ABB CP600 Operating Instructions Manual - page 15
Operating Instructions
14
CP600/Issue: 09.2011
SIP stands for Soft Input Panel and defines the way to edit any value on the SpiderControl MicroBrowser
under Windows CE.
Set to 0 to disable the Windows SIP and use instead of the keypad.teq and alphapad.teq in your web
project.
Set to 1 to enable the Windows SIP and automatically open the Windows SIP dialog (default).
Set to 2 to enable the Windows edit-box but without opening the SIP dialog. In the two latest cases, the
user may edit the value with a PS2 or USB keyboard. Default is 1.
Sets the SIP method:
0: Windows SIP is disabled, use keypad.teq and alphapad.teq.
1: Windows SIP is enabled, open the SIP on edit-box (*).
2: Windows edit-box is enabled, but do not open the SIP dialog.
3: Windows SIP is enabled in edit-box, like for SIP 1. And force the opening and closing of the SIP on
every Windows input dialog, like the configuration dialog.
Image memory max
Sets the maximum size in bytes used to cache image files in the MicroBrowser.
Default is 2 MB: “2097152”.
Sets the temporary directory but also the prefix of temporary files. Should be /Temp/~mb~ or ~mb~. The
latest will create temporary files with prefix ~mb~ on relative path.
Warning button: Configure the warning button in the following way:
1;time_in_sec;Label;x,y,width,height;bgndRed,bgndGreen, bgndBlue;
fgndRed,fgndGreen,fgndBlue;
Explanation:
1
: The first option allows to enable=1 or disable=0 the button.
time_in_sec
: Time in second to display the button. 0 means always on top.
Label
: Text in button.
x,y,width,height
: Allows to configure the position and the size of the button.
bgndRed,bgndGreen, bgndBlue; fgndRed,fgndGreen,fgndBlue
: Allows to define the fore-
ground and background color in decimal RGB code.
Default: 1;0;!;1,1,23,23;255,128,64;0,0,0;
Example: 1;0;Warning!;1,1,80,30;255,128,64;0,0,0;