    Abloy ® da460 swing door operator installation and commissioning manual.

  • Page 2: Approvals / Standards

    2 approvals / standards 73/23/eec (low voltage directive) 93/68/eec (low voltage directive) 89/336/eec (emc directive) statement of fi re doors by technical research centre of finland ------------------ this manual contains important safety instructions ------------------ warning - it is important f...

  • Page 3: Contents

    3 contents approvals ............................................................................................................................ 2 revision .............................................................................................................................. 4 content of del...

  • Page 4: Revision

    4 revision following pages have been revised: page revision 14 safetysensor-unit added into connections. 15-16 settings updated. 18 added a note about safety sensors. 19-26 all connections drawings updated. 28 safety sensor diagnistics added. 29 safetysensor-unit info added. As at 22.05.2015..

  • Page 5: Content of Delivery

    5 content of delivery da460 swing door operator - screws 4 pcs m8x22 da103 mounting plate - screws 6 pcs 5,5x32 da147 standard arm - screws 2 pcs 5,5x32 and 1 pcs m8x30 da148 extended arm - screws 2 pcs 5,5x32 and 1 pcs m8x30 da149 sliding arm - screws 2 pcs 5,5x50 and 1 pcs m8x30 da150 extension pi...

  • Page 6: General Information

    6 general information technical data measures • 595 (l) x 85 (h) x 107 (w) mm • weight 6,5 kg • supply voltage 90-264 vac, 47-63 hz • rated output 70 w • enclosure class ip20 temperature range • storage -30...+85°c (in dry premises) • operation: -15...+50°c (in dry premises) • the automatic swing do...

  • Page 7: Operation

    7 operation abloy ® da460 is an electromechanical swing door operator for heavy use. The door operator includes new free swing function: when using the door manually it operates lightly without motor’s resistance and the door can be left in open position when required. It can be used on both single ...

  • Page 8: Door Weight

    8 door weight 50 60 70 80 90 100 110 120 130 140 150 160 170 180 60 70 80 90 100 110 120 130 140 150 50 60 70 80 90 100 110 120 130 140 150 160 170 180 60 70 80 90 100 110 120 130 140 150 standard arm sliding arm door w eight [k g] door width [cm] door w eight [k g] door width [cm].

  • Page 9: Installation

    9 installation tools required drill set of ball ended allen wrenches # 2 phillips head screwdriver flat blade screwdrivers, 2 pcs steps of installation - preparing installation - installing the mounting plate - mounting the operator and the arm - connecting the operator to mains - commissioning - te...

  • Page 10

    10 installing the mounting plate operator is to be installed on the transom, with the main switch located towards the hinge. Use the mounting plate da103 with the door operator ensuring the installation base is level and securely fi xed to a fl at surface. Minimum requirement for wall profi le is 5 ...

  • Page 11

    11 assembly of the operator and the standard arm to the closing side hinge line mounting of the operator m8x22 and washer 70 45 min. 40 297 y 90 ° • after installation, ensure that the arm and door are properly adjusted. • mount a door stop to the door open position so that wind will not drive the d...

  • Page 12

    12 assembly of the operator and the sliding arm da149 to the closing side • after installation, ensure that the arm and door are properly adjusted. • mount a door stop to the door open position so that wind will not drive the door against the wall, resulting in damage. • tighten the holding screw. Y...

  • Page 13

    13 • after installation, ensure that the arm and door are properly adjusted. • mount a door stop to the door open position so that wind will not drive the door against the wall, resulting in damage. • tighten the holding screw. Assembly of the operator and the sliding arm da149 to the opening side m...

  • Page 14: Internal Connections

    14 - electrical connections should be made by a qualifi ed electrician. - the power plug must have an easy access. - if permanent connection is made unit must be equipped with an external switch providing all pole disconnection. - keep the mains disconnected during installation. Internal connections...

  • Page 15: Commissioning

    15 commissioning 1 check the free movement of the door. 2 turn mode switch to man. The mode switch is located in the head panel. 3 plug in the mains and turn main switch on. The main switch is located in the head panel. 4 choose the type of the arm the jumpers are located on the control board. Jumpe...

  • Page 16: Commissioning

    16 commissioning 6 check the option if the jumper is connected then operator requires n.C. Output from the fi re detector. If the jumper is disconnected then operator requires n.O. Output from the fi re detector. When jumper is connected the door can opened and closed manually. When opening impulse ...

  • Page 17: Commissioning

    17 commissioning adjust the opening speed. Minimum safe opening and closing times for door of various widths and weights are summarized in the table. Hold open times adjust fi rst hold open time for delayed impulse and then hold open time for normal impulse. Adjusting the hold open time for delayed ...

  • Page 18: A Safe Door

    18 a safe door the safety of the door operator is controlled by basic adjustments; operator force, speeds, and hold open times. • the operator force is an important adjustment. A high value affects to the safety feature and also to its sensitivity. • high speeds increases the energy transferred in t...

  • Page 19: External Connections

    19 external connections 12 3 4 5 6 789 10 11 12 +24v out gnd normal not y lock in g gnd cir cuit t in use r impulse fir e det ec to r +12v out dela ye d impulse 12 +24 vdc, 500 ma output 11 +12 vdc, 1,0 a output 10 ground 7, 8, 9 potential free relay output for lock drive 6 normal impulse 5 delayed ...

  • Page 20: External Connections

    20 external connections impulse inputs the closing contact drive (no) must be potential free. The impulse device, like a push button or motion sensor, must be installed within direct sight of the door. Maximum length of the impulse device cable is 30 meters. The total resistance of the control switc...

  • Page 21: Connection Examples

    21 connection examples safety sensor da004 and da005 red white violet blue, yellow, pink green brown 12 3 4 5 6 789 10 11 12 +24v out gnd normal not y lock ing gnd cir cuit in use r impulse fir e det ec to r +12v out dela ye d impulse 1 2 3 4 j1 j2 j3 j4.

  • Page 22: Connection Examples

    22 connection examples da061 microwave motion sensor da063 microwave motion sensor 1 2 3 4 5 6 7 8 9 10 11 12 +24 out normal not locking gnd circuit in use impulse fire detector +12v out delayed impulse gnd 1 2 3 4 5 yellow white brown green 1 2 3 4 5 6 7 8 9 10 11 12 +24 out normal not locking gnd ...

  • Page 23: Connection Examples

    23 1 2 3 4 5 6 7 8 9 10 11 12 +24 out normal not locking gnd circuit in use impulse fire detector +12v out delayed impulse gnd com n.O n.C red black blue x2 x5 1 3 2 connection examples da033 elbow switch da039 and da049 rotary switch manual = no connection autom = 2...1 auki = 2...3.

  • Page 24: Connection Examples

    24 connection examples electric locks el402, el404, el502 motor locks el490, el590 1 2 3 4 5 6 7 8 9 10 11 12 +24 out normal not locking gnd circuit in use impulse fire detector +12v out delayed impulse gnd gray blue red green white black blue red green 1 2 3 4 5 6 7 8 9 10 11 12 +24 out normal not ...

  • Page 25: Connection Examples

    25 1 2 3 4 5 6 7 8 9 10 11 12 +24 out normal not locking gnd circuit in use impulse fire detector +12v out delayed impulse gnd 1 2 3 4 5 6 7 8 9 10 11 12 +24 out normal not locking gnd circuit in use impulse fire detector +12v out delayed impulse gnd impulse device active door passive door connectio...

  • Page 26: Connection Examples

    26 connection examples fire door system operation: when detector reacts, it’s relay switches on. Then the gnd (-) is disconnected from the operator’s control unit (connector 2). The operator doesn’t open the door from impulse but it have to be opened manually. The operator closes the door after manu...

  • Page 27

    27 self diagnostics (control unit) the means of diagnostic features is to • detect malfunctions • try to take care of safety during malfunction • get the operator to recover from the defected state in case the result of the diagnostics shows unrecoverable malfunctions, the door operator is considere...

  • Page 28: Maintenance

    28 maintenance requirements for trouble-free use of the operator installation, commissioning and maintenance is made by trained and qualifi ed technician. Door leaf is moving sensitively and locking works well. Regular annual services are made: • under 100 openings per day; service once a year • 100...

  • Page 29: Da460 Spare Parts

    29 da460 spare parts head panel 810174 vaihtopaketti 809854 position sensor 809863 control unit 809877 mode switch 806914 rear damper 809820 side damper 803520 transformer 810057 main switch 807437 da147 da148 da149 cover aluminium 410358 cover white 410357 safetysensor-unit 5742362.

  • Page 30

    30

  • Page 31

    31.

  • Page 32

    Nimik e: 9312568 päiväys: 05/2015 mjp / 25.5.2015 / indesign this product contains materials, such as electronics, which require specialist recycling techniques. When the product is taken out of use, disassemble it and sort and recycle the different materials as per valid recycling instructions. We ...