AirPro AP500 Operation User's Manual - page 19
Chapter 3: Operation
13
Term
Definition
Feature
Display Sleep
Time
Display Sleep can be used to prolong battery life on the instrument. If
a period of inactivity is detected from the keypad, the display is turned
off. The display can be reactivated by tapping any key on the probe
keypad.
Basic, Advanced
and Professional
Auto Shut Off
Time
Auto Shut off can be used to prolong battery life. If this option is
enabled, the instrument will shut off automatically when it has
detected a period of inactivity. The handle will not shut off if it is
paired with AirPro Mobile or if it is logging or if there is activity on the
probe keypad.
Basic, Advanced
and Professional
Calibration
Certificate
The Calibration Certificate feature allows you to request an electronic
copy of the probe’s calibration certificate. The most recent certificate
will be sent to the email address you set up in your User Profile.
Professional
Sample
Each time you start logging, a sample is taken from all connected
probes. A sample consists of measurements stored at the same time.
The values stored will be the averages over the sampling interval.
Advanced and
Professional
Sampling Interval
Average measurements will be displayed and logged at the end of
each Sampling Interval. Set the Sampling Interval to exceed the time
constant. For example, if the sampling interval is set to 10 seconds,
each sample will be the average over the previous 10 seconds.
Advanced and
Professional
Test ID
Each sample is associated with a Test ID. A Test ID may include
multiple samples as long as each sample has a similar test
configuration including offsets, units of measure, probe hardware, etc.
AirPro Mobile creates a table of summary statistics (minimum,
maximum, average) for data files saved to the Smartphone.
Advanced and
Professional
Manual Save
The Manual Save option lets you set a Sampling Interval. Average
measurements will be displayed and logged at the end of each
Sampling interval. Set the Sampling interval to exceed the time
constant.
Data is logged to AirPro Mobile.
Advanced and
Professional
View Before
Saving
Manual Save allows the option to View Before Saving. By default this
feature is disabled so AirPro Mobile automatically saves every
sample you initiate. If you enable this feature, AirPro Mobile will
display the measurement at the end of the Sampling interval and give
you the option to save it or discard it.
Advanced and
Professional
Continuous Save
Continuous Save lets you set a Sampling Interval. Average
measurements will be logged at the end of each Sampling interval.
Set the Sampling interval to exceed the time constant.
Advanced and
Professional
Test Length
Continuous Save lets you set the Test Length. Samples will be
logged automatically until the Test Length has ended.
Advanced and
Professional
Save Data To
By default data is logged to AirPro Mobile (your smartphone).
Available with a Professional user license is the option to Save Data
to a memory card on your probe. One Test ID at a time can be saved
to a memory card. It can be retrieved from the card using a card
reader or by using the download feature described in Probe Settings.
Professional