Refrigerant:
Australia only
R22
Euro production
R407C
Charge:
650 grms.
Air volume (max) Air Handler:
110 l/s
Compressor:
Sanyo KR6102
Resistance run wdg.:
2.8
Ω
Resistance start wdg.:
4.3
Ω
Capacitor:
20 mfd. 440 vac
Fan (Air handler):
Resistance run wdg.:
165
Ω
Resistance aux wdg.:
265
Ω
Capacitor:
1.5 mfd. 440 vac
Fan (Condenser set):
Resistance run wdg.:
168
Ω
Resistance aux wdg.:
150
Ω
Capacitor:
2.5 mfd. 440 vac
Heating element:
1500W
(Pt. No. 4002024)
Refer fitting instructions included
Condenser set:
Height
-
235 mm Above floor
Width
-
460 mm
Depth
-
440 mm
Weight
-
30 kg
Air Handler:
Height
-
220 mm
Width
-
385 mm
Depth
-
230 mm
Weight
-
4 kg
Minimum cupboard dimensions:
320 high x 525 wide x 300 deep
Cooling output:
2.2 KW
Heating output:
1.5 KW
Maximum current (cooling):
4.0 amps
Maximum current (heating):
6.5 amps
Maximum locked rotor current:
19 amps
UNIT SPECIFICATIONS
8
OPERATING INSTRUCTIONS
This appliance is not intended for use by young children or infirm persons without supervision. Young
children should be supervised to ensure that they do not play with this appliance.
This airconditioner may be used in cooling mode with outside temperatures from 18ºC to 48ºC, and inside
temperatures from 18ºC to 30ºC. In heating mode, the airconditioner may be used with outside and inside
temperatures up to 30ºC.
COOLING:
(ref fig.16)
NB.
The unit will not run on cooling if the inside temp. is much below 18°C.
1. Turn fan speed selector to
(Hi Speed Cooling)
2. Turn mode selector to
(Cooling)
3. Adjust the thermostat counter clockwise until the condenser set is heard to start.
4. Gradually over time, adjust the thermostat until comfortable conditions are maintained.
AVOID RESTARTING THE COMPRESSOR WITHIN 3 MINUTES OF TURNING OFF
HEATING:
(ref fig.16)
NB.
The unit will not heat if inside temp. is much above 28°C.
1. Turn fan speed selector to
(Heating Speed)
2. Turn mode selector to
(Heating)
3. Adjust the thermostat to max. clockwise position.
There will be approximately 30 seconds delay before heating is apparent.