Airrex ADH-100 User Manual

Manual is about: DEHUMIDIFIER

Summary of ADH-100

  • Page 1

    Airrex dehumidifier adh-1000 user’s manual ▶ thank you for purchasing an airrex dehumidifier. Before operation please read this user’s manual carefully. ▶ keep this manual readily available. ▶ it is essential that you read the ‘notes on safety’ carefully before use and follow them at all times. ▶ th...

  • Page 2

    Table of contents ■ safety instructions ■ description ·front view ·back view ·control panel ■ operation ·running & stop ■ cleaning and maintenance ■ trouble shooting ■ ■ specifications ■ warranty 3 5 5 5 6 7 7 8 9 10 11 12 13 13 2 14 manual pumping ·continuous running ·error and warning indicators ·...

  • Page 3

    The following symbols are for your guidance: keep this manual in a visible location near the dehumidifier for easy reference. Safety instructions the following instructions are for ensuring the user’s safety and to prevent any physical injury or material damage. Please read carefully and follow all ...

  • Page 4

    Safety notice general advice before use ·ensure the safety of the location in which dehumidifier is to be used. ·ensure the floor or ground is smooth and sound. ·ensure you allow at least 1m air space all around the dehumidifier. ·when in position lock the casters to prevent rolling. ·never use the ...

  • Page 5

    5 description front view back view air inlet ambient air intake. Caster (front lockable) caster (rear 10'') back handle evaporator filter condenser grille condenser air outlet power cord digital controller condensed water outlet during dehumidifying pump button.

  • Page 6

    6 ① power : use to power on / off. ② : raises or lowers setting humidity and sleep (off) time. ③ fan intensity : controls fan speed. High,medium,low ('f3' 'f2' 'f1') ④ quiet operation : set fan speed slower than 'low'(fl), the led is on. ⑤ off timer : to set the length of time, once turned on, that ...

  • Page 7

    7 operation 1. Start by pressing the ‘power’ button. ·dehumidifier will start up automatically. ·to stop the unit, press the ‘power’ button once again. 2. To change fan speed, press the ‘fan’ button. ( 'f3' : high, 'f2' : medium, 'f1' : low ) running & stop.

  • Page 8

    8 setting humidity % current humidity setting humidity % % setting humidity % 1. When power is on, the setting humidity is displayed. Default of setting humidity is 60%. 2. When you push either ▼ or ▲ button, the setting humidity is changed. 3. The display showing the setting humidity will blink 3 t...

  • Page 9

    9 1. When dehumidifier is operating, press the ‘off timer’ button and set the length of time you want by pressing ▲ or ▼. Each time you press the button you will increase the ‘time to off’ period by 30mins. Up to 10 hours, and 1 hour thereafter up to 24 hours. The display will show .5 for 30min and ...

  • Page 10

    10 current humidity current humidity current humidity current humidity setting humidity current humidity the machine’s safety devices will automatically signal any problems via the display window on the control panel. The information below shows how to read these signals. 1. Water full- display show...

  • Page 11

    Operation continuous running humidity. Humidity. % % 5sec 1. If you press the "off timer" button for 5 seconds, it operates continuously 2. Setting value is changed to circle type. 3. To cancel this mode press "off timer" button for 5 second. 10 11 5sec.

  • Page 12

    Cleaning and maintenance cleaning the air filters maintenance 1. To remove filters, open the front case ①, and pull towards you. ② 2. Clean the filters with water or compressed air. 3. Clean heat exchanger unit with a vacuum cleaner or compressed air. 1. Turn “off” at control panel, remove plug from...

  • Page 13

    12 trouble shooting troubl check remedy ● power plug correctly connected ● connect plug correctly ● power button “off” ● press power button to “on” ● blown fuse in electric panel ● replace fuse (5a) ● fuse blown ● exchange fuse in board (1a) ● breaker on switch board ● check load capacity and reset ...

  • Page 14

    Specifications model adh-1000 maximum 120 power supply 230v~. 50hz. 1ph dimension(wxdxh) 506 x 552 x 995 weight 60 air flow 1,080 area 1,000 power consumption 2.21 current consumption 9.73 refrigerant(r-410a) 1,000 air filter vinyl chloride mesh catridge safety device ▶ high pressure switch ▶ low pr...

  • Page 15

    15.

  • Page 16

    16.

  • Page 17

    17.

  • Page 18

    18.

  • Page 19

    Warranty (applicable to first retail purchaser only) airrex dehumidifier give more reliable performance, comfort and durability the more they are used. They are built under a strict quality assurance regime which includes inspection both during and after production and exhaustive reliability testing...

  • Page 20

    ● designs and specifications of products are subject to change without prior notice for the improvement of products. Hephzibah co.,ltd. 1385-15 juan-dong, nam-gu, incheon, korea tel : +82-32-509-5834 fax : +82-32-502-5519 e-mail : airrex@hdtek.Com website : www.Airrex.Co.Kr.