41

    Installation, administration and maintenance aastra telecom page: 41 (47) 4 maintenance 4.1 booter the booter may be automatically upgraded via the dhcp option 254 “update” (see chapter 3.1.4.1). 4.2 site survey measurement equipment if an sip-dect installation has to be planned, a sufficient distri...

  • Page 42

    Installation, administration and maintenance aastra telecom page: 42 (47) menu phonebook rfpi 10fff21 02 fe pp: fp: -dbm 50 57 50 rpn 02 01 00 park: 1f-10-ff-f0-21 rfp id: 02* rfp id: 02* *the id of rfp to which the pp is currently associated to. Frame error field strength rfp id in this example the...

  • Page 43

    Installation, administration and maintenance aastra telecom page: 43 (47) 4) press “ok”. 5) enter a number of seconds the phone shall ring before it will answer the call. 6) press “ok”. 7) enter a number of seconds a call shall be active. 8) press “ok”. The test will be started automatically. To sto...

  • Page 44

    Installation, administration and maintenance aastra telecom page: 44 (47) 5 appendix 5.1 communications regulation information for aastra phone 142 us fcc notices (u.S. Only) this device complies with part 15 of the fcc rules. Operation is subject to the following two conditions: (1) this device may...

  • Page 45

    Installation, administration and maintenance aastra telecom page: 45 (47) this eut has been shown to be capable of compliance for localized specific absorption rate (sar) for uncontrolled environment/general population exposure limits specified in ansi/ieee std. C95.1-1992 and had been tested in acc...

  • Page 46

    Installation, administration and maintenance aastra telecom page: 46 (47) note: this equipment has been tested and found to comply with the limits for a class b digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interferen...

  • Page 47

    Installation, administration and maintenance aastra telecom page: 47 (47) frequency (rf) energy set by the ministry of health (canada), safety code 6. These limits are part of comprehensive guidelines and established permitted levels of rf energy for the general population. These guidelines are base...