Profesionnal amplifier climax 3200 dsp user manual.
Power supply ensure that the insource voltage (ac outlet) matches the voltage rating of the product. Failure to do so could result in damage to the product and possibly the user. Unplug the product before electrical storms occur and when unused for long periods of time to reduce the risk of electric...
3 1. Introduction ………………………………………………………………………….. 4 2. Mains features ……………...………………………….…………………………… 4 3. Controls ..……………………………….…………..……………………………….. 5 4. Settings and dsp functions ....……………………….………….……………….. 9 5. Remote control ……………………………………………………………………. 12 6. Connections ……..…………………………………...…………...
Introduction 4 thank you for purchasing the audiopole climax 3200 dsp. This class-h dsp amplifier is designed for high power touring or fixed installations. The device delivers 2 x 1600 w rms /4 ohms and 3200 w rms /8 ohms in "bridge” mode. Equipped with a 24-bit dsp, the amplifier handles the funct...
Controls 5 3 a - front panel 1- power power on/off switch. By default, when the device is switched on for the first time, both channels activate in mute mode. To change, refer to page 11, paragraph 3. 2 - output the led brightness is proportional to the output current. It becomes visible when the cu...
Controls 6 3 9 - led informations 10 - edit / mute pressing the button activates the channel in mute mode and turns the red led on. Holding the buttons for more than 3 seconds activates the channel in edit mode allowing the parameter setting. 11 - dsp functions x-over : crossover setting eq : eq set...
12 - power connector cei power socket. Before any connections make sure that the power cable is not damaged. The connection to the mains supply must have an earth connection. The mains voltage supplied must conform with the electrical characteristics of the appliance. 13 - cooling fan vent do not ob...
18 - hpf 1, hpf 2 : channel 1 & 2 high pass filter right middle left 19 - pc input connector the amplifier can be controlled and programmed with a pc iva a rs-485 interface and the dedicated software. The control distance works up to 1000 m. Dsp controls equalizer, crossover, delay, opposite phase, ...
Parameters and dsp settings 9 4 parameter setting pressing the « mute/edit » key for more than three seconds activates the edit mode. Green display of the relevant channel lights up, and relevant channel turns into the parameter setting (channel default setting is « input mute »). Short press a func...
10 f) load load setting configuration previously saved in a memory unit. G) save save up to 30 different setting configurations. To erase a configuration, press save more than 3seconds : 4 parameters and dsp settings.
11 h) system 1 - device id setup 2 - password setting 3 - power on setup (mute) 4 - lcd backlight setup 5 - work mode stereo / parallel / bridge 6 - current program 7 - system information 4 parameters and dsp settings.
12 5 remote control 1 - pc connection climax 3200 dsp use advanced long-distance remote control technology; it can set all the function and control by connection software. Short distance can be control by connecting through usb or rs-485 slot. Rs-485 can control up to 250 amplifiers. Example a (for ...
13 5 remote control example b (up to 250 amplifiers) rs-232 connection.
14 5 remote control example c (up to 250 amplifiers) usb connection usb / rs-485 converter.
15 5 remote control 2 - software a. Display option b. Select display channel c. Signal display d. Mute on/off e. Channel select switching f. Connected products id g. Connection h. Save / read program i. Copy j. Mode (stereo / parallel / bridge) k. Products selection (id) l. Current using program and...
16 5 remote control program after selected, display shows as below: 1. To edit only one configuration, follow this procedure : • press a, edit the configuration • press b or • press e, edit the configuration • press f by default the pc configurations are stored in the directory root 'music '. Files ...
17 5 remote control copy function copy parameters from one channel to an other one mode selection : stereo / parallel / bridge change current device id copy mode device.
18 5 remote control 3 - signal settings a) gain gain adjustment from -59 db to +6 db, ± 0.5 db step. B) delay delay adjustment from 0 to 1000 ms. Value can be displayed in feet (ft) or meter (m). C) polarity polarity adjustment (phase): [+] corresponds to 0°, [-] corresponds to 180°. D) x-over hpf t...
19 remote control 4 - eq settings a) parameter low-shelf or hi-shelf. B) hz: frequency from 20 hz to 20 khz. C) oct: from 0.05 to 3 (parametric filter) / slope: +6 db, +12 db (lo-shelf / hi-shelf). D) db: gain from -20 db to +20 db. E) bypass eq on/off. 5.
20 6 connections 1 - inputs before any connection, turn the amplifier off. Check the operating mode (stereo / parallel / bridge) and adapt the connections of the inputs and outputs accordingly. Pin 1 = ground pin 2 = hot pin 3 = cold 2 - outputs speakon outputs : channel1 : pin 1+ : channel 1 signal...
21 6 connections 3 - modes 2 channels mode (stereo) 2 channels mode (bypass) parallel mono mode (parallel).
22 6 connections bridge mono mode (bridge) 4 - factory settings caution ! Bridge mode impedance must not drop below 8 ohms. Climax 3200 dsp is configured with the following factory rear panel settings: 15 input ground lift 16 gain: -26 db 17 clip limiter: off 18 hpf-1 et hpf-2: off 15 16 17 18 18.
23 7 warranty 9 technical specifications this device is warranted parts and labor against any manufacturing defects for a period of two years from the date of purchase by the first user. Conditions 1. The unit has been installed and implemented by observing the safety instructions in this operating ...
22, rue Édouard buffard, z.A.C. De la charbonnière, montévrain - 77771 marne-la-vallée cedex 4 - france tél : + 33 (0)1 60 54 32 00 - fax : + 33 (0) 1 60 54 31 90 - www.Audiopole.Fr, www.Audiopole-pa.Com.