Baalbaki CS Instruction Manual - page 8
3.3 How to clog the Sieve
The Sieve may be clogged using the Central Shaft Clogging Pin ( no.19 Pic 5 ) .
The consequence of the day to day Centrifugal Juicer use , will be after some time , a
natural wear of some components . Such wearing will produce a residual
accumulation , and may cause the Sieve to stick to the Central Shaft .
To allow to remove the Sieve , a system has been developed to clog the Central Shaft
.
Below we outline the procedure to follow if such problem arises :
1.Switch OFF the machine and unplug it.
2.Turn the Clogging Pin Safety Plate ( no.18 Pic 5 ) upward and press the Central
Shaft Clogging Pin( no.19 Pic 5 ) against the Central Shaft ultil it feels that clogging
pin has entered central shaft hole.
3.Keep the Central Shaft Clogging Pin Plate under pressure , turn the Sieve ( no. 07
Pic 9 ) counterclockwise until it gets blocked. release central shaft clogging pin an a
lift the sieve with your two hands and lift it .
4.Loose the Central Shaft Clogging Pin Plate ( no.19 Pic 5 ) and lower the Clogging
Pin Safety Plate ( no.18 Pic 5 )
IMPORTANT
To keep the centrifugal juicer working for as long time as possible without having to
use the central shaft clogging pin we recommend to keep the central shaft and the
sieve always clean (see Pic.10 Page 16)
3.4 Production
The output in quarts will mainly depend on the kind of product to be processed and on
the operator performance .
3.5 Cleaning
All the moving parts that have been in contact with the product shall be removed and
cleaned .
Below follows the procedure on removing the moving parts :
1.Switch OFF the machine and unplug it .
2.Lose the two Handles , grab the Bowl by the nose and remove the Lid turning it
clockwise .
3.Grab the Sieve with both hands and lift it . If the Sieve does not come out , turn it
counterclockwise and try to lift it again (Pic 2 ) . If no result is obtained , then proceed
as written at item 3.3 " How to clog the Sieve ".
4.Remove the Bowl .
5.Wash with running water all the removed parts .
5
There are some situations in which dropping one glass of water in the feeding throat
with the machine on is enough to clean the sieve, the bowl cover and the bowl.
If that is not enough, we suggest you to follow the cleaning procedures above
.
4.6 Maintenance
4.6.1Dangers
With the machine switched ON any maintenance operation is dangerous .
UNPLUG THE MACHINE FROM ITS SOCKET DURING THE WHOLE
MAINTENANCE OPERATION TIME .
IMPORTANT
Always unplug the machine during emergencies .
4.7 Advices
Electrical or mechanical maintenance shall be made by qualified persons .
The maintenance responsible shall be sure the machine is working in TOTAL
SAFETY conditions .
5 Problem Analysis and Solutions
5.1 Problems Causes and Solutions
The Centrifugal Juicer has been designed to need a minimum maintenance .
However some problems may arise due to normal wear during the machine life .
If some problem arises, check table 2 , where some possible solutions are
recommended .
10