WARNING
• Stay with the machine during the descalling process and clean the
machine.
• When descaling, always follow the instructions of the descaling agent used.
• When using a descaling agent it is advisable to wear protective gloves
and safety goggles.
• Allow the machine to operate with clean water at least twice to rince
the solution from the system.
• After descaling, wash your hands thoroughly.
• If the machine is not being used it is advisable to disconnect the
appliance.
8. DESCALING
Switch off the cold water heater and wait until the water in the water
heater has become cold so that the blending tray can be easily removed.
As soon as the B100 has cooled down, remove the lid (fig. 7A) from the
reservoir and lift the blender (fig. 7B) from the water heater. The whole
boiler will now be visible. Tilt the B100 (fig. 8) to empty the water together
with possible loose scaling. For removing the rest of the scaling use
“ANIMO” descaling agent. Prepare an acid solution of ± 3 tablespoons of
powder per one litre ± 60-70°C.
The blender cannot be cleaned with a
descaling agent, as it is not acid resistant
.
Pour the solution into the machine to just below the syphon and leave for
a while. Place an empty slide-in filter (fig. 1C) in position and an empty jug
below it. Pour one jug of water into the water heater so that the solution is
drained from the water heater through the syphon. Then the water heater
can be emptied. Put the blender into the water heater with the arrow
pointing in the direction of the filter. Replace the blender in the water heater
and fill up the B100 with water as described in section 5 (PREPARATIONS
BEFORE USE). Allow the machine to operate with clean water at least
twice to rince the solution from the system.
9. BREAKDOWN ANALYSIS
The B100 does not heat up the water. The water remains cold while the
switch for activating the water is on.
9.1 CAUSE AND SOLUTION
- The dry heating protection device is switched off.
The B100 is fitted with a dry heating protection device that can be
reached externally at the back next to the electrical cable (fig. 9).
Remove the protective cover and press the button. The element will then
be switched on again.
- If a breakdown is not caused by the dry heating protection device,
consult your dealer.