Step 3:
Connect the machine to suitable rated power supply.
To determine the power
requirement for the machine refer to the label on the back of the machine.
Always connect the machine to a protected circuit and ensure it is properly
grounded to avoid risk of electrocution.
Step 4:
Turn on the machine and allow it to heat up. Heat up takes approximatly 7.5 mintues.
Once the machine has reached operating temperature, the LED inidcator located in back
panel will turn solid green. Now the machine is ready for operation.
Step 5:
To start making fog, press and hold the push button on handle bar, release to stop.
Step 6:
To adjust output volume, rotate the knob located in back panel. Turn
counter-clockwise to increase, clockwise to decrease.
Step 7:
To turn off the machine, flip the power switch to OFF position. Remove aerosol and
power cord.
Off Power Operation
FT-50 can be operating off mains power once it has reached working temperature. The
amount of smoke can be produced depends on its temperature cycle when it is
disconnected. With a complete heating cycle the machine can still generate smoke up to 45
minutes after disconnection.
The quality of fog must be carefully observed while operating off mains power. When smoke
has become thin and blue indicates the temperature is getting low. Reconnect machine to
mains power for heating process, once it reached working temperature it can be operate off
power again.