Check that the motor data is correct. Values are predefined
on the basis of the drive size but you should verify that they
correspond to the motor.
Start with the motor type.
• Go to the edit view of a selected row by pressing
•
Scroll the view with
and
.
Motor nominal cos Φ and nominal torque are optional.
Press
(Next) to continue.
To change a value in an edit view:
• Use
and
to move the cursor left and right.
•
Use
and
to change the value.
Press
(Save) to accept the new setting, or press
(Cancel) to go back to the previous view without making
changes.
This step is optional, and requires rotating the motor. Do not
do this if it could cause any risk, or if the mechanical set-up
does not allow it.
To do the direction test, select Spin the motor and press
(Next).
Press the Hand key
Hand
on the panel to start the drive.