IMPORTANT!
The 3 core main cable (fig. 2) has the following wiring code:
•
Green/yellow - Earth (E)
•
Blue – Neutral
(N)
•
Brown – Phase
(L)
4. CoNTRoLs
Refill indicator
(fig. 3A);
Model HA
: the yellow indicator light will light up if the water boiler
needs to be refilled. The heating element will turn off. The indicator light turns off when the
water boiler has filled up sufficiently.
Model VA
: the yellow indicator light will light up when the water boiler is automatically refilling.
The heating element will turn off. The indicator light turns off when the water boiler has been
filled up sufficiently.
Temperature ok indicator light
(fig. 3B); The green indicator light lights up when the
waterboiler has reached the correct temperature. The control light turns off when the
water temperature is too low.
Temperature adjuster water boiler
(fig. 3C); With this adjuster the water boiler temperature
can be increased/reduced, using a small screwdriver.
• In high altitude areas (> 2000 meters.) the water will boil sooner because of lower
atmospheric pressure. Adjust the temperature of the water boiler, so it will not boil.
• The manufacturer is unable to accept any liability for the consequences of altered
settings.
On delivery the temperature of the water boiler is set at approx. 90°C.
With the adjustment point (fig. 3C) the temperature of the water boiler can be increased / reduced
within a range of 84°C – 98°C. Use a small screw driver for this.
To reduce the temperature, turn left. To increase the temperature, turn right.