The machine’s safety devices will automatically signal any problems via the display window on the control panel.
The information below shows how to read these signals.
1. WATER FULL- Display shows “FU”
When the water container is full, “FU” is displayed
and the LED “Water Full” light will be on.
2. HIGH PRESSURE
‘E1’ is displayed and the ‘Error’ LED will be on
when the pressure of the compressor is too high
and
the high pressure switch is open.
3. LOW PRESSURE
‘E2’ is displayed and the ‘Error’ LED will be on
when the pressure of the compressor is too low.
4. DEFROST SENSOR PROBLEM
If the thermistor for defrost is short circuited
or cut, 'E3' is displayed and the 'Error' LED
will be on.
5. HUMIDITY SENSOR PROBLEM
If the Humidity Sensor is short circuited or cut, ‘Hu’ is
displayed and the ‘Error’ LED will be on.