ABB ACS55 User Manual

Other manuals for ACS55: User Manual
Manual is about: from 0.18 to 2.2 kW

Summary of ACS55

  • Page 1

    User's guide for type acs55 ac drives from 0.18 to 2.2 kw acs55 english en dansk da deutsch de español es suomi fi français fr italiano it nederlands nl português pt Русский ru svenska sv 中文 cn 한국어 kr.

  • Page 2

    3 table of contents english . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 dansk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

  • Page 3: User'S Guide

    En 5 user's guide for type acs55 ac drives from 0.18 to 2.2 kw english en.

  • Page 4

    6 en 3afe68929300 rev b en effective: 25.02.2008 © 2008 abb oy. All rights reserved. Abb oy ac drives p.O. Box 184 fi-00381 helsinki finland telephone +358 10 22 11 fax +358 10 22 22681 internet www.Abb.Com product and service inquiries address any inquiries about the product to your local abb repre...

  • Page 5

    En 7 safety instructions read the following instructions carefully before proceeding with the installation. Warning! Dangerous voltage! Only a competent electrician may install acs55. Never work on the drive, the motor cable or the motor when main power is applied. After switching off the input powe...

  • Page 6

    8 en overview of the unit acs55 drive controls the speed of a 3-phase ac induction motor. Input terminals, page 17 power on led, page 21 fault led, page 21 control potentiometers, page 16 analogue input signal selector (voltage/current), page 18 mounting clip, pages 12 - 13 relay output terminals, p...

  • Page 7

    En 9 installation and start-up steps read safety instructions on page 7 before proceeding. Action pg. 1 check the delivery. 7 2 ensure that the installation environment is suitable for acs55. 10 3 mount the unit. 12 - 13 4 check applicability of the standard settings: motor nominal frequency is 50 h...

  • Page 8

    10 en environmental limits 1) when operating the drive in subzero temperatures, keep the input power connected. Install the drive inside an enclosure. Ensure that heat generated by the drive will be properly dissipated. Degree of protection of acs55 is ip20. Installation site storage and transportat...

  • Page 9

    En 11 dimensions f e frame a mm (in.) frame b mm (in.) frame c mm (in.) frame d mm (in.) a 53 (2.09) 72 (2.83) 74 (2.91) 74 (2.91) b 45 (1.77) 67.5 (2.66) 70 (2.76) 70 (2.76) c 128 (5.04) 128 (5.04) 159 (6.26) 159 (6.26) d 67.5 (2.66) 67.5 (2.66) - - e - - 77 (3.03) 77 (3.03) f - - 40 (1.57) 40 (1.5...

  • Page 10

    12 en mounting warning! The unit will warm up to high temperature during normal operation. Ensure sufficient cooling air flow in all conditions: - always install acs55 so that cooling fans are vertical. - leave sufficient space around frame a and b units. Frame c and d units are fan cooled, so they ...

  • Page 11

    En 13 attaching and detaching the wall mounting clip the unit can be mounted either with the wide or the narrow side against the wall. Install the mounting clip on the desired side. See instructions below for frames a and b. Detach the mounting clip of frames c and d by pulling downward and attach i...

  • Page 12

    14 en dip switches dip switches are used to adapt acs55 to the motor and the application. Warning! The dip switch is at a dangerous voltage (200 v). Turn off power and wait for 5 minutes before adjusting the switches. Keep the protective cover closed when acs55 is powered. Configuration • open the f...

  • Page 13

    En 15 additional information no. Name information 1 nom freq hz defines the motor nominal frequency (see the motor rating plate). 2 silent defines the drive switching frequency. Note: the higher the frequency the more electromagnetic noise and the shorter the allowed motor cable length to comply wit...

  • Page 14

    16 en control potentiometers the control potentiometers can be adjusted using a screwdriver. By default, all potentiometers are in their middle position. Motor i nom calculate motor i nom with the equation below or pick a value from the motor i nom selection chart below. Acs55 estimates the temperat...

  • Page 15

    En 17 connecting power supply and motor warning! Before installation ensure that the main supply is off. Note: ensure power supply is correct! Connecting 230 vac to the acs55 unit rated for 115 vac input will damage the drive! Warning! If the heat sink is not earthed properly, you can get an electri...

  • Page 16

    18 en connecting control wires internal (1) or external (2) power supply can be used for the digital inputs. Analogue control voltage is 0…10 vdc as default. (the ai jumper must be in voltage ("u") position). Control terminals use multi-strand 0.5...1.5 mm 2 wire (awg22 - awg16). 1) connected intern...

  • Page 17

    En 19 additional cabling and emc instructions follow these instructions for trouble free operation and to ensure compatibility with the european emc directive. Motor cable the motor cable must be a symmetrical three conductor cable with a concentric pe conductor or a four conductor cable with a conc...

  • Page 18

    20 en speed controlling the analogue input gives the speed (frequency) reference for acs55. The correspondence between the analogue input and the reference depends on the settings of the dip switches as shown below. Output frequency follows the reference changes as defined by the acc/dec potentiomet...

  • Page 19

    En 21 status indications and fault tracing (*) automatically reset if the autoreset is on. See dip switches on page 14 . Acs55 has two status indication leds, visible through the front cover. If the drive detects a problem, the red led will blink. After fixing the problem, reset by switching the sta...

  • Page 20

    22 en technical data * allowed for 1 minute. ** recommended values. Do not use ultra rapid or low peak fuses. Follow local rules. 230 v 115 v built-in emc, acs55-01e- 01a4-2 02a2-2 04a3-2 07a6-2 09a8-2 01a4-1 02a2-1 no emc, acs55-01n- 01a4-2 02a2-2 04a3-2 07a6-2 09a8-2 01a4-1 02a2-1 motor continuous...

  • Page 21

    En 23 maximum motor cable lengths to comply with european emc regulations, the motor cable length has to be limited as specified in the table below. The shorter the motor cable, the lower the noise emissions to the supply line and the environment. 1) switching frequency can be selected with the dip ...

  • Page 22

    24 en approvals ce the acs55 complies with the requirements of the european • low voltage directive 73/23/eec with amendments • emc directive 89/336/eec with amendments. Corresponding declarations and a list of main standards are available on request. Electromagnetic compatibility: the acs55 fulfils...

  • Page 23

    3afe68929300 rev b en, da, de, es, fi, fr, it , nl, pt, ru, sv, cn, kr effective: 25.02.2008 abb beijing drive systems co. Ltd. No. 1, block d, a-10 jiuxianqiao beilu chaoyang district beijing, p.R. China, 100015 telephone +86 10 5821 7788 fax +86 10 5821 7618 internet www.Abb.Com abb inc. Automatio...