    Airpax dimensions, inc. U.P.S. Unintertuptable power supply (external battery type) owners manual for models: adi-24/2400n ups adi-24/4800n ups including option "d" form 121585 121585b owner's manual february 2007 airpax dimensions, inc. 4467 white bear parkway (651) 653-7000 st. Paul, mn 55110-7626...

  • Page 2

    Owners manual for airpax dimensions inverters model adi-24/2400n ups model adi-24/4800n ups including options "d" table of contents page 1. General . . . . . . . . . . . 2 2. Description . . . . . . . . 2 3. Installation . . . . . . . . 3 4. Start up/operation. . . 5 5. Troubleshooting. . . . . 5 6....

  • Page 3

    Charging of the internal input capacitor. 3.05.2 use stranded copper wire between the battery and inverter as indicated. A line fuse must be installed between the battery and the inverter. U.L. Requires that the fuse be within 18 inches of the battery. Dc input wire lengths (maximum) and fusing guid...

  • Page 4

    Termainal of the switch. The input terminal of the switch should be connected to 5 amp. Fused +24 vdc. The cable clamp strain relief should be used to secure the field wires. 3.06.3 the switch should be mounted at a convenient location in a listed outlet box with approved strain relief. 3.06.4 note:...

  • Page 5

    Page 5 4. Start up / operation 4.01the battery charger will operate anytime that there is external ac power and the battery is not 100% charged. The status lights will indicate that there is external power and the battery’s condition. 4.02 there are two switches on the right side that should be set....

  • Page 6

    A) the low input voltage light indicates a low battery condition. Switch the u.P.S. “off” for 5 seconds, then “on” again. The light coming on again indicates a fault in the battery wiring, battery capacity and voltage or the line fuse. B) the overload light indicates an output wiring short circuit o...

  • Page 7

    A.C a.C. Input output neg a.C. A.C. Input battery remote output transfer charger pos a.C. Input earth ground earth ground warning: connecting the battery with the wrong polarity to the u.P.S will cause damage that is not covered under the war- ranty. Fig. 1 installation wiring fuse fuse +24 from bat...

  • Page 8

    Limited warranty terms & conditions shipping terms f.O.B. St. Paul minnesota - usa loss or damage loss or damage in transit is the responsibility of the carrier. Any claim should be filed with the delivering transport company. Invoice, bill of lading and delivery receipt with damage noted therein mu...