Anritsu MG3710A Configuration Manual

Other manuals for MG3710A: Operation Manual
Manual is about: Vector & Analog Signal Generator

Summary of MG3710A

  • Page 1

    Configuration guide vector signal generator mg3710a configuration guide.

  • Page 2

    2 configuration guide l mg3710a mg3710a-062/162 2ndrf 100 khz to 2.7 ghz mg3710a-064/164 2ndrf 100 khz to 4 ghz mg3710a-066/166 2ndrf 100 khz to 6 ghz frequency range for 2ndrf ∗ select one of following mg3710a-071/171 high power extension for 2ndrf mg3710a-072/172 low power extension for 2ndrf mg37...

  • Page 3

    Configuration guide l mg3710a 3 mg3710a-062/162 2ndrf 100 khz to 2.7 ghz mg3710a-064/164 2ndrf 100 khz to 4 ghz mg3710a-066/166 2ndrf 100 khz to 6 ghz frequency range for 2ndrf ∗ select one of following mg3710a-071/171 high power extension for 2ndrf mg3710a-072/172 low power extension for 2ndrf mg37...

  • Page 4

    4 configuration guide l mg3710a this document explains how to order the new mg3710a and mg3710a retrofit options and software. Follow the steps below to select your mg3710a configuration. Functions marked standard are built-in at factory shipment. Options and software can be added as necessary. Two ...

  • Page 5

    Configuration guide l mg3710a 5 step. 4 select the signal output level setting range expansion and the reverse input power protection. Name option no. Additional information high power extension for 1strf mg3710a-041 extends signal output setting range upper limit (standard +17 dbm) opt. 041/141 ins...

  • Page 6

    6 configuration guide l mg3710a step. 5 select the baseband vector signal generator arb memory size option. The selected memory is enabled and others are disabled. Name option no. Additional information arb memory 64 msample for 1strf standard standard baseband generator for 160 mhz sampling rate an...

  • Page 7

    Configuration guide l mg3710a 7 step. 7 choose the analog input/output options. Name option no. Additional information analog iq input/output mg3710a-018 installs analog i/q input and output connectors on rear panel of main frame but only supports sg1 side (1strf side) step. 8 choose the external in...

  • Page 8

    8 configuration guide l mg3710a step. 12 choose waveform pattern software. The waveform pattern software function sets the selected waveform using previously set parameters. The waveform patterns are installed in the mg3710a and the signal is output by selecting them. When outputting a waveform patt...

  • Page 9

    Configuration guide l mg3710a 9 step. 13 choose iqproducer software license. Iqproducer is pc application software for generating waveform patterns. The parameters are set using iqproducer and the waveform pattern is created to output the signal by selection at the mg3710a. This one software applica...

  • Page 10: Retrofit to Current Mg3710A

    10 configuration guide l mg3710a hardware option retrofits the following hardware options can be retrofitted. The mg3710a must be returned to the anritsu plant for hardware retrofitting. Name option no. Additional information reference steps options for both 1strf and 2ndrf rubidium reference oscill...

  • Page 11

    Configuration guide l mg3710a 11 software option retrofits the following software options can be retrofitted. The mg3710a does not require return to the anritsu plant for software retrofitting. Name option no. Additional information reference steps waveform patterns dfs radar pattern mx370073a 12 df...

  • Page 12: Options Configuration Guide

    12 configuration guide l mg3710a options configuration guide the following table shows the recommended option combinations. Type opt. No retrofit name 032 034 036 018 041 042 043 045 046 048 049 062 064 066 071 072 073 075 076 078 079 001 002 011 017 021 029 313 1strf mg3710a-032 1strf 100 khz to 2....

  • Page 13

    Configuration guide l mg3710a 13 the following table shows the recommended option combinations. Type opt. No retrofit name 032 034 036 018 041 042 043 045 046 048 049 062 064 066 071 072 073 075 076 078 079 001 002 011 017 021 029 313 1strf mg3710a-032 1strf 100 khz to 2.7 ghz ∗ 1 ∗ 1 1strf mg3710a-...

  • Page 14: Ordering Information

    14 configuration guide l mg3710a ordering information please specify the model/order number, name and quantity when ordering. The names listed in the chart below are order names. The actual name of the item may differ from the order name. Model/order no. Name remarks mg3710a - main frame - vector si...

  • Page 15

    Configuration guide l mg3710a 15 model/order no. Name remarks mg3710a-es210 mg3710a-es310 mg3710a-es510 - maintenance service - 2 years extended warranty service 3 years extended warranty service 5 years extended warranty service mx370073a mx370075a mx370084a - softwares - (waveform pattern) dfs rad...

  • Page 16

    • united states anritsu company 1155 east collins blvd., suite 100, richardson, tx 75081, u.S.A. Toll free: 1-800-267-4878 phone: +1-972-644-1777 fax: +1-972-671-1877 • canada anritsu electronics ltd. 700 silver seven road, suite 120, kanata, ontario k2v 1c3, canada phone: +1-613-591-2003 fax: +1-61...