Airlogic ABM-200 Application Note - page 2
Bluetooth™ Module Application Note
Copyright © 2004 AirLogic Co., Ltd.
All specification are preliminary and AirLogic reserves the right to change these without notice.
http://www.airlogic.co.kr
6. Electrical Characteristics
Absolute Maximum Ratings
Parameter Min Max
Unit
Storage Temperature
-40 +85
°C
Supply Voltage(VDD)
2.7
3.6
DCV
Supply Voltage(PVCC)
3.0
3.0
DCV
Other Pin Voltage
V
ss
-0.4 V
DD
+0.4 DCV
Recommended Operating Conditions
Parameter Min Max
Unit
Temperature -20
+70
°C
Supply Voltage for UART
3.0
3.6
DCV
Supply Voltage USB
3.1
3.6
DCV
7. RF Specification
Transmitter Performance
Parameter
Condition
Min
Typ
Max
Unit
Output Power
Normal/extreme test
-
16
20
dBm
Power Density
Normal/extreme test
-
-
20
dBm
Power Control
Normal/extreme test
2dB ≤ Step size ≤ 8dB
Frequency Range
Normal/extreme test
2400
-
2483.5
MHz
20dB Bandwidth
Normal/extreme test
-
850
1000
KHz
±2MHz -
-
-20
dBm
±3MHz -
-
-40
dBm
Adjacent channel power
±4MHz -
-
-40
dBm
∆F1
avg
140 - 175
KHz
∆F2
max
115 - - KHz
Modulation Characteristics
∆F2
avg
/
∆F1
avg
- - 80
%
Initial Carrier Frequency Tolerance
-75
-
75
KHz
One slot packet(DH1)
-25
-
25
KHz
Three slot packet(DH3)
-40
-
40
KHz
Carrier Frequency Drift
five slot packet(DH5)
-40
-
40
KHz
Transceiver Performance
Parameter
Condition
Min
Typ
Max
Unit
30MHz-1GHz -
-
-36
dBm
1GHz-12.75GHz -
-
-30
dBm
1.8GHz-5.3GHz -
-
-47
dBm
Out-of-Band Spurious Emissions
5.1GHz-5.3GHz -
-
-47
dBm
Receiver Performance
Parameter
Condition
Min
Typ
Max
Unit
Sensitivity level
Single slot packets
-70
-83
-
dBm
Sensitivity level
Multi slot packets
-70
-
-
dBm
C/I
co-channel
- - 11
dB
C/I
1MHz (Adjacent channel selectivity)
- - 0 dB
C/I
2MHz (2nd Adjacent channel selectivity)
- - -30
dB
C/I performance
C/I
≥3MHz (3rd Adjacent channel selectivity)
- - -40
dB
30MHz-2000MHz -10
-
-
dBm
2000MHz-2400MHz -27
-
-
dBm
2500MHz-3000MHz -27
-
-
dBm
Blocking performance
3000MHz-12.75MHz -10
-
-
dBm
Intermodulation
Performance
n=5 -39
-
-
dBm
Maximun Input Level
-20 -10 - dBm