Bacharach PUR-CHEK Instruction - page 6
Pur•Chek
™
Instruction 2100-9000
2
1.2.2 General Warnings & Cautions
•
Always inspect the sample hose before each use. Replace the hose if it appears cracked,
frayed, obstructed or fouled with oil.
•
ALWAYS turn the compressor off before connecting the instrument to an air conditioning
system.
•
Always wear eye and skin protection when working with refrigerants. Escaping refrigerant
vapors will present a freezing danger.
•
To reduce the risk of electrical shock, do not disassemble the instrument; do not use the instru-
ment in wet or damp areas.
•
DO NOT direct refrigerant vapors venting from hoses towards the skin.
•
DO NOT disassemble the instrument. There are no serviceable components internal to the
instrument and disassembly will void the warranty.
•
ALWAYS place the Identifi er on a fl at and sturdy surface.
•
DO NOT utilize any other hose other than those supplied with the instrument. The use of other
hose types will introduce errors into the refrigerant analysis and instrument calibration.
•
ALWAYS verify that the refrigerant to be tested does not contain or will not emit heavy loads of
oil or liquid.
•
NEVER admit any sample into the instrument at pressures in excess of 500 psig.
1.3 Features and Capabilities
The Pur•Chek
™
HVAC Advanced Refrigerant Identifi er is the most advanced portable instrument ever manu-
factured for determining the purity of gaseous refrigerants for the HVAC-R market. Features of the Pur•Chek™
include:
•
Stable 4-gas infrared sensor technology
•
Advanced ergonomic design
•
Rugged rubberized hand grips
•
Large graphic display with on-screen instructions
•
Ultra fast 60-second test time
•
‘Blend-Chek’ software to identify the presence of R410A
•
Built in printer option for instant analysis report
•
Internal, rechargeable batter option for cordless operation in any location
•
Hard shell carry/storage case
1.4 Pur•Chek™ Models and Contents
Model Name
Part Number
Contents
Pur•Chek™
2100-8001
Pur•Chek™ ............................................ 2100-8001
1/4” Flare Sampling Hose Assembly ...... 2100-0005
AC Adapter ............................................. 2100-0004
Instruction Manual .................................. 2100-9000
All contained in a hard shell storage/carrying case.
Pur•Chek w/ Printer
2100-8002
Pur•Chek™ w/ Printer ............................ 2100-8002
1/4” Flare Sampling Hose Assembly ...... 2100-0005
AC Adapter ............................................. 2100-0004
Printer Paper (1 Roll) .............................. 2100-0003
Instruction Manual .................................. 2100-9000
All contained in a hard shell storage/carrying case.