7. Press the stop button when you have finished using the appliance, then strip the appliance and
thoroughly clean both the opening and all other components.
6 REGULAR CLEANING
6.1 GENERALITIES
The appliance clean must be cleaned at least once a day or if necessary more than once.
Scrupulously clean all the various components of the HM-12/HM-22/HM-22A whether they
come in direct contact with the food product or not.
Never clean the HM-12/HM-22/HM-22A with a pressurized water-jet, industrial cleaner, and
brushes or any other type of cleaning utensil that could damage the surface of the appliance.
Before cleaning you must remove the electricity supply plug isolating the appliance
from the main power circuit.
6.2 PROCEDURE TO FOLLOW FOR CLEANING THE APPLIANCE
- remove the pestle and food tray;
- unscrew the lock nut: No.1 and remove the disk: No.2, blade No. 3, screw feeder No.4, unscrew in the
direction indicated by the arrow No.5.
- unscrew the knob and remove the mincer No.6, always in the direction indicated by the arrow.
Now all the components can be washed( see fig 6 )using warm water ( 50 ℃) and a neutral detergent.
To clean the main structure use a damp cloth remember to frequently rinse
The grater roller mounted on the HM-12/HM-22/HM-22M Should be brushed. Carefully clean the
punched holes. Make sure all the components are completely dry before remounting them.
N.B. to remount the HM-12/HM-22/HM-22A follows the above diagrams:
1) Mount the mincer block and block it in position using the knob; the pin on the knob must be inserted
into the opening No.7;
2) Insert the screw feeders No.4 into the mincer block make sure it is positioned correctly;
3) Mount the blade No.3 onto the square pin on the screw feeder and then mount the disk No.2
maintaining the original coupling configuration;
4) Once all the components have been mounted secure by screwing the lock nut in place.
FIG 6-Removing components
7 6 4 2
5
1
3