5. Apply a full container (or a load representing the weight of a full container) on the platform.
Wait 5 seconds for the load to stabilize, then press
. This completes the training process,
and the SET TANK indicator will turn off.
6. From this point forward, the Alternate Numeric Display will show the percent of material
remaining in the container from 0% to 100%.
NOTE: The 100% weight must be larger than the 0% weight by at least 200g. If not, “Err” will
show on the Alternate Numeric Display. To clear the error, retrain as above using a 100% weight
that is at least 200g larger than the 0% weight. During training, the ZERO key may be used to
assist in setting the 0% and 100% values. This will have no effect on the training, as the Tank
Capacity Mode relies on absolute, not relative, weights.
Turning Tank Capacity Mode Off
Perform the following steps to turn the Tank Capacity Mode Off:
1. While holding
down, press
. The SET TANK indicator will turn on, and ON will flash
on the display. This indicates that the Tank Capacity Mode is currently on.
2. Turn the Tank Capacity Mode off by pressing
. The display will flash OFF, and the
Alternate Numeric Display will turn off.
3. Press
to return to normal operation.
Turning the Tank Capacity Mode On without Re-training
The Tank Capacity Mode can be turned back on without retraining. The DS-220 will remember
the previous 0% and 100% set points until the unit is re-trained as above. To turn the Tank
Capacity Mode on without re-training, perform the following steps:
1. While holding
down, press
. The SET TANK indicator will turn on, and OFF will flash
on the display. This indicates that the Tank Capacity Mode is currently off.
2. Turn the Tank Capacity Mode on by pressing
. The display will flash ON, and the
Alternate Numeric Display and Percent Indicator will turn on.
3. Press