Bacharach Fyrite Pro Quick Start Manual

Other manuals for Fyrite Pro: Brochure, Instruction, Instruction
Manual is about: Combustion Gas Analyzer

Summary of Fyrite Pro

  • Page 1

    Fyrite ® pro quick start guide 0024-9396 rev. 8 – may 2010 this guide provides basic operating and maintenance information for fyrite pro model 100/105/110/120/125. Detailed information concerning the analyzer’s operation, set up, calibration, maintenance, and parts list is contained in instruction ...

  • Page 2: Measuring Co

    Instruction 0024-9396 2 fyrite pro quick reference guide 2. Turn on the analyzer by pressing its i/o button and observe that a series of three warm-up screens are displayed. The first screen identifies the model number of the analyzer, the next screen shows the software revision number, while the la...

  • Page 3: Measuring Draft

    Instruction 0024-9396 3 fyrite pro quick reference guide 2. For the model 100/105, the co or co & draft screen should al- ready be displayed. For the model 120/125, push the enter button to display the co & o 2 screen. Model 100 model 105 model 120/125 3. Insert the analyzer’s probe into the area to...

  • Page 4: The Model 110/120/125

    Instruction 0024-9396 4 fyrite pro quick reference guide performing a combustion test using the model 110/120/125 important: the probe must be at room temperature before performing the following steps. 1. Perform one of the following: • model 110/120 – before turning on the analyzer, its probe must ...

  • Page 5

    Instruction 0024-9396 5 fyrite pro quick reference guide atmospheric burner or gravity vented forced air hot water tank 5. Insert the probe into the flue-gas stream of the appliance being tested as described below: forced air furnace – when testing atmospheric burner or grav- ity vented, forced air ...

  • Page 6

    Instruction 0024-9396 6 fyrite pro quick reference guide 90% eff. Condensing furnace/boiler atmospheric or gravity vented boiler 80% eff. Fan assist or power vented furnace/boiler.

  • Page 7

    Instruction 0024-9396 7 fyrite pro quick reference guide 6. After turning on the analyzer and selecting the appropriate fuel, press the or button to display the stack temperature & effi- ciency screen. 7. Position the probe in the flue-gas stream to obtain the hottest “stack” reading. Lo cat ing the...

  • Page 8: Run Mode Screens

    Instruction 0024-9396 8 fyrite pro quick reference guide run mode screens figures 2a thru 2e show the order in which the screens are displayed by pressing the enter and buttons after the analyzer warms-up and enters its run mode. The top screen in each figure is the one that appears immediately afte...

  • Page 9

    Instruction 0024-9396 9 fyrite pro quick reference guide fuel select: f1 = natural gas f2 = oil #2 f3 = lpg f4 = kerosene o 2 ambient / combustion air temperature stack temperature & efficiency co 2 & excess air figure 2c. Model 110 run mode screens.

  • Page 10

    Instruction 0024-9396 10 fyrite pro quick reference guide figure 2d. Model 120 run mode screens fuel select: f1 = natural gas f2 = oil #2 f3 = lpg f4 = kerosene co & o 2 co air free ambient / combustion air temperature stack temperature & efficiency co 2 & excess air.

  • Page 11

    Instruction 0024-9396 11 fyrite pro quick reference guide figure 2e. Model 125 run mode screens fuel select: f1 = natural gas f2 = oil #2 f3 = lpg f4 = kerosene co & o 2 co air free ambient / combustion air temperature temperature differential stack temperature & efficiency co 2 & excess air co & dr...

  • Page 12: Operating Tips

    Instruction 0024-9396 12 fyrite pro quick reference guide operating tips • when an analyzer is brought in from a cold vehicle, let it warm up slowly to minimize condensation. Temperatures below freezing will not damage the analyzer; however, bringing a cold analyzer into a warm, humid environment ma...

  • Page 13: Co Channel Zero

    Instruction 0024-9396 13 fyrite pro quick reference guide co channel zero (model 100/105/120/125) if the co channel is set up for manual zero (refer to sec tion 3.5.3 in instruction 24-9395), and if the co screen shows a value other than zero when sampling fresh air, then zero the co channel as foll...

  • Page 14: Saving Test Data In Memory

    Instruction 0024-9396 14 fyrite pro quick reference guide saving test data in memory (model 105/110/120/125) up to 10 individual sets of test data can be saved in memory as follows: note: when memory is full, the next reading saved will over- write the oldest reading. Note: the analyzer’s setup info...

  • Page 15: Clearing Saved Test Data

    Instruction 0024-9396 15 fyrite pro quick reference guide 2. Press the or button until the open screen is displayed, and then press enter to open the memory locations for viewing. The number shown in the second screen represents the most recent memory location where data was stored. 3. Press the or ...

  • Page 16: Printing Test Data

    Instruction 0024-9396 16 fyrite pro quick reference guide printing test data tip: to avoid printing errors, it is important to select the correct protocol per section 3.5.8 in instruction 0024-9395 before saving data. Turn on the printer. Refer to the printer’s instruction manual for detailed operat...

  • Page 17

    Instruction 0024-9396 17 fyrite pro quick reference guide figure 3. Printer alignment & sample printout b a c h a r a c h , i n c . F y r i t e p r o a n a l y z e r = = = = = = = = = = = = = = = = = = = = = = = d a t e : 2 9 / 1 0 / 2 0 0 3 t i m e : 1 4 : 4 5 f u e l : ( f 1 ) q a 1 5 . 9 % e t a ...

  • Page 18: Resetting The Microprocessor

    Instruction 0024-9396 18 fyrite pro quick reference guide turning off the analyzer & co purge press the i/o button to turn off the analyzer. The unit will count down from 5 before turning off, thus allowing time for the operator to abort the turn off process by press ing the enter button. If a high ...

  • Page 19

    Instruction 0024-9396 19 fyrite pro quick reference guide replace the filter element when dirty. Material required: • filter element, p/n 0007-1644 • small flat blade screwdriver procedure: 1. Disassemble the trap (see figure 4 or 5). 2. Remove and discard old filter. 3. Install new filter and reass...

  • Page 20

    World headquarters 621 hunt valley circle, new kensington, pa 15068 ph: 724-334-5000 • fax: 724-334-5001 • toll free: 800-736-4666 web site: www.Mybacharach.Com • e-mail: help@mybacharach.Com printed in u.S.A..