ABB REJ603 Product Manual

Manual is about: Self-powered feeder protection, Relion 605 series

Summary of REJ603

  • Page 1

    Relion ® 605 series relion ® 605 series self-powered feeder protection rej603 product guide relion ® 605 series.

  • Page 2

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 2 abb contents 1. Description ................................................................ 3 2. Relay functions ......................................................... 3 3. Protection functions ...............................

  • Page 3

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-11-21 revision: e 3 abb 1.Description rej603 is a self-powered feeder protection relay, intended for the protection of utility substa- tions and industrial power systems, in secondary distribution networks. Rej603 i...

  • Page 4

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-011-21 revision: e 4 abb table 3. Application configurations and supported functions, continued functionality ansi iec b measurement three-phase current measurement 3i 3i ● residual current measurement in i0 ● therm...

  • Page 5

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-11-21 revision: e 5 abb 4.Application the rej603 is a protection relay aimed at selective short-circuit and earth-fault protection of feeders in secondary distribution networks and for protection of transformers in ...

  • Page 6

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-011-21 revision: e 6 abb 9.Access control to protect the relay from unauthorized access and to maintain the integrity of information, the relay is enabled with a three-level, role-based user authentication system pa...

  • Page 7

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-11-21 revision: e 7 abb 13.Technical data table 5. Dimensions relay type description value width frame 132.5 mm case 121.5 mm height frame 167.0 mm case 137.0 mm depth case 182.5 mm weight relay 2.96 kg table 6. Pow...

  • Page 8

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-011-21 revision: e 8 abb table 8. Binary input (optional functionality with external power supply) description value rated voltage 24...240 v ac, 50 and 60 hz 24...240 v dc operating range 85...110% of uaux (20.4......

  • Page 9

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-11-21 revision: e 9 abb table 12.Environmental conditions description value operating temperature range -25...+55ºc short-time service temperature range -40...+85ºc ( display viewable range : above -20 ºc up to +70 ...

  • Page 10

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-011-21 revision: e 10 abb table 15.Electromagnetic compatibility tests, continued description type test value reference fast transient disturbance tests: all ports 4 kv, 5.0 khz not applicable for low energy trip ou...

  • Page 11

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-11-21 revision: e 11 abb table 16.Insulation tests description type test value reference dielectric test test voltage test voltage for bi-stable contact 2 kv, 50 hz, 1 min 0.5 kv, 50 hz, 1 min not applicable for low...

  • Page 12

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-011-21 revision: e 12 abb table 19.Product safety description type test value lv directive 2014/35/eu standard en 60255-27 (2014) en 60255-1 (2010) table 20.Emc compliance description type test value emc directive 2...

  • Page 13

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-11-21 revision: e 13 abb 14.Protection functions table 22.Low-set phase overcurrent protection, stage i> / 51 parameter value (range) setting range of pick-up current ‘i >’ 0.1 1) ...32 x in in steps 0.001, infinite...

  • Page 14

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-011-21 revision: e 14 abb table 24.Very high-set phase overcurrent protection, stage i>>> / 50-2 parameter value (range) setting range of pick-up current ‘i >>>’ 0.2...32.0 x in in steps 0.001, infinite for ct varia...

  • Page 15

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-11-21 revision: e 15 abb table 26.High- set earth-fault protection, stage i0>> / 50n parameter value (range) setting range of pick-up current ‘i0 >>’ external earth measurement (through cbct or residual connection) ...

  • Page 16

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-011-21 revision: e 16 abb table 29.Switch-on to fault (sotf) characteristics [ specifies relay operation when relay is un-energised condition ] parameter value (range) at minimum value of pick-up current and minimum...

  • Page 17

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-11-21 revision: e 17 abb 15.Dimensions and mounting the rej603 have been supplied with mounting clamps facilitating the easy flush mounting on the panel. The panel cut-out for flush mounting: with appropriate mounti...

  • Page 18

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-011-21 revision: e 18 abb 16.Selection and ordering data the relay type and serial number label identifies the protection relay. An order number label is placed on the side of the relay. The order number consists of...

  • Page 19

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-11-21 revision: e 19 abb your ordering code: digit (#) 1-3 4-6 7 8 9 10 11 12 13 14 15 16 17 18 code figure 5. Ordering key for complete relay.

  • Page 20

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-011-21 revision: e 20 abb 17.Terminal diagram figure 6. Terminal diagram of rej603 v3.0 with external earth connection through cbct.

  • Page 21

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-11-21 revision: e 21 abb figure 7. Terminal diagram of rej603 v3.0 with external earth connection through residual connection.

  • Page 22

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-011-21 revision: e 22 abb figure 8. Terminal diagram of rej603 v3.0 with internal earth connection.

  • Page 23

    Self-powered feeder protection 1mdb07217-yn rej603 product version: 3.0 issued: 2017-11-21 revision: e 23 abb 18.References the www.Abb.Com/substationautomation portal offers you information about the distribution automation product and service range. You will find the latest relevant information on...

  • Page 24

    Contact us abb india ltd, distribution automation maneja works vadodara-390013, india phone: +91 265 6724402 fax: +91 265 6724407 www.Abb.Com/mediumvoltage www.Abb.Com/substationautomation 1m d u 07 21 7- y n e © c op yr ig ht 2 01 7 a b b . A ll rig ht s re se rv ed ..