B2 Audio SLD5K Owner's Manual - page 4
4
Panel layout
SLD600
INPUT
BASS BOOST
RCA signal input for Left & Right channel.
Variable signal boost of the BASS FREQ chosen
A minimum of 0.2 v input signal is required for correct
with 0 dB ~ 15 dB.
operation.
POWER & PROTECTION INDICATOR
LPF (LOW PASS FILTER 50 Hz ~250 Hz, 24 dB/oct)
Power LED, blue light shows correct operation,
Adjusts the cut off point for the low pass crossover
Protect LED, red light shows general malfunction, faulty
at the frequency chosen.
connection or thermal protection.
REMOTE LEVEL CONTROL PORT
GAIN (4V~0.2v)
Connection of external signal level control.
Adjusts signal input voltage from the source
CAUTION, the amplifier needs to be gained in accordance
to match the amplifiers input stage.
with the remote to avoid excessive signal boost.
0.2 V ~ 4 V is the operational voltage.
Voltages beyond may cause damage.
boost freq ( 40 hz - 100 hz)
Adjustable
bass
boost
frequency
between
40
~100
Hz.
Subsonic
Use with caution, boosting the wrong frequency
Variable subsonice setting from 10 to 50 Hz.
may conflict with the performance of your enclosure
It is highly recommended to set it according to the
design.
tuning of your subwoofers enclosure to avoid unnecessary
strain to your sound system.
Phase
Shift of the phase to match the delay the subwoofer enclosure
due to position may cause. Adjusting this can improve the audio
response in regards to the midrange speakers.