Manual is about: bdiAccess system . JTAG interface

Summary of BDI3000

  • Page 1

    Bdipro ® for xscale user manual manual version 1.00 for bdi3000 ©1993-2007 by abatron ag.

  • Page 2

    Bdipro for bdi3000 (xscale) user manual 2 © copyright 1993-2007 by abatron ag v 1.00 1 introduction ................................................................................................................................. 3 1.1 bdi3000............................................................

  • Page 3

    Bdipro for bdi3000 (xscale) user manual 3 © copyright 1993-2007 by abatron ag v 1.00 1 introduction bdipro is a powerful software package, allowing on-board programming with the bdi3000 from abatron. Bdipro eliminates the inefficient, individual chip programming, particularly for surface- mounted des...

  • Page 4

    Bdipro for bdi3000 (xscale) user manual 4 © copyright 1993-2007 by abatron ag v 1.00 1.2 functions the bdipro software provides the following functions: file load/save • save and recall user defined program sets print • print the active program set print preview • display the active program set on th...

  • Page 5

    Bdipro for bdi3000 (xscale) user manual 5 © copyright 1993-2007 by abatron ag v 1.00 2 introduction 2.1 connecting the bdi3000 to target the enclosed target cable is designed for the intel recommended 20pin jtag connector. In case where the target system has an appropriate connector, the cable can b...

  • Page 6

    Bdipro for bdi3000 (xscale) user manual 6 © copyright 1993-2007 by abatron ag v 1.00 bdi target a connector signals note: the bdi actively drives trst. It does not require any special power-up circuitry. Simply, the require- ment is that trst is weakly pulled down at the processor. It is suggested t...

  • Page 7

    Bdipro for bdi3000 (xscale) user manual 7 © copyright 1993-2007 by abatron ag v 1.00 2.2 connecting the bdi3000 to power supply the bdi3000 needs to be supplied with the enclosed power supply from abatron (5vdc). Before use, check if the mains voltage is in accordance with the input voltage printed ...

  • Page 8

    Bdipro for bdi3000 (xscale) user manual 8 © copyright 1993-2007 by abatron ag v 1.00 2.3 status led «mode» the built in led indicates the following bdi states: mode led bdi states off the bdi is ready for use, the firmware is already loaded. On the output voltage from the power supply is too low. Bli...

  • Page 9

    Bdipro for bdi3000 (xscale) user manual 9 © copyright 1993-2007 by abatron ag v 1.00 2.4 connecting the bdi3000 to host 2.4.1 serial line communication the host is connected to the bdi through the serial interface (com1...Com4). The communication cable (included) between bdi and host is a serial cab...

  • Page 10

    Bdipro for bdi3000 (xscale) user manual 10 © copyright 1993-2007 by abatron ag v 1.00 2.4.2 ethernet communication the bdi3000 has a built-in 10/100 base-t ethernet interface (see figure below). Connect an utp (unshielded twisted pair) cable to the bd3000. Contact your network administrator if you ha...

  • Page 11

    Bdipro for bdi3000 (xscale) user manual 11 © copyright 1993-2007 by abatron ag v 1.00 2.5 installation of the bdipro software on the enclosed cd you will find the bdipro software and the firmware required for the bdi. Copy all the files to a directory on your harddisk. The following files are on the ...

  • Page 12

    Bdipro for bdi3000 (xscale) user manual 12 © copyright 1993-2007 by abatron ag v 1.00 2.6.1 bdi3000 setup/update first make sure that the bdi is properly connected (see chapter 2.1 to 2.4). The bdi must be con- nected via rs232 to the windows host. To avoid data line conflicts, the bdi3000 must be di...

  • Page 13

    Bdipro for bdi3000 (xscale) user manual 13 © copyright 1993-2007 by abatron ag v 1.00 update this button is only active if there is a newer firmware version present in the execution directory of the setup software. Press this button to write the new firmware into the bdi3000 flash memory. Bdi ip addres...

  • Page 14

    Bdipro for bdi3000 (xscale) user manual 14 © copyright 1993-2007 by abatron ag v 1.00 3 specifications operating voltage limiting 5 vdc ± 0.25 v power supply current typ. 500 ma max. 1000 ma rs232 interface: baud rates 9’600,19’200, 38’400, 57’600,115’200 data bits 8 parity bits none stop bits 1 netw...

  • Page 15

    Bdipro for bdi3000 (xscale) user manual 15 © copyright 1993-2007 by abatron ag v 1.00 4 environmental notice disposal of the equipment must be carried out at a designated disposal site. 5 declaration of conformity (ce).

  • Page 16

    Bdipro for bdi3000 (xscale) user manual 16 © copyright 1993-2007 by abatron ag v 1.00 6 warranty abatron switzerland warrants the physical cd, cable and bdi3000 to be free of defects in materi- als and workmanship for a period of 3 years following the date of purchase when used under normal conditio...

  • Page 17: Appendices

    Bdipro for bdi3000 (xscale) user manual 17 © copyright 1993-2007 by abatron ag v 1.00 appendices a troubleshooting problem the firmware can not be loaded. Possible reasons • the bdi is not correctly connected with the host (see chapter 2). • a wrong communication port is selected (com 1...Com 4). • t...

  • Page 18

    Bdipro for bdi3000 (xscale) user manual 18 © copyright 1993-2007 by abatron ag v 1.00 b maintenance the bdi needs no special maintenance. Clean the housing with a mild detergent only. Solvents such as gasoline may damage it. C trademarks all trademarks are property of their respective holders..