Airpax Dimensions ADI-36/3200D Owner's Manual - page 2
OWNERS MANUAL
FOR AIRPAX DIMENSIONS
INVERTERS
ADI-36/3200D
ADI-36/5800D
ADI-36/8000D
Including Option: T
Table of Contents
Page
1. General . . . . . . . . . .
2
2. Description . . . . . . .
2
3. Installation . . . . . . .
2
4. Start Up/Operation . .
4
5. Troubleshooting. . . . .
5
6. Installation Figure 1. .
6
7. Warranty . . . . . . . . . 7
1. GENERAL
1.01 Dimensions inverters have been designed
and manufactured for many user applications and
long life. They utilize patented construction
methods and high technology electronic parts
and circuitry.
1.02
CAUTION: Inverters produce hazard-
ous voltages, to avoid risk of harm or fire the
unit must be properly installed. There are no user
serviceable parts inside, do not remove the
cover.
CAUTION: The inverter should not be mounted
in a location that may be exposed to rain or
spray.
CAUTION: The inverter should not be installed
in a zero clearance enclosure.
CAUTION: Damage to the inverter will occur if
correct polarity is not observed when installing
the DC input cables.
CAUTION: Damage to the inverter will occur if an
external AC power source is applied to the
inverter’s AC output or it’s hardwire output.
CAUTION: The inverter contains a circuit breaker
and capacitor that may produce a spark. Do not
mount in a confined battery or gas compart-
ment.
CAUTION: Working in the vicinity of lead-acid
batteries is dangerous. Batteries generate explo-
sive gases during operation. There is a risk of acid
exposure. There is also a risk of high current
discharge from shorting the battery that can
cause fire and explosion.
CAUTION: Be sure both the inverter and, if
used, the external AC input circuit breaker or
fuse are turned "OFF" during installation.
2. DESCRIPTION
2.01 The inverter converts 36 VDC to 120/240
VAC, 60 HZ, having a quasi-sine wave form.
2.02 The inverter has internal protection
against output short circuit, output overload and
high temperature conditions. Also, there is a
thermally controlled cooling fan.
2.03 The inverter is designed to operate almost
any 120/240 VAC, 60 HZ, single phase equip-
ment within its power ratings, unless specifically
designed for a pure sine waveform.
Inverter Rating
Inverter Input Output
Model (VDC) (ADC) (VAC,RMS) (Watts)
36/3200 37.8 Up to 110 120 3200
36/5800 37.8 Up to 200 120 5800
36/8000 37.8 Up to 125 120 8000
3. INSTALLATION
3.01 The following instructions should be
Page 2