Audio International AI-LCD68-01-xx Installation And Operation Manual - page 7
AI-LCD68-01-xx
Installation and Operation Manual
Document # 540260, Rev IR, 11/2004
Page 6 of 15
3.3
Cautions and Warnings
3.3.1 It is important to do a pin-to-pin power and ground check on all
connectors. Audio International recommends using an Electrical
Meter set to read Ohms or an Audible Continuity Tester to confirm
that the pins are connected via wiring. Ensure that power and
ground are applied only where specified. Damage to the unit may
result if power or ground is applied to the wrong points.
3.3.2 DO NOT connect or disconnect the monitor while power is applied.
3.3.3 DO NOT remove any factory-installed screws. Damage to the units
may result and void any warranties.
3.3.4 DO NOT expose to moisture.
3.3.5 Maintain an operating temperature of -15
° to +55° C (+5° to +131°
F). Storage temperature must remain between -20
° to 70° C (-4° to
158
° F)
3.3.6 ESD (Electro Static Discharge) guidelines shall be followed.
3.4
Wiring
Requirements
3.4.1 Introduction
The installing agency shall supply and fabricate all external cables
and mating connectors. The length and routing of external cables
should be carefully studied and planned before attempting
installation of the equipment in order to help avoid potential noise
sources and ground loops. Length and routing of external cables
should be considered to avoid possible noise sources and ground
loops. Maintain a minimum clearance of three (3) inches from any
control cable. If wiring is run parallel to combustible fluid or oxygen
lines, maintain a separation of six (6) inches between the lines.