Airrex HSC-18PLUS Operating Instructions And Parts Manual - Maintenance
TROUBLE CHECK
REMEDY
●
Power plug incorrectly connected
●
Connect plug correctly
●
POWER button “OFF”
●
Press POWER button to “ON”
●
Fuse (supply) blown
●
Replace fuse
●
Breaker on switch board
●
Check load capacity and reset
tripped
●
Ambient temp. too high
●
Use only below 113℉,45℃
(over 113℉,45℃)
●
Filter blocked with dust
●
Clean Filter
●
Dust in heat exchanger
●
Clean heat exchanger
●
Obstacle against inlet side
●
Remove and allow 20" (51 cm) clearance
●
Ambient temp. too high
●
Use only below 113℉,45℃
(over 113℉,45℃)
1. To remove filters, slide up a little ① and pull
towards you ②.
2. Clean the filters with water or compressed air.
3. Clean evaporator and condenser units with a
vacuum cleaner or compressed air.
1. After cleaning, completely dry
the inside of the unit by
operating on ‘Fan Mode’
for 3 to 4 hours.
2. Turn “OFF” at control panel,
remove plug from socket. Coil
and store cable neatly.
3. Keep machine suitably covered to
prevent damage by damp,
humidity and dust.
MAINTENANCE
CLEANING THE AIR FILTERS
MAINTENANCE
Operating Instruction & Parts Manual
NOT
WORKING
POOR
COOLING
TROUBLESHOOTING CHART
R
R
R
R
R
R
R
R
rev0