EVAPORATOR SET UP, continued
6. Wrap the TXV and refrigeration solenoid with ESP Heat block (#HB34) or comparable
product. Braze the refrigerant solenoid to the liquid line. Remove the TXV bulk and braze
in the suction line to the line exiting the condenser. Re-attach the bulb when cool.
7. Locate the nearest water supply. Shut off water supply to the line and braze in the
CPS water supply compression adapter. Connect the water filter to the fitting and run
¼” copper from the filter thru the evaporator ceiling opening and cap, and attach to the
water solenoid inlet in each evaporator.
8.
Attach the 1/4” vinyl hose drain tube to the outlet of the green condensate pump.
9.
For indoor applications, run 1/4” vinyl condensate drain tube from the evaporator to
a suitable location
10. Do not replace cover until unit test is complete.