B&B Electronics iMcV-DS3 Operation Manual

Other manuals for iMcV-DS3: Operation Manual
Manual is about: SNMP-manageable module

Summary of iMcV-DS3

  • Page 1

    Imcv-ds3/e3/sts repeater operation manual.

  • Page 2

    Ii fcc radio frequency interference statement this equipment has been tested and found to comply with the limits for a class a computing device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operate...

  • Page 3

    Iii business, loss of use or of data interruption of business, lost profits or goodwill or other special, incidental, exemplary or consequential damages. B&b electronic shall disregard and not be bound by any representations, warranties or indemnities made by any other person, including without limi...

  • Page 4

    Iv table of contents fcc radio frequency interference statement ............ Ii limited lifetime warranty ............................. Ii about the imcv-ds3/e3/sts .............................. 1 installating an imcv-ds3/e3/sts ........................ 1 configuration instructions ...................

  • Page 5

    1 about the imcv-ds3/e3/sts imcv-ds3/e3/sts is an snmp-manageable module which converts thin coax signals to single-mode or multi-mode fiber signals at a data rate of 45 mbps (ds3), 34 mbps (e3) or 52 mbps (sts). Each imcv-ds3/e3/sts, bnc/fx module includes one pair of bnc connectors and one pair of...

  • Page 6

    2 requirements the imcv-ds3/e3/sts is designed to conform to many ds3/e3/sts-based environments. Make sure that all of the relevant information about the expected installation environment is available before configuring the module. This information includes the following: • distance of the coax run ...

  • Page 7

    3 iview 2 supports the following platforms:  windows 2000  windows xp  windows vista  windows 7 please see the snmp management module installation guide for software configuration options..

  • Page 8

    4 unmanaged modules before installing the module in an unmanaged chassis, including ie-mediachassis series and mediachassis series, manually configure all of the desired dip switch selectable features. In an unmanaged configuration, none of the dip switch settings can be overridden by software. Dip ...

  • Page 9

    5 function switch settings result [(d) = default] loopback (iview 2 configurable) s1-1: off loopback disabled (d) s1-1: on loopback enabled loopback type (iview 2 configurable) s1-2: off coax (d) s1-2: on fiber jitter attenuation (iview 2 configurable) s1-3: off jitter attenuator on receive side s1-...

  • Page 10

    6 this feature can be controlled by snmp management software (iview 2 ) when the imcv-ds3/e3/sts module is installed in a managed chassis..

  • Page 11

    7 loopback type this switch controls which data line is looped back when the loopback dip switch is enabled. The data line loopback selection can be either fiber loopback or coax loopback. By default this feature is set to coax. This feature can be controlled by snmp management software (iview 2 ) w...

  • Page 12

    8 this feature can be controlled by snmp management software (iview 2 ) when the imcv-ds3/e3/sts module is installed in a managed chassis. ** warning ** enabling fiberalert on both of the imcv-ds3/e3/sts modules will cause them both to stop transmitting unrecoverably when a fault occurs. This featur...

  • Page 13

    9 ds3, e3 and sts selection this switch selects the data rate to use on the coax line. The data rate selections available include the following: • 45 mbps (ds3) • 34 mbps (e3) • 52 mbps (sts) by default this feature is set to 45 mbps (ds3). This feature can only be selected by setting the dip switch...

  • Page 14

    10 remote unit this option allows the user to enable remote unit on the module. The remote unit feature is designed to work only as the remote module of the local/remote pairin the required master/slave configuration. With remote unit enabled, the user can easily perform the following: • test the li...

  • Page 15

    11 • redirects the incoming signal back out to the origin while continuing to transmit downstream. • blocks downstream data from arriving on the looped data line. Loopback testing is useful for troubleshooting problems with network connections should they occur. Looping received data back onto the t...

  • Page 16

    12 pseudorandom bit sequence (prbs) testing to test using pseudorandom bit sequence, configure the imcv-ds3/e3/sts modules for no loopback, then configure the transmit data source to “transmit pseudorandom bit sequence.” configure the local device for loopback, conduct the test, then check the pbeo ...

  • Page 17

    13 led operation the imcv-ds3/e3/sts module features several diagnostic leds per port. The led functions are as follows: lpbk no lnk pbeo fa no lnk rm sym leds next to coax (bnc) port glows green when module is in a loopback mode. Glows green when a link is not established. When transmit data source...

  • Page 18

    14 troubleshooting general troubleshooting • during installation, first test the fiber and bnc connections with all troubleshooting features disabled; then enable these features, if desired, just before final installation. This will reduce the features’ interference with testing. • when working with...

  • Page 19

    15 specifications power consumption (typical) 0.550 amps @ 5 v operating temperature +32°f to +122°f (0°c to +50°c) storage temperature 0°f to +160°f (-20°c to +70 c) humidity 5 to 95% (non-condensing); 0 to 10,000 ft. Altitude dimensions 4.19” x .78” x 2.75” (106.4 mm x 19.81 mm x 69.85 mm).

  • Page 20

    16 b&b electronics technical support tel: (800) 346-3119 (in the u.S. And canada) monday-friday, 7:00am-7:00pm cst +353 91 792444 (europe) monday through friday 8:00am - 5:00pm gmt fax: (815) 433-5109 e-mail: support@bb-elec.Com web: www.Bb-elec.Com.

  • Page 21

    17 fiber optic cleaning guidelines fiber optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust, which can obstruct the optic path and cause performance degradation. Good system performance requires clean optics and connector ferrules. 1. Use fiber p...

  • Page 22

    18 electrostatic discharge precautions electrostatic discharge (esd) can cause damage to any product, add-in modules or stand alone units, containing electronic components. Always observe the following precautions when installing or handling these kinds of products 1. Do not remove unit from its pro...

  • Page 23

    19 safety certifications ul/cul: listed to safety of information technology equipment, including electrical business equipment. European directive 2002/96/ec (weee) requires that any equipment that bears this symbol on product or packaging must not be disposed of with unsorted municipal waste. This ...

  • Page 24

    International headquarters b&b electronics 707 dayton road ottawa, il 61350 usa phone (815)433-5100 — general fax (815) 433-5105 website: www.Bb-elec.Com european headquarters b&b electronics westlink commercial park oranmore, co. Galway, ireland phone +353 91-792444 — fax +353 91-79244s5 website: w...