Bacharach 19-9336 Instruction
Combustible Gas Leak Detector
Instruction 19-9336
Rev. 0 – October 2005
Audible Alarm
• Instrument Ready -Slowbeep.Thebeep
rateisaboutoncepersecondwithnogas
detected.
• Combustible Gas Indication -Beepsat
aratethatincreasesalongwiththegas
concentration.
• Sensitivity -Producesanincreasing
frequencytonewhensensitivitychanges
fromlowtohigh,andproducesadecreasing
frequencytonewhensensitivitychanges
fromhightolow.
• Dead Batteries -Highfrequencytone,fol-
lowedbytheinstrumentturningitselfOFF.
• Sensor Error -Rapidlychanginghighand
lowfrequencytones.
Visual Alarm LED
• Power ON -
Rapidly flashes green during warm-
up(approximately60seconds).
• Power OFF -GlowsredjustbeforepowerOFF.
• Instrument Ready -
Slowly flashes green. The
flash rate is about once per second with no gas
detected.
• Combustible Gas Indication -Flashesgreenat
aratethatincreaseswiththegasconcentration.
• Sensitivity Change -Colorchangesfromredto
green.
• Low Battery -Flashesorangeinsteadofgreen
whencheckingforgasleaks.Typically1hour
ofoperationleftafterLEDchangestoorange.
Changebatteriesassoonasconvenient.
• Dead Batteries -Glowsred,followedbythe
instrumentturningitselfOFF.
• Sensor Error -Flashesalternatinggreenandred.
One Button Control
• PressonceforhalfsecondtoturninstrumentON.
• Pressandholdfor2secondstoturninstrumentOFF.
• Doublepresstotogglesensitivitybetweenhighandlow.
Combustibles Sensor
& Sensor Cover
Battery Door
12 Inch
Flexible Probe