Auber SYL-2342 Instruction Manual

Other manuals for SYL-2342: Instruction Manual

Summary of SYL-2342

  • Page 1

    Syl-2342, syl-2352 pid temperature controller instruction manual version 4.4 auber instruments www.Auberins.Com 2011.02 p1/8 instruction manual 1. Specification input type thermocouple(tc): k, e, s, n, j, t, b, wre5/26 rtd(resistance temperature detector): pt100, cu50 dc voltage: 0~5v, 1~5v, 0~1v, -...

  • Page 2

    Auber instruments www.Auberins.Com 2011.02 p2/8 3.3 control output connection the ssr control output of the controller syl-2352 provides a 12v dc signal that can control up to 5 ssrs in parallel. The relay output of the controller syl-2342 can be used to turn on a contactor or a solenoid valve. It c...

  • Page 3

    Auber instruments www.Auberins.Com 2011.02 p3/8 4.2.2 display change press the set key to change the display mode. The display can be changed between display modes 1 and 2. 4.2.3 manual/automatic mode switch bumpless switching between pid mode and manual mode can be performed by pressing the a/m key...

  • Page 4

    Auber instruments www.Auberins.Com 2011.02 p4/8 the things you should know about alarm 1) absolute alarm and deviation alarm high (or low) limit absolute alarm is set by the specific temperatures that the alarm will be on. Deviation high (or low) alarm is set by how many degrees above (or below) the...

  • Page 5

    Auber instruments 2011.02 p5/8 sn code input device display range (ºc) display range (ºf) 0 k (thermocouple) -50~+1300 -58~2372 1 s(thermocouple) -50~+1700 -58~3092 2 wre (5/26) (thermocouple) 0~2300 32~4172 3 t (thermocouple) -200~350 -328~662 4 e (thermocouple) 0~800 32~1472 5 j (thermocouple) 0~1...

  • Page 6

    Tc auber instruments 2011.02 p6/8 4.17 lock up the settings, field parameter “ep” and parameter “lock” to prevent the operator from changing the settings by accident, you can lock the parameter settings after initial setup. You can select which parameter can be viewed or changed by assigning one of ...

  • Page 7

    Tc auber instruments 2011.02 p7/8 tc n 1 13 14 6 2 7 8 9 10 l 120vac refrigerator fuse syl-2342 3 4 5 bulb + - figure 11. A refrigerator connected to syl-2342 directly this is an example for beer fermentation. The refrigerator is driven by the internal relay of the controller directly. Please note t...

  • Page 8

    Auber instruments 2011.02 p8/8 quick guide for syl-2342, 2352 1. Wiring 1) power to the controller. Connect the 85-260v ac power to terminals 9 and 10. 2) control output connection. Connect terminals 7 and 8 for output. 3) sensor connection. For thermocouples, connect the positive wire to terminal 4...