Accton Technology 3008A Quick Installation Manual - Mounting The Hub
CheetahSwitch Workgroup-3008A/3016A
2
The following figure shows the components of these switches:
Mounting the Hub
This switch can be placed directly on your desktop, or mounted in a rack
(ES3016A).
Before you start installing the switch, make sure you can provide the right
operating environment, including power requirements, sufficient physical space,
and proximity to other network devices that are to be connected. Verify the
following installation requirements:
Power requirements: 110 to 230 VAC (± 10%) at 47 to 63 Hz (± 3Hz). The
switch's power supply automatically adjusts to the input voltage level.
The switch should be located in a cool dry place, with at least 10 cm. (4 in.) of
space at the front and back for ventilation.
Place the switch out of direct sunlight, and away from heat sources or areas
with a high amount of electromagnetic interference.
If you intend to mount the switch in a rack (ES3016A), make sure you have all
the necessary mounting screws, brackets, bolts and nuts, and the right tools.
Check if network cables and connectors needed for installation are available.
Stacking Switches on a Flat Surface
The CheetahSwitch can be stacked
anywhere there is enough flat space, such
as on a table or desktop.
1. Stick the self-adhesive rubber foot pads
(that come with this package) on each of the 4
concave spaces located on the bottom of the first switch.
2. Place the first switch on a firm flat surface where you want to install the stack.
3. Repeat step 1 for each switch before stacking them. The rubber foot pads
cushion the switch against shock/vibrations and provide space between each
switch for ventilation.